{"id":380314,"date":"2024-10-20T03:06:18","date_gmt":"2024-10-20T03:06:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61784-3-82021\/"},"modified":"2024-10-26T05:37:32","modified_gmt":"2024-10-26T05:37:32","slug":"bs-en-iec-61784-3-82021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61784-3-82021\/","title":{"rendered":"BS EN IEC 61784-3-8:2021"},"content":{"rendered":"
This part of IEC 61784-3 (all parts) specifies a safety communication layer (services and protocol) based on CPF 8 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 18 and Type 23. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only.<\/p>\n
\nNOTE 1 It does not cover electrical safety and intrinsic safety aspects. Electrical safety relates to hazards such as electrical shock. Intrinsic safety relates to hazards associated with potentially explosive atmospheres.<\/p>\n<\/blockquote>\n
This document defines mechanisms for the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 (all parts)1 for functional safety. These mechanisms may be used in various industrial applications such as process control, manufacturing automation and machinery.<\/p>\n
This document provides guidelines for both developers and assessors of compliant devices and systems.<\/p>\n
\nNOTE 2 The resulting SIL claim of a system depends on the implementation of the selected functional safety communication profile within this system \u2013 implementation of a functional safety communication profile according to this document in a standard device is not sufficient to qualify it as a safety device.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 5<\/td>\n Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n \n 7<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 12<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 14<\/td>\n 0 Introduction
0.1 General
Figure 1 \u2013 Relationships of IEC 617843 with other standards (machinery) <\/td>\n<\/tr>\n\n 15<\/td>\n Figures
Figure 2 \u2013 Relationships of IEC 617843 with other standards (process) <\/td>\n<\/tr>\n\n 16<\/td>\n 0.2 Patent declaration <\/td>\n<\/tr>\n \n 17<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 18<\/td>\n 3 Terms, definitions, symbols, abbreviated terms and conventions
3.1 Terms and definitions <\/td>\n<\/tr>\n\n 19<\/td>\n 3.1.1 Common terms and definitions <\/td>\n<\/tr>\n \n 25<\/td>\n 3.1.2 CPF 8: Additional terms and definitions <\/td>\n<\/tr>\n \n 26<\/td>\n 3.2 Symbols and abbreviated terms
3.2.1 Common symbols and abbreviated terms <\/td>\n<\/tr>\n\n 27<\/td>\n 3.2.2 CPF 8: Additional symbols and abbreviated terms
3.3 Conventions
4 Overview
5 General
6 Safety communication layer services <\/td>\n<\/tr>\n\n 28<\/td>\n 7 Safety communication layer protocol
8 Safety communication layer management
9 System requirements
10 Assessment
11 FSCP 8\/1
11.1 Scope \u2013 FSCP 8\/1
11.2 Normative references \u2013 FSCP 8\/1
11.3 Terms, definitions, symbols, abbreviated terms and conventions \u2013 FSCP 8\/1
11.4 Overview of FSCP 8\/1 (CC-Link Safety\u2122) <\/td>\n<\/tr>\n\n 29<\/td>\n 11.5 General \u2013 FSCP 8\/1
11.5.1 External documents providing specifications for the profile
11.5.2 Safety functional requirements
11.5.3 Safety measures <\/td>\n<\/tr>\n\n 30<\/td>\n Tables
Table 1 \u2013 Selection of the various measures for possible errors <\/td>\n<\/tr>\n\n 31<\/td>\n 11.5.4 Safety communication layer structure <\/td>\n<\/tr>\n \n 32<\/td>\n 11.5.5 Relationships with FAL (and DLL, PhL)
