{"id":252451,"date":"2024-10-19T16:40:02","date_gmt":"2024-10-19T16:40:02","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61800-5-22017\/"},"modified":"2024-10-25T11:59:23","modified_gmt":"2024-10-25T11:59:23","slug":"bs-en-61800-5-22017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61800-5-22017\/","title":{"rendered":"BS EN 61800-5-2:2017"},"content":{"rendered":"
This part of IEC 61800<\/span> <\/span>, which is a product standard, specifies requirements and makes recommendations for the design and development, integration and validation of safety related power drive systems ( PDS(SR))<\/i> in terms of their functional safety considerations. It applies to adjustable speed electrical power drive systems covered by the other parts of the IEC 61800<\/span> series<\/span> of standards as referred in IEC 61800\u20112<\/span> <\/span>.<\/p>\n The term \u201cintegration\u201d refers to the PDS(SR)<\/i> itself, not to its incorporation into the safety-related application.<\/p>\n<\/div>\n Other parts of IEC 61800<\/span> <\/span> cover rating specifications, EMC, electrical safety, etc.<\/p>\n<\/div>\n This International Standard is applicable where functional safety of a PDS(SR)<\/i> is claimed and the PDS(SR)<\/i> is operating mainly in the high demand or continuous mode (see 3.15<\/span>)<\/p>\n While low demand mode operation is possible for a PDS(SR)<\/i>, this standard concentrates on high demand and continuous mode. Safety sub-function<\/i>s implemented for high demand or continuous mode can also be used in low demand mode. Requirements for low demand mode are given in IEC 61508<\/span> series<\/span>. Some guidance for the estimation of average probability of dangerous failure on demand (PFD avg<\/sub>) value is provided in Annex F<\/span>.<\/p>\n This part of IEC 61800<\/span> <\/span> sets out safety-related considerations of PDS(SR)<\/i>s in terms of the framework of IEC 61508<\/span> <\/span>, and introduces requirements for PDS(SR)<\/i>s as subsystem<\/i>s of a safety-related system. It is intended to facilitate the realisation of the electrical\/ electronic\/ programmable electronic (E\/E\/PE) parts of a PDS(SR)<\/i> in relation to the safety performance of safety sub-function<\/i>(s) of a PDS.<\/p>\n Manufacturers and suppliers of PDS(SR)<\/i>s by using the normative requirements of this part of IEC 61800<\/span> <\/span> will indicate to users (system integrator, original equipment manufacturer) the safety performance for their equipment. This will facilitate the incorporation of a PDS(SR)<\/i> into a safety-related control system using the principles of IEC 61508<\/span> <\/span>, and possibly its specific sector implementations (for example IEC 61511<\/span> <\/span>, IEC 61513<\/span> <\/span>, IEC 62061<\/span> <\/span> or ISO 13849<\/span> <\/span>).<\/p>\n By applying the requirements from this part of the IEC 61800<\/span> series<\/span>, the corresponding requirements of IEC 61508<\/span> <\/span> that are necessary for a PDS(SR)<\/i> are fulfilled.<\/p>\n This part of IEC 61800<\/span> <\/span> does not specify requirements for:<\/p>\n the hazard<\/i> and risk analysis of a particular application;<\/p>\n<\/li>\n the identification of safety sub-function<\/i>s for that application;<\/p>\n<\/li>\n the initial allocation of SIL<\/i>s to those safety sub-function<\/i>s;<\/p>\n<\/li>\n the driven equipment except for interface arrangements;<\/p>\n<\/li>\n secondary hazard<\/i>s (for example from failure in a production or manufacturing process);<\/p>\n<\/li>\n the electrical, thermal and energy safety considerations, which are covered in + IEC 61800\u20115\u20111<\/span> <\/span>;<\/p>\n<\/li>\n the PDS(SR)<\/i> manufacturing process;<\/p>\n<\/li>\n the validity of signals and commands to the PDS(SR)<\/i>.