Railway applications. Current collection systems. Pantographs, testing methods for contact strips
Published By | Publication Date | Number of Pages |
BSI | 2018 | 42 |
This European Standard specifies testing methods to establish the basic characteristics of newly manufactured pantograph contact strips. Not all tests may be relevant to some designs of contact strips. This standard does not define tests for pure metallic contact strips.
This European Standard excludes wear tests, and tests using a particular pantograph. Additional supplementary tests, out of the scope of this standard, may be necessary to determine suitability for a particular application and are by prior agreement between customer and manufacturer.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
9 | 1 Scope 2 Normative references 3 Terms and definitions 3.1 General |
10 | 3.2 Contact strip material 3.3 Contact strip construction |
11 | 4 Symbols and abbreviations |
12 | 5 Requirements for data sheets 5.1 Data sheet and design drawing 5.2 Contact strip material 5.3 Contact strip characteristics |
13 | 6 Test categories and environmental conditions 6.1 General 6.2 Type tests 6.3 Routine tests 6.4 Environment 6.5 Ambient air temperature |
14 | 6.6 Test sequence |
18 | 7 Test procedures 7.1 Tests for the temperature characteristic of the contact strip under current loading 7.1.1 General 7.1.2 Test method – To determine the temperature characteristic of the contact strip under current loading |
19 | 7.2 Test for deflection and extension of the carbon contact strip under extremes of temperature 7.2.1 General 7.2.2 Test method – High temperature test 7.2.2.1 General 7.2.2.2 Test acceptance criteria |
20 | 7.2.3 Test method – Low temperature test 7.2.3.1 General 7.2.3.2 Test acceptance criteria 7.3 Test for flexural characteristic of the contact strip 7.3.1 General 7.3.2 Test method |
21 | 7.3.3 Test acceptance criteria 7.4 Test for shear strength of the contact strip 7.4.1 General 7.4.1.1 Introduction 7.4.1.2 Test acceptance criteria |
22 | 7.4.2 Test method – Test at ambient temperature 7.4.2.1 General 7.4.2.2 Test acceptance criteria |
24 | 7.4.3 Test method – Test at specified temperature 7.4.3.1 General 7.4.3.2 Test acceptance criteria 7.5 Test of auto-drop detection sensor integral with contact strips 7.5.1 General 7.5.2 Test method – Sealing integrity 7.5.2.1 General |
25 | 7.5.2.2 Test acceptance criteria 7.5.3 Test method – Sealing integrity temperature test 7.5.3.1 Test method – Sealing integrity at Tcs. 7.5.3.2 Test method – Sealing integrity at low temperature |
26 | 7.5.4 Test method – Air flow continuity 7.5.4.1 General 7.5.4.2 Test acceptance criteria 7.5.5 Test method – Impact function of the auto-drop detection sensor 7.5.5.1 General |
27 | 7.5.5.2 Test acceptance criteria |
28 | 7.6 Test of mechanical fatigue resistance of the contact strip 7.6.1 General 7.6.2 Test method 7.6.2.1 General |
29 | 7.6.2.2 Test acceptance criteria 7.7 Test of the electrical resistance of the contact strip 7.7.1 General 7.7.2 Test method 7.7.2.1 General 7.7.2.2 Test acceptance criteria – Type test and Routine test |
30 | 7.8 Test of the metal content for metal impregnated (metalized) contact strips 7.8.1 General 7.8.2 Method 1: Weighing a part before and after the impregnation 7.8.2.1 General 7.8.2.2 Test acceptance criteria |
31 | 7.8.3 Method 2: Determination of the apparent density of the material before and after the impregnation 7.8.3.1 General 7.8.3.2 Test acceptance criteria 7.9 Test of the coefficient of friction 7.9.1 General 7.9.2 Test method 7.9.2.1 General |
32 | 7.9.2.2 Test acceptance criteria – Type test 7.10 Optional test of the impact resistance of the Carbon material 7.10.1 General 7.10.2 Test method 7.10.2.1 General 7.10.2.2 Test acceptance criteria – Type test 7.11 Test of the thermal fatigue properties of the contact strip 7.11.1 General 7.11.2 Test method – Thermal fatigue test 7.11.2.1 General 7.11.2.2 Test acceptance criteria |
34 | Annex A (informative)Parameters to be specified by the customer and graphical representation of customer specified values for pantograph automatic dropping device operation A.1 Parameters to be specified by the customer |
35 | A.2 Graphical representation of customer specified values for pantograph automatic dropping device operation |
36 | Annex B (normative)Current loading test apparatus B.1 Current loading test apparatus – copper test electrode |
37 | B.2 Current loading test apparatus |