{"id":26065,"date":"2024-10-17T02:26:38","date_gmt":"2024-10-17T02:26:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/mi-mechanicalcode-09-2009\/"},"modified":"2024-10-24T13:44:10","modified_gmt":"2024-10-24T13:44:10","slug":"mi-mechanicalcode-09-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/mi\/mi-mechanicalcode-09-2009\/","title":{"rendered":"MI MechanicalCode 09 2009"},"content":{"rendered":"
This is a fully integrated custom code based on the 2009 International Mechanical Code\u00ae<\/em>(IMC\u00ae). Establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions.<\/span><\/p>\n Michigan Mechanical Code<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n 2009 MICHIGAN MECHANICAL CODE <\/td>\n<\/tr>\n \n 3<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 4<\/td>\n COPYRIGHT <\/td>\n<\/tr>\n \n 5<\/td>\n PREFACE <\/td>\n<\/tr>\n \n 7<\/td>\n SAMPLE ORDINANCE <\/td>\n<\/tr>\n \n 9<\/td>\n TABLE OF CONTENTS <\/td>\n<\/tr>\n \n 13<\/td>\n CHAPTER 1 – SCOPE AND ADMINISTRATION
PART I\u2014SCOPE AND APPLICATION
SECTION 101 – GENERAL
SECTION 102 – APPLICABILITY <\/td>\n<\/tr>\n\n 14<\/td>\n PART 2\u2014ADMINISTRATION AND ENFORCEMENT
SECTION 103 – DEPARTMENT OF MECHANICAL INSPECTION
SECTION 104 – DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 – APPROVAL <\/td>\n<\/tr>\n\n 15<\/td>\n SECTION 106 – PERMITS <\/td>\n<\/tr>\n \n 17<\/td>\n SECTION 107 – INSPECTIONS AND TESTING <\/td>\n<\/tr>\n \n 18<\/td>\n SECTION 108 – VIOLATIONS <\/td>\n<\/tr>\n \n 19<\/td>\n SECTION 109 – MEANS OF APPEAL
SECTION 110 – TEMPORARY EQUIPMENT, SYSTEMS AND USES <\/td>\n<\/tr>\n\n 21<\/td>\n CHAPTER 2 – DEFINITIONS
SECTION 201 – GENERAL
SECTION 202 – GENERAL DEFINITIONS <\/td>\n<\/tr>\n\n 33<\/td>\n CHAPTER 3 – GENERAL REGULATIONS
SECTION 301 – GENERAL <\/td>\n<\/tr>\n\n 34<\/td>\n SECTION 302 – PROTECTION OF STRUCTURE <\/td>\n<\/tr>\n \n 35<\/td>\n SECTION 303 – EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 – INSTALLATION <\/td>\n<\/tr>\n\n 37<\/td>\n SECTION 305 – PIPING SUPPORT
TABLE 305.4 – PIPING SUPPORT SPACING
SECTION 306 – ACCESS AND SERVICE SPACE <\/td>\n<\/tr>\n\n 39<\/td>\n SECTION 307 – CONDENSATE DISPOSAL
TABLE 307.2.2 – CONDENSATE DRAIN SIZING <\/td>\n<\/tr>\n\n 40<\/td>\n SECTION 308 – CLEARANCE REDUCTION
SECTION 309 – TEMPERATURE CONTROL
SECTION 310 – EXPLOSION CONTROL
SECTION 311 – SMOKE AND HEAT VENTS <\/td>\n<\/tr>\n\n 41<\/td>\n TABLE 308.6 – CLEARANCE REDUCTION METHODS
SECTION 312 – HEATING AND COOLING LOAD CALCULATIONS <\/td>\n<\/tr>\n\n 43<\/td>\n CHAPTER 4 – VENTILATION
SECTION 401 – GENERAL
TABLE 401.5 – OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS
SECTION 402 – NATURAL VENTILATION <\/td>\n<\/tr>\n\n 44<\/td>\n SECTION 403 – MECHANICAL VENTILATION
EQUATION 4-1 <\/td>\n<\/tr>\n\n 45<\/td>\n TABLE 403.3 – MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n \n 46<\/td>\n TABLE 403.3\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n \n 47<\/td>\n TABLE 403.3\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n \n 48<\/td>\n TABLE 403.3.1.2 – ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5