<\/p>\n<\/li>\n security aspects (e.g. cyber security or PDS(SR)<\/i> security of access)<\/p>\n<\/li>\n<\/ul>\n The functional safety requirements of a PDS(SR)<\/i> are dependent on the application, and can be considered as a part of the overall risk assessment of the installation<\/i>. Where the supplier of the PDS(SR)<\/i> is not responsible for the driven equipment, the installation<\/i> designer is responsible for the risk assessment, and for specifying the functional and safety integrity requirements of the PDS(SR)<\/i>.<\/p>\n<\/div>\n This part of IEC 61800<\/span> <\/span> only applies to PDS(SR)<\/i>s implementing safety sub-function<\/i>s with a SIL<\/i> not greater than SIL<\/i> 3.<\/p>\n Figure 1<\/span> shows the installation and the functional parts of a PDS(SR)<\/i> that are considered in this part of IEC 61800<\/span> <\/span> and shows a logical representation of a PDS(SR)<\/i> rather than its physical description.<\/p>\n [Image removed.]<\/i><\/p>\n Adjustable speed electrical power drive systems – Safety requirements. Functional<\/b><\/p>\n\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n National foreword <\/td>\n<\/tr>\n \n 9<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 13<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 15<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 16<\/td>\n 1 Scope <\/td>\n<\/tr>\n \n 17<\/td>\n 2 Normative references
Figures
Figure 1 \u2013 Installation and functional parts of a PDS(SR) <\/td>\n<\/tr>\n\n 19<\/td>\n 3 Terms and definitions
Tables
Table 1 \u2013 Alphabetical list of terms and definitions <\/td>\n<\/tr>\n\n 25<\/td>\n 4 Designated safety sub-functions
4.1 General <\/td>\n<\/tr>\n\n 26<\/td>\n 4.2 Safety sub-functions
4.2.1 General
Figure 2 \u2013 Safety function consisting of safety sub-functions <\/td>\n<\/tr>\n\n 27<\/td>\n 4.2.2 Limit values
4.2.3 Stopping functions <\/td>\n<\/tr>\n\n 28<\/td>\n 4.2.4 Monitoring functions <\/td>\n<\/tr>\n \n 30<\/td>\n 4.2.5 Output functions \u2013 Safe brake control (SBC)
5 Management of functional safety
5.1 Objective
5.2 Requirements for the management of functional safety
5.3 PDS(SR) development lifecycle <\/td>\n<\/tr>\n\n 31<\/td>\n 5.4 Planning of PDS(SR) functional safety management
Figure 3 \u2013 PDS(SR) development lifecycle <\/td>\n<\/tr>\n\n 33<\/td>\n 5.5 Safety requirements specification (SRS) for a PDS(SR)
5.5.1 General
5.5.2 Safety sub-functions requirements specification <\/td>\n<\/tr>\n\n 34<\/td>\n 5.5.3 Safety integrity requirements specification <\/td>\n<\/tr>\n \n 35<\/td>\n 5.6 PDS(SR) safety system architecture specification
5.6.1 General
5.6.2 Requirements for safety system architecture specification <\/td>\n<\/tr>\n\n 36<\/td>\n 6 Requirements for design and development of a PDS(SR)
6.1 General requirements
6.1.1 Change in operational status
6.1.2 Design standards
6.1.3 Realisation
6.1.4 Safety integrity and fault detection <\/td>\n<\/tr>\n\n 37<\/td>\n 6.1.5 Safety and non-safety sub-functions
6.1.6 SIL for multiple safety sub-functions within one PDS(SR)
Table 2 \u2013 Example for determining the SIL from hardware and software independence <\/td>\n<\/tr>\n\n 38<\/td>\n 6.1.7 Integrated circuits with on-chip redundancy
6.1.8 Software requirements
6.1.9 Design documentation
6.2 PDS(SR) design requirements
