{"id":7277,"date":"2024-10-16T19:02:59","date_gmt":"2024-10-16T19:02:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e1473\/"},"modified":"2024-10-24T10:50:23","modified_gmt":"2024-10-24T10:50:23","slug":"astm-e1473","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e1473\/","title":{"rendered":"ASTM-E1473"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1 These test methods describe the chemical analysis of nickel, cobalt, and high-temperature alloys having chemical compositions within the following limits:<\/p>\n 1.2 The test methods in this standard are contained in the sections indicated as follows:<\/p>\n 1.3 Methods for the determination of several elements not included in these test methods can be found in Test Methods E 30, E 76, and E 1019.<\/p>\n 1.4 Some of the concentration ranges given in 1.1 are too broad to be covered by a single method, and therefore, these test methods contain multiple methods for some elements. The user must select the proper test method by matching the information given in the scope and interference sections of each test method with the composition of the alloy to be analyzed.<\/p>\n 1.5 The values stated in SI units are to be regarded as standard. In some cases, exceptions allowed in Practice E 380 are also used.<\/p>\n 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7 and in 13.4, 29.1, 66.3, 123.5, 124.14, 139.4, 139.5, 147.5, and 147.6.<\/span><\/span><\/p>\n 8.1 This test method covers the determination of manganese in concentrations from 0.05 % to 2.00 %.<\/p>\n 18.1 This test method covers the determination of sulfur in concentrations from 0.006 % to 0.1 %.<\/p>\n 27.1 This test method covers the determination of silicon in concentrations from 0.05 % to 5.00 % in alloys containing not more than 0.1 % boron.<\/p>\n 34.1 This test method covers the determination of cobalt in concentrations from 2 % to 75 %.<\/p>\n 42.1 This test method covers the determination of cobalt in concentrations from 0.10 % to 5.0 %.<\/p>\n 52.1 This test method covers the determination of copper in concentrations from 0.010 % to 1.50 %.<\/p>\n 62.1 This test method covers the determination of total aluminum in concentrations from 0.20 % to 7.00 %.<\/p>\n 70.1 This test method covers the determination of nickel in concentrations from 0.1 % to 84.0 %.<\/p>\n 78.1 This test method covers the determination of tin in the range from 0.002 % to 0.10 %.<\/p>\n 88.1 This test method covers the determination of molybdenum in concentrations from 0.01 % to 1.50 %.<\/p>\n 100.1 This test method covers the determination of chromium in concentrations from 0.018 % to 1.00 %.<\/p>\n 110.1 This test method covers the determination of chromium in concentrations from 0.10 % to 33.00 %.<\/p>\n 119.1 This test method covers the determination of molybdenum in concentrations from 1.5 % to 30 %.<\/p>\n 127.1 This test method covers the determination of iron in concentrations from 1.0 % to 50.0 %.<\/p>\n 135.1 This test method covers the determination of niobium (columbium) in concentrations from 0.5 % to 6.0 %.<\/p>\n 143.1 This test method covers the determination of tantalum in concentrations from 0.03 % to 1.0 %.<\/p>\n Keywords<\/strong><\/p>\n aluminum; chromium; cobalt; cobalt-base alloys; copper; high temperature alloys; iron; manganese; molybdenum; nickel; nickel-base alloys; niobium; silicon; sulfur; tantalum; tin; Aluminum content–Ni\/Ni alloys; Chemical analysis–metals\/alloys; Chromium content–metals\/alloys; Chromium content–Ni\/Ni alloys; Cobalt content–Ni\/Ni alloys; Nickel content–Ni\/Ni alloys; High-temperature service applications–nickel; Iron content–Ni\/Ni alloys; Manganese content–metals\/alloys; Manganese content–Ni\/Ni alloys; Molybdenum content–metals\/alloys; Molybdenum content–Ni\/Ni alloys; Nickel content–miscellaneous metals\/alloys; Silicon content–metals\/alloys; Silicon content–Ni\/Ni alloys; Tantalum (Ta) content–metals\/alloys; Spectrophotometry–atomic absorption; Sulfur–metals\/alloys; Sulfur–Ni\/Ni alloys; Tin content–metals\/alloys; Tin content–Ni\/Ni alloys; Aluminum content; Cobalt alloys; Gravimetric determination; High-temperature alloys; Ion exchange materials\/applications; Nickel alloys (chemical analysis); Photometry; Titration<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 77.120.40 (Nickel, chromium and their alloys)<\/p>\n DOI:<\/strong> 10.1520\/E1473-09<\/p>\n<\/div>\n E1473-09 Standard Test Methods for Chemical Analysis of Nickel, Cobalt, and High-Temperature Alloys<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope <\/td>\n<\/tr>\n \n 2<\/td>\n Referenced Documents