TABLE 403.3.2.3.2 – SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7 <\/td>\n<\/tr>\n\n 49<\/td>\n EQUATION 4-8
SECTION 404 – ENCLOSED PARKING GARAGES
SECTION 405 – SYSTEMS CONTROL
SECTION 406 – VENTILATION OF UNINHABITED SPACES <\/td>\n<\/tr>\n\n 51<\/td>\n CHAPTER 5 – EXHAUST SYSTEMS
SECTION 501 – GENERAL
SECTION 502 – REQUIRED SYSTEMS <\/td>\n<\/tr>\n\n 52<\/td>\n EQUATION 5-1 <\/td>\n<\/tr>\n \n 58<\/td>\n SECTION 503 – MOTORS AND FANS
SECTION 504 – CLOTHES DRYER EXHAUST <\/td>\n<\/tr>\n\n 59<\/td>\n TABLE 504.6.4.1 – DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
SECTION 505 – DOMESTIC KITCHEN EXHAUST EQUIPMENT <\/td>\n<\/tr>\n\n 60<\/td>\n SECTION 506 – COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT <\/td>\n<\/tr>\n \n 63<\/td>\n SECTION 507 – COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n \n 65<\/td>\n TABLE 507.11 – MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE <\/td>\n<\/tr>\n \n 66<\/td>\n SECTION 508 – COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 – FIRE SUPPRESSION SYSTEMS
SECTION 510 – HAZARDOUS EXHAUST SYSTEMS <\/td>\n<\/tr>\n\n 68<\/td>\n TABLE 510.8 – MINIMUM DUCT THICKNESS
TABLE 510.8.2 – CLEARANCE TO COMBUSTIBLES
SECTION 511 – DUST, STOCK AND REFUSE CONVEYING SYSTEMS <\/td>\n<\/tr>\n\n 69<\/td>\n TABLE 511.2 – CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 – SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 – SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n\n 71<\/td>\n EQUATION 5-2
EQUATION 5-3
EQUATION 5-4 <\/td>\n<\/tr>\n\n 73<\/td>\n SECTION 514 – ENERGY RECOVERY VENTILATION SYSTEMS <\/td>\n<\/tr>\n \n 75<\/td>\n CHAPTER 6 – DUCT SYSTEMS
SECTION 601 – GENERAL
SECTION 602 – PLENUMS <\/td>\n<\/tr>\n\n 77<\/td>\n SECTION 603 – DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.4 – DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS <\/td>\n<\/tr>\n\n 79<\/td>\n SECTION 604 – INSULATION
SECTION 605 – AIR FILTERS
SECTION 606 – SMOKE DETECTION SYSTEMS CONTROL <\/td>\n<\/tr>\n\n 80<\/td>\n SECTION 607 – DUCT AND TRANSFER OPENINGS <\/td>\n<\/tr>\n \n 81<\/td>\n TABLE 607.3.2.1 – FIRE DAMPER RATING <\/td>\n<\/tr>\n \n 85<\/td>\n CHAPTER 7 – COMBUSTION AIR
SECTION 701 – GENERAL <\/td>\n<\/tr>\n\n 87<\/td>\n CHAPTER 8 – CHIMNEYS AND VENTS
SECTION 801 – GENERAL <\/td>\n<\/tr>\n\n 88<\/td>\n SECTION 802 – VENTS
TABLE 802.2 – VENT APPLICATION <\/td>\n<\/tr>\n\n 89<\/td>\n SECTION 803 – CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FO RMEDIUM- AND HIGH-HEAT APPLIANCES <\/td>\n<\/tr>\n\n 90<\/td>\n TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 – DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS <\/td>\n<\/tr>\n\n 91<\/td>\n SECTION 805 – FACTORY-BUILT CHIMNEYS <\/td>\n<\/tr>\n \n 92<\/td>\n SECTION 806 – METAL CHIMNEYS <\/td>\n<\/tr>\n \n 93<\/td>\n CHAPTER 9 – SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 – GENERAL