6.2.1 Basic and well-tried safety principles
6.2.2 Requirements for the estimation of the probability of dangerous random hardware failures per hour (PFH) <\/td>\n<\/tr>\n\n 39<\/td>\n Table 3 \u2013 Safety integrity levels: target failure measures for a PDS(SR) safety sub-function <\/td>\n<\/tr>\n \n 41<\/td>\n 6.2.3 Architectural constraints <\/td>\n<\/tr>\n \n 42<\/td>\n 6.2.4 Estimation of safe failure fraction (SFF)
Table 4 \u2013 Maximum allowable safety integrity level for a safety sub-function carried out by a type A safety-related subsystem
Table 5 \u2013 Maximum allowable safety integrity level for a safety sub-function carried out by a type B safety-related subsystem <\/td>\n<\/tr>\n\n 43<\/td>\n 6.2.5 Requirements for systematic safety integrity of a PDS(SR) and PDS(SR) subsystems <\/td>\n<\/tr>\n \n 46<\/td>\n 6.2.6 Design requirements for electromagnetic (EM) immunity of a PDS(SR)
6.2.7 Design requirements for thermal immunity of a PDS(SR)
6.2.8 Design requirements for mechanical immunity of a PDS(SR)
6.3 Behaviour on detection of fault
6.3.1 Fault detection
6.3.2 Fault tolerance greater than zero
6.3.3 Fault tolerance zero
6.4 Additional requirements for data communications <\/td>\n<\/tr>\n\n 47<\/td>\n 6.5 PDS(SR) integration and testing requirements
6.5.1 Hardware integration
6.5.2 Software integration
6.5.3 Modifications during integration
6.5.4 Applicable integration tests
6.5.5 Test documentation <\/td>\n<\/tr>\n\n 48<\/td>\n 7 Information for use
7.1 General
7.2 Information and instructions for safe application of a PDS(SR) <\/td>\n<\/tr>\n\n 49<\/td>\n 8 Verification and validation
8.1 General <\/td>\n<\/tr>\n\n 50<\/td>\n 8.4 Documentation
9 Test requirements
9.1 Planning of tests
9.2 Functional testing <\/td>\n<\/tr>\n\n 51<\/td>\n 9.3 Electromagnetic (EM) immunity testing
9.3.1 General
9.3.2 Intended EM environment
9.3.3 Performance criterion (fail safe state \u2013 FS)
9.4 Thermal immunity testing
9.4.1 General <\/td>\n<\/tr>\n\n 52<\/td>\n 9.4.2 Functional thermal test
9.4.3 Component thermal test
9.5 Mechanical immunity testing
9.5.1 General
9.5.2 Vibration test
9.5.3 Shock test
9.5.4 Performance criterion for mechanical immunity tests (fail safe state \u2013 FS)
9.6 Test documentation <\/td>\n<\/tr>\n\n 53<\/td>\n 10 Modification
10.1 Objective
10.2 Requirements
10.2.1 General
10.2.2 Modification request
10.2.3 Impact analysis
10.2.4 Authorization
10.2.5 Documentation <\/td>\n<\/tr>\n\n 54<\/td>\n Annexes
Annex A (informative) Sequential task table
Table A.1 \u2013 Design and development procedure for PDS(SR) <\/td>\n<\/tr>\n\n 58<\/td>\n Annex B (informative) Example for estimation of PFH
B.1 General
B.2 Example PDS(SR) structure
B.2.1 General
Figure B.1 \u2013 Example PDS(SR) <\/td>\n<\/tr>\n\n 59<\/td>\n B.2.2 Subsystem A\/B
B.2.3 Subsystem PS\/VM
Figure B.2 \u2013 Subsystems of the PDS(SR) <\/td>\n<\/tr>\n\n 60<\/td>\n B.3 Example PDS(SR) PFH value determination
B.3.1 Subsystem \u201cA\/B\u201d (main subsystem)
Figure B.3 \u2013 Function blocks of subsystem A\/B <\/td>\n<\/tr>\n\n 62<\/td>\n Table B.1 \u2013 Determination of DC factor of subsystem A\/B <\/td>\n<\/tr>\n \n 63<\/td>\n Figure B.4 \u2013 Reliability model (Markov) of subsystem A\/B <\/td>\n<\/tr>\n \n 65<\/td>\n B.3.2 Subsystem \u201cPS\/VM\u201d
Figure B.5 \u2013 Function blocks of subsystem PS\/VM
Table B.2 \u2013 PFH value calculation results for subsystem A\/B <\/td>\n<\/tr>\n\n 66<\/td>\n Table B.3 \u2013 Determination of DC factor of subsystem A\/B <\/td>\n<\/tr>\n \n 67<\/td>\n Figure B.6 \u2013 Reliability model (Markov) of subsystem PS\/VM <\/td>\n<\/tr>\n \n 68<\/td>\n B.3.3 PFH value of the safety sub-function STO of PDS(SR)