Terminology
Significance and Use
Apparatus, Reagents, and Instrumental Practice
Interlaboratory Studies and Rounding Calculated Values
Hazards
Scope
Summary of Test Method
Concentration Range <\/td>\n<\/tr>\n\n 3<\/td>\n Stability of Color
Interferences
Reagents
Preparation of Calibration Curve
Procedure <\/td>\n<\/tr>\n\n 4<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Apparatus
TABLE 1 <\/td>\n<\/tr>\n\n 5<\/td>\n TABLE 2
FIG. 1 <\/td>\n<\/tr>\n\n 6<\/td>\n Reagents
Calibration
Procedure <\/td>\n<\/tr>\n\n 7<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Reagents
TABLE 4 <\/td>\n<\/tr>\n\n 8<\/td>\n Procedure
Calculation
Precision and Bias <\/td>\n<\/tr>\n\n 9<\/td>\n Scope
Summary of Test Method
Interferences
Apparatus
Reagents <\/td>\n<\/tr>\n\n 10<\/td>\n Procedure
Calculation <\/td>\n<\/tr>\n\n 11<\/td>\n Precision and Bias
Scope
Summary of Test Method
Concentration Range
Stability of Color
Interferences
Reagents
Preparation of Calibration Curve
TABLE 5 <\/td>\n<\/tr>\n\n 12<\/td>\n Procedure
Calculation
Precision and Bias
Scope
Summary of Test Method
Concentration Range
TABLE 6 <\/td>\n<\/tr>\n\n 13<\/td>\n Stability of Color
Interferences
Reagents
Preparation of Calibration Curve
Procedure <\/td>\n<\/tr>\n\n 14<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Apparatus
TABLE 7
FIG. 2 <\/td>\n<\/tr>\n\n 15<\/td>\n Reagents
Procedure <\/td>\n<\/tr>\n\n 16<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Apparatus
TABLE 8 <\/td>\n<\/tr>\n\n 17<\/td>\n Reagents
Procedure <\/td>\n<\/tr>\n\n 18<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Concentration Range
Interferences
TABLE 9 <\/td>\n<\/tr>\n\n 19<\/td>\n Apparatus
Reagents
Preparation of Calibration Curve
Procedure <\/td>\n<\/tr>\n\n 20<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Concentration Range
Stability of Color
Interferences
TABLE 10 <\/td>\n<\/tr>\n\n 21<\/td>\n Reagents
Preparation of Calibration Curve for Concentrations from 0.01 % to 0.05 %
Preparation of Calibration Curve for Concentrations from 0.05 % to 0.55 % <\/td>\n<\/tr>\n\n 22<\/td>\n Preparation of Calibration Curve for Concentrations from 0.40 % to 1.50 %
Procedure <\/td>\n<\/tr>\n\n 23<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Concentration Range
Interferences
Apparatus
Reagents
Preparation of Calibration Curves
TABLE 11 <\/td>\n<\/tr>\n\n 24<\/td>\n Procedure <\/td>\n<\/tr>\n \n 25<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Apparatus
Reagents
TABLE 12 <\/td>\n<\/tr>\n\n 26<\/td>\n Standardization of Ferrous Ammonium Sulfate Solution <\/td>\n<\/tr>\n \n 27<\/td>\n Procedure <\/td>\n<\/tr>\n \n 28<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Apparatus
Reagents
TABLE 13 <\/td>\n<\/tr>\n\n 29<\/td>\n Procedure <\/td>\n<\/tr>\n \n 30<\/td>\n Calculation
Precision and Bias <\/td>\n<\/tr>\n\n 31<\/td>\n Scope
Summary of Test Method
Interferences
Apparatus
Reagents
Procedure
TABLE 14 <\/td>\n<\/tr>\n\n 32<\/td>\n Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Apparatus
Reagents
TABLE 15 <\/td>\n<\/tr>\n\n 33<\/td>\n Procedure <\/td>\n<\/tr>\n \n 34<\/td>\n Calculation
Precision and Bias
TABLE 16 <\/td>\n<\/tr>\n\n 35<\/td>\n Scope
Summary of Test Method
Interferences
Apparatus
Reagents
TABLE 3 <\/td>\n<\/tr>\n\n 36<\/td>\n Preparation of Calibration Curve
Procedure <\/td>\n<\/tr>\n\n 38<\/td>\n Calculation
Precision and Bias
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2009<\/td>\n 38<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":7278,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1103,2637],"product_tag":[],"class_list":{"0":"post-7277","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-77-120-40","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/7277","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/7278"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=7277"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=7277"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=7277"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}