ASTM-E779 2010
$44.96
E779-10 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
Published By | Publication Date | Number of Pages |
ASTM | 2010 | 10 |
1.1 This test method measures air-leakage rates through a building envelope under controlled pressurization and de-pressurization.
1.2 This test method is applicable to small temperature differentials and low-wind pressure differential, therefore strong winds and large indoor-outdoor temperature differentials shall be avoided.
1.3 This test method is intended to quantify the air tightness of a building envelope. This test method does not measure air change rate or air leakage rate under normal weather conditions and building operation.
Note 1See Test Method E741 to directly measure air-change rates using the tracer gas dilution method
1.4 This test method is intended to be used for measuring the air tightness of building envelopes of single-zone buildings. For the purpose of this test method, many multi-zone buildings can be treated as single-zone buildings by opening interior doors or by inducing equal pressures in adjacent zones.
1.5 Only metric SI units of measurement are used in this standard. If a value for measurement is followed by a value in other units in parentheses, the second value may be approximate. The first stated value is the requirement.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 7.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Summary of Test Method Significance and Use Apparatus Hazards Procedure TABLE 1 |
3 | Data Analysis and Calculations FIG. 1 |
4 | Report FIG. 2 |
5 | Precision and Bias Keywords A1. PROCEDURE FOR ESTIMATING PRECISION ERRORS IN DERIVED QUANTITIES A1.1 |
6 | X1. DEPENDENCE OF AIR DENSITY AND VISCOSITY ON TEMPERATURE AND BAROMETRIC PRESSURE (ELEVATION) X1.1 TABLE A1.1 |
7 | X2. EXAMPLE CALCULATIONS X2.1 Introduction X2.2 Site Data X2.3 Checking Test Limits X2.4 Pressurization Data TABLE X2.1 TABLE X2.2 |
8 | X2.5 Depressurization Data TABLE X2.3 TABLE X2.4 |
9 | X2.6 Combined Pressurization and Depressurization Data X2.7 Estimates of Confidence Limits TABLE X2.5 TABLE X2.6 |