Table B.4 \u2013 PFH value calculation results for subsystem PS\/VM <\/td>\n<\/tr>\n\n 69<\/td>\n B.4 Reduction of DC and SFF depending on test interval <\/td>\n<\/tr>\n \n 70<\/td>\n Annex C (informative) Available failure rate databases
C.1 Databases
C.2 Helpful standards concerning component failure <\/td>\n<\/tr>\n\n 72<\/td>\n Annex D (informative) Fault lists and fault exclusions
D.1 General
D.2 Remarks applicable to fault exclusions
D.2.1 Validity of exclusions
D.2.2 Tin whisker growth
D.2.3 Short-circuits on PWB-mounted parts <\/td>\n<\/tr>\n\n 73<\/td>\n D.3 Fault models
D.3.1 Conductors\/cables
D.3.2 Printed wiring boards\/assemblies
D.3.3 Terminal block
Table D.1 \u2013 Printed wiring boards\/assemblies <\/td>\n<\/tr>\n\n 74<\/td>\n D.3.4 Multi-pin connector
D.3.5 Electromechanical devices
Table D.2 \u2013 Terminal block
Table D.3 \u2013 Multi-pin connector <\/td>\n<\/tr>\n\n 75<\/td>\n D.3.6 Transformers
D.3.7 Inductances
D.3.8 Resistors
D.3.9 Resistor Networks
D.3.10 Potentiometers
D.3.11 Capacitors
D.3.12 Discrete semiconductors
Table D.4 \u2013 Electromechanical devices (for example relay, contactor relays) <\/td>\n<\/tr>\n\n 76<\/td>\n D.3.13 Signal Isolation components
D.3.14 Non-programmable integrated circuits
D.3.15 Programmable and\/or complex integrated circuits
Table D.5 \u2013 Signal Isolation components
Table D.6 \u2013 Non-programmable integrated circuits <\/td>\n<\/tr>\n\n 77<\/td>\n D.3.16 Motion and position feedback sensors
Table D.7 \u2013 Programmable and\/or complex integrated circuits <\/td>\n<\/tr>\n\n 78<\/td>\n Table D.8 \u2013 Motion and position feedback sensors <\/td>\n<\/tr>\n \n 81<\/td>\n Annex E (normative) Electromagnetic (EM) immunity requirement for PDS(SR)
E.1 General
E.2 Immunity requirements \u2013 low frequency disturbances <\/td>\n<\/tr>\n\n 82<\/td>\n Table E.1 \u2013 Minimum immunity requirements for voltage deviations, dips and short interruptions <\/td>\n<\/tr>\n \n 83<\/td>\n Table E.2 \u2013 PDS(SR) minimum immunity requirements for voltage deviations, dips and short interruptions on main power ports with a rated voltage above 1 000 V <\/td>\n<\/tr>\n \n 84<\/td>\n E.3 Immunity requirements \u2013 high frequency disturbances
Table E.3 \u2013 Immunity requirements \u2013 high frequency disturbances <\/td>\n<\/tr>\n\n 86<\/td>\n Table E.4 \u2013 General frequency ranges for mobile transmitters and ISM for radiated tests <\/td>\n<\/tr>\n \n 87<\/td>\n Table E.5 \u2013 General frequency ranges for mobile transmitters and ISM for conducted tests <\/td>\n<\/tr>\n \n 88<\/td>\n Annex F (informative) Estimation of PFDavg value for low demand with given PFH value
F.1 General
F.2 Estimation of PFDavg value for low demand with given PFH value <\/td>\n<\/tr>\n\n 89<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2017<\/td>\n 92<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":252454,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[518,2641],"product_tag":[],"class_list":{"0":"post-252451","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-130-99","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/252451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/252454"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=252451"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=252451"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=252451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}