SECTION 902 – MASONRY FIREPLACES
SECTION 903 – FACTORY-BUILT FIREPL
SECTION 904 – PELLET FUEL-BURNING APPLIANCES
SECTION 905 – FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 – FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 – INCINERATORS AND CREMATORIES
SECTION 908 – COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS <\/td>\n<\/tr>\n\n 94<\/td>\n SECTION 909 – VENTED WALL FURNACES
SECTION 910 – FLOOR FURNACES
SECTION 911 – DUCT FURNACES
SECTION 912 – INFRARED RADIANT HEATERS
SECTION 913 – CLOTHES DRYERS <\/td>\n<\/tr>\n\n 95<\/td>\n SECTION 914 – SAUNA HEATERS
SECTION 915 – ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 – POOL AND SPA HEATERS
SECTION 917 – COOKING APPLIANCES
SECTION 918 – FORCED-AIR WARM-AIR FURNACES <\/td>\n<\/tr>\n\n 96<\/td>\n SECTION 919 – CONVERSION BURNERS
SECTION 920 – UNIT HEATERS <\/td>\n<\/tr>\n\n 97<\/td>\n SECTION 921 – VENTED ROOM HEATERS
SECTION 922 – KEROSENE AND OIL-FIRED STOVES
SECTION 923 – SMALL CERAMIC KILNS
SECTION 924 – STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 – MASONRY HEATERS
SECTION 926 – GASEOUS HYDROGEN SYSTEMS
SECTION 927 – HEAT RECOVERY VENTILATORS
SECTION 928 – SOLID FUEL HYDRONIC HEATERS <\/td>\n<\/tr>\n\n 99<\/td>\n CHAPTER 10 – BOILERS,WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 – GENERAL
SECTION 1002 – WATER HEATERS
SECTION 1003 – PRESSURE VESSELS
SECTION 1004 – BOILERS <\/td>\n<\/tr>\n\n 100<\/td>\n SECTION 1005 – BOILER CONNECTIONS
SECTION 1006 – SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS <\/td>\n<\/tr>\n\n 101<\/td>\n SECTION 1007 – BOILER LOW-WATER CUTOFF
SECTION 1008 – STEAM BLOWOFF VALVE
SECTION 1009 – HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
SECTION 1010 – GAUGES <\/td>\n<\/tr>\n\n 103<\/td>\n CHAPTER 11 – REFRIGERATION
SECTION 1101 – GENERAL
SECTION 1102 – SYSTEM REQUIREMENTS <\/td>\n<\/tr>\n\n 104<\/td>\n SECTION 1103 – REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 – SYSTEM APPLICATION REQUIREMENTS <\/td>\n<\/tr>\n\n 105<\/td>\n TABLE 1103.1 – REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n \n 106<\/td>\n TABLE 1103.1 – REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n \n 107<\/td>\n TABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n \n 108<\/td>\n TABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n \n 109<\/td>\n TABLE 1104.3.2 – MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS <\/td>\n<\/tr>\n \n 110<\/td>\n SECTION 1105 – MACHINERY ROOM, GENERAL REQUIREMENTS
EQUATION 11-1 <\/td>\n<\/tr>\n\n 111<\/td>\n EQUATION 11-2
SECTION 1106 – MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 – REFRIGERANT PIPING <\/td>\n<\/tr>\n\n 113<\/td>\n SECTION 1108 – FIELD TEST
SECTION 1109 – PERIODIC TESTING <\/td>\n<\/tr>\n\n 115<\/td>\n CHAPTER 12 – HYDRONIC PIPING
SECTION 1201 – GENERAL
