NY EnergyConservationConstructionCode 07 2007
$18.42
Energy Conservation Construction Code of New York State
Published By | Publication Date | Number of Pages |
NY | 2007 | 82 |
This publication is based on the 2003 International Energy Conservation Code®. It addresses the design of energy-efficient building envelopes and the installation of energy-efficient mechanical, lighting, and power systems through requirements emphasizing performance. This comprehensive code establishes minimum regulations for energy-efficient buildings using prescriptive and performance-related provisions. It makes possible the use of new materials and innovative techniques that conserve energy.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE 2007 |
2 | COPYRIGHT © 2007 |
3 | ACKNOWLEDGMENTS |
5 | TABLE OF CONTENTS |
7 | CHAPTER 1 ADMINISTRATION AND ENFORCEMENT SECTION 101 SCOPE AND GENERAL REQUIREMENTS |
8 | SECTION 102 MATERIALS, SYSTEMS AND EQUIPMENT TABLE 102.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS |
9 | TABLE 102.1.3(2) DEFAULT DOOR U-FACTORS TABLE 102.1.3(3) DEFAULT GLAZED FENESTRATION SHGC SECTION 103 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS SECTION 104 CONSTRUCTION DOCUMENTS SECTION 105 ADMINISTRATION AND ENFORCEMENT |
10 | SECTION 106 VALIDITY SECTION 107 REFERENCED STANDARDS |
11 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
15 | CHAPTER 3 CLIMATE ZONES SECTION 301 CLIMATE ZONES TABLE 301.1 NEW YORK STATE RESIDENTIAL AND COMMERCIAL CLIMATE ZONES SECTION 302 DESIGN CONDITIONS |
16 | TABLE 301.1—continued NEW YORK STATE RESIDENTIAL AND COMMERCIAL CLIMATE ZONES |
17 | TABLE 301.1—continued NEW YORK STATE RESIDENTIAL AND COMMERCIAL CLIMATE ZONES |
19 | CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY SECTION 401 GENERAL SECTION 402 BUILDING THERMAL ENVELOPE TABLE 402.1(1) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa TABLE 402.1(2 )ALTERNATIVE INSULATION REQUIREMENTS BY COMPONENTa See Section 402.1, Exception 3 |
20 | TABLE 402.1.2 EQUIVALENT U-FACTORSa TABLE 402.1.4 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT FOR RESIDENCES USING ELECTRIC RESISTANCE HEATING |
21 | TABLE 402.2.4 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) |
22 | SECTION 403 SYSTEMS |
23 | TABLE 403.7 OPTIONAL MECHANICAL EQUIPMENT EFFICIENCY REQUIREMENTS SECTION 404 SIMULATED PERFORMANCE ALTERNATIVE |
24 | TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
25 | TABLE 404.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
26 | TABLE 404.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS TABLE 404.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa |
29 | CHAPTER 5 RESERVED |
31 | CHAPTER 6 RESERVED |
33 | CHAPTER 7 RESERVED |
35 | CHAPTER 8 BUILDING DESIGN FOR COMMERCIAL BUILDINGS SECTION 801 GENERAL SECTION 802 BUILDING ENVELOPE REQUIREMENTS |
36 | TABLE 802.2(1) BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 10b |
37 | TABLE 802.2(1)—continued BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 10b |
38 | TABLE 802.2(2) BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 11b |
39 | TABLE 802.2(2)—continued BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 11b |
40 | TABLE 802.2(3) BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 12b |
41 | TABLE 802.2(3)—continued BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 12b |
42 | TABLE 802.2(4) BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 13a |
43 | TABLE 802.2(4)—continued BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 13a |
44 | TABLE 802.2(5) BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 14a |
45 | TABLE 802.2(5)—continued BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 14a |
46 | TABLE 802.2(6) BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 1 |
47 | TABLE 802.2(6)—continued BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 15 |
48 | TABLE 802.2(7) BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 16 |
49 | TABLE 802.2(7)—continued BUILDING ENVELOPE REQUIREMENTSa through e – CLIMATE ZONE 16 |
50 | (EQUATION 8-1) |
51 | SECTION 803 BUILDING MECHANICAL SYSTEMS |
53 | TABLE 803.2.2 (1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
54 | TABLE 803.2.2(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
55 | TABLE 803.2.2(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS TABLE 803.2.2(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
56 | TABLE 803.2.2(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS TABLE 803.2.6 MINIMUM EQUIPMENT EFFICIENCY ECONOMIZER EXCEPTION |
57 | TABLE 803.3.2(1) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS TABLE 803.3.2(2) WATER CHILLING PACKAGES, MINIMUM EFFICIENCY REQUIREMENTS |
58 | TABLE 803.3.2(3) COPS AND IPLVS FOR NONSTANDARD CENTRIFUGAL CHILLERS < 150 TONS |
59 | TABLE 803.3.2(4) COPs AND IPLVS FOR NONSTANDARD CENTRIFUGAL CHILLERS 150 TONS, 300 TONS |
60 | TABLE 803.3.2(5) COPS AND IPLVS FOR NONSTANDARD CENTRIFUGAL CHILLERS 300 TONS |
61 | TABLE 803.3.2(6) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT |
63 | (EQUATION 8-2) TABLE 803.3.7MINIMUM PIPE INSULATIONa(thickness in inches) |
64 | SECTION 804 SERVICE WATER HEATING SECTION 805 ELECTRICAL POWER AND LIGHTING SYSTEMS |
65 | TABLE 804.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
67 | SECTION 806 TOTAL BUILDING PERFORMANCE |
68 | TABLE 805.5.2 INTERIOR LIGHTING POWER |
69 | TABLE 805.6.1 NEMA CLASS 1 EFFICIENCY LEVELS FOR LIQUID-FILLED DISTRIBUTION TRANSFORMERS TABLE 805.6.2 NEMA CLASS 1 EFFICIENCY LEVELS FOR DRY-TYPE DISTRIBUTION TRANSFORMERS |
71 | CHAPTER 9 RESERVED |
73 | CHAPTER 10 REFERENCED STANDARDS AAMA AMCA ANSI |
74 | ARI ASHRAE ASME ASTM |
75 | CTI DOE HI ICC IESNA |
76 | NFRC SMACNA UL WDMA |
77 | INDEX |