{"id":436657,"date":"2024-10-20T07:55:33","date_gmt":"2024-10-20T07:55:33","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-17-2022\/"},"modified":"2024-10-26T14:56:49","modified_gmt":"2024-10-26T14:56:49","slug":"ieee-c37-17-2022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-17-2022\/","title":{"rendered":"IEEE C37.17-2022"},"content":{"rendered":"
Revision Standard – Active. This standard pertains to the requirements for current and voltage protective functions of 1) direct-acting overcurrent electromechanical trip devices, 2) direct-acting overcurrent electronic trip systems, 3) reverse-current trip systems, and 4) undervoltage trip devices that are integral with low-voltage ac (1000 V and below) and general-purpose low-voltage dc (1500 V and below) power circuit breakers covered by IEEE Std C37.13 and IEEE Std C37.14. Additional information, communication, and\/or additional internal or external protective functions or devices are not covered by this standard. This standard should not be interpreted to restrict the inclusion of such functionality in the device.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C37.17\u2122-2022 Front cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 1.\u2002Overview 1.1\u2002Scope 1.2\u2002Word usage <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 2.\u2002Normative references 3.\u2002Definitions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.\u2002Preferred trip device current ratings or settings (amperes) 5.\u2002Trip system self-monitoring 5.1\u2002General <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.2\u2002Trip system health indication 5.3\u2002Trip actuator circuit integrity 5.4\u2002Current sensing circuit integrity 6.\u2002Types and response of direct-acting overcurrent trip functions 6.1\u2002General 6.2\u2002Long-time delay 6.3\u2002Short-time delay 6.4\u2002Instantaneous <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.5\u2002Neutral overload 6.6\u2002Ground fault 6.7\u2002Functions modifying the response of direct-acting overcurrent trip functions <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.\u2002Requirements for direct-acting overcurrent trip functions 7.1\u2002General 7.2\u2002Long-time delay trip functions (electromechanical devices only) 7.3\u2002Long-time delay trip functions (electronic devices only) 7.4\u2002Short-time delay trip functions 7.5\u2002Instantaneous trip functions (low range electromechanical devices only) <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7.6\u2002Instantaneous trip functions (electronic devices only) 7.7\u2002Neutral overload functions 7.8\u2002Ground fault trip functions 8.\u2002Delay times of direct-acting overcurrent trip functions 8.1\u2002Long-time-delay trip functions 8.2\u2002Short-time-delay trip functions 8.3\u2002Short-time-delay ground fault trip function 9.\u2002Reverse-current trip devices for general purpose dc circuit breakers 10.\u2002Undervoltage trip devices 10.1\u2002General <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 10.2\u2002Drop-out voltage range 10.3\u2002Pickup or seal-in voltage 10.4\u2002Maximum operating voltage 11.\u2002Tests 11.1\u2002General 12.\u2002Software process verification <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex A (informative) Time-overcurrent characteristics A.1\u2002Sample phase time-overcurrent characteristics and tolerance bands <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | A.2\u2002Sample ground time-overcurrent characteristics and tolerance bands <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | A.3\u2002Diagram clarifying Table 3 <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex B (informative) Arc flash mitigation or energy reduction integral to the trip system <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex C (informative) Use of trip systems not originally supplied\/offered\/qualified with the breaker by the original circuit breaker manufacturer <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex D (informative) Definitions preserved for historical continuity <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex E (informative) Bibliography <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Back cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers (Approved Draft)<\/b><\/p>\n |