SECTION 1202 – MATERIAL
TABLE 1202.4 – HYDRONIC PIPE
TABLE 1202.4\u2014continued HYDRONIC PIPE
TABLE 1202.5 – HYDRONIC PIPE FITTINGS <\/td>\n<\/tr>\n\n 116<\/td>\n SECTION 1203 – JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n \n 117<\/td>\n SECTION 1204 – PIPE INSULATION <\/td>\n<\/tr>\n \n 118<\/td>\n SECTION 1205 – VALVES
SECTION 1206 – PIPING INSTALLATION
SECTION 1207 – TRANSFER FLUID
SECTION 1208 – TESTS <\/td>\n<\/tr>\n\n 119<\/td>\n SECTION 1209 – EMBEDDED PIPING <\/td>\n<\/tr>\n \n 121<\/td>\n CHAPTER 13 – FUEL OIL PIPING AND STORAGE
SECTION 1301 – GENERAL
SECTION 1302 – MATERIAL
TABLE 1302.3 – FUEL OIL PIPING
SECTION 1303 – JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n\n 122<\/td>\n SECTION 1304 – PIPING SUPPORT
SECTION 1305 – FUEL OIL SYSTEM INSTALLATION <\/td>\n<\/tr>\n\n 123<\/td>\n SECTION 1306 – OIL GAUGING
SECTION 1307 – FUEL OIL VALVES
SECTION 1308 – TESTING <\/td>\n<\/tr>\n\n 125<\/td>\n CHAPTER 14 – SOLAR SYSTEMS
SECTION 1401 – GENERAL
SECTION 1402 – INSTALLATION <\/td>\n<\/tr>\n\n 126<\/td>\n SECTION 1403 – HEAT TRANSFER FLUIDS
SECTION 1404 – MATERIALS <\/td>\n<\/tr>\n\n 127<\/td>\n CHAPTER 15 – REFERENCED STANDARDS
ACCA
AHRI
ANSI
ASHRAE <\/td>\n<\/tr>\n\n 128<\/td>\n ASME
ASSE
ASTM <\/td>\n<\/tr>\n\n 130<\/td>\n AWS
AWWA
CSA
DOL
FS <\/td>\n<\/tr>\n\n 131<\/td>\n ICC
IIAR
MSS
NAIMA
NFPA <\/td>\n<\/tr>\n\n 132<\/td>\n SMACNA
UL <\/td>\n<\/tr>\n\n 135<\/td>\n CHAPTER 16 – AUTOMATIC SPRINKLER SYSTEMS; FIRE SUPPRESSION SYSTEMS
SECTION 1600 – AUTOMATIC SPRINKLER SYSTEMS; FIRE SUPPRESSION SYSTEMS <\/td>\n<\/tr>\n\n 137<\/td>\n APPENDIX A – COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 – ALL AIR FROM INSIDE THE BUILDING
FIGURE A-2 – ALL AIR FROM OUTDOORS\u2014INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC <\/td>\n<\/tr>\n\n 138<\/td>\n FIGURE A-3 – ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE A-4 – ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS <\/td>\n<\/tr>\n\n 139<\/td>\n FIGURE A-5 – CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n \n 140<\/td>\n FIGURE A-5\u2014continued CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n \n 141<\/td>\n INDEX <\/td>\n<\/tr>\n \n 146<\/td>\n MEMBERSHIP BENEFITS <\/td>\n<\/tr>\n \n 147<\/td>\n ICC ES PMG
HELPFUL LINKS: <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n MI<\/b><\/a><\/td>\n 2009<\/td>\n 147<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":26066,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2721],"product_tag":[],"class_list":{"0":"post-26065","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-mi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/26065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/26066"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=26065"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=26065"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=26065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}