11.6 Safety communication layer services for FSCP 8\/1
11.6.1 General
11.6.2 SASEs
Figure 3 \u2013 Relationship between SCL and the other layers of IEC 61158 Type 18 <\/td>\n<\/tr>\n\n 33<\/td>\n 11.6.3 SARs <\/td>\n<\/tr>\n \n 34<\/td>\n 11.6.4 Process data SAR ASEs <\/td>\n<\/tr>\n \n 35<\/td>\n 11.7 Safety communication layer protocol for FSCP 8\/1
11.7.1 Safety PDU format <\/td>\n<\/tr>\n\n 36<\/td>\n Table 2 \u2013 M1 safety device manager attribute format
Table 3 \u2013 S1 safety device manager attribute format
Table 4 \u2013 M1 safety connection manager attribute format
Table 5 \u2013 S1 safety connection manager attribute format <\/td>\n<\/tr>\n\n 37<\/td>\n Table 6 \u2013 M1 safety cyclic transmission attribute format <\/td>\n<\/tr>\n \n 38<\/td>\n Table 7 \u2013 S1 safety cyclic transmission attribute format
Table 8 \u2013 M1 safety device manager attribute encoding <\/td>\n<\/tr>\n\n 39<\/td>\n Table 9 \u2013 S1 safety device manager attribute encoding
Table 10 \u2013 M1 safety connection manager attribute encoding
Table 11 \u2013 S1 safety connection manager attribute encoding <\/td>\n<\/tr>\n\n 40<\/td>\n Table 12 \u2013 M1 safety cyclic transmission attribute encoding <\/td>\n<\/tr>\n \n 42<\/td>\n Table 13 \u2013 S1 safety cyclic transmission attribute encoding <\/td>\n<\/tr>\n \n 43<\/td>\n 11.7.2 State description <\/td>\n<\/tr>\n \n 44<\/td>\n Figure 4 \u2013 State diagram <\/td>\n<\/tr>\n \n 46<\/td>\n Table 14 \u2013 Safety master monitor timer operation
Table 15 \u2013 Safety slave monitor timer operation
Table 16 \u2013 Safety data monitor timer operation <\/td>\n<\/tr>\n\n 48<\/td>\n 11.8 Safety communication layer management for FSCP 8\/1
11.8.1 General
11.8.2 Connection establishment and confirmation processing
11.8.3 Safety slave verification
Table 17 \u2013 Details of connection establishment and confirmation processing
Table 18 \u2013 Details of slave information verification processing <\/td>\n<\/tr>\n\n 49<\/td>\n 11.9 System requirements for FSCP 8\/1
11.9.1 Indicators and switches
Table 19 \u2013 Details of safety slave parameter transmission processing <\/td>\n<\/tr>\n\n 50<\/td>\n 11.9.2 Installation guidelines
11.9.3 Safety function response time
Table 20 \u2013 Monitor LEDs <\/td>\n<\/tr>\n\n 51<\/td>\n Table 21 \u2013 Safety function response time calculation
Table 22 \u2013 Safety function response time definition of terms <\/td>\n<\/tr>\n\n 52<\/td>\n 11.9.4 Duration of demands
11.9.5 Constraints for calculation of system characteristics
11.9.6 Maintenance
11.9.7 Safety manual
11.10 Assessment for FSCP 8\/1 <\/td>\n<\/tr>\n\n 53<\/td>\n 12 FSCP 8\/2
12.1 Scope \u2013 FSCP 8\/2
12.2 Normative references \u2013 FSCP 8\/2
12.3 Terms, definitions, symbols, abbreviated terms and conventions \u2013 FSCP 8\/2
12.4 Overview of FSCP 8\/2 (CC-Link IE\u2122 Safety communication function)
12.5 General \u2013 FSCP 8\/2
12.5.1 External documents providing specifications for the profile <\/td>\n<\/tr>\n\n 54<\/td>\n 12.5.2 Safety functional requirements
12.5.3 Safety measures <\/td>\n<\/tr>\n\n 55<\/td>\n Table 23 \u2013 Selection of the various measures for possible errors <\/td>\n<\/tr>\n \n 56<\/td>\n Figure 5 \u2013 Detection of unintended repetition
Figure 6 \u2013 Detection of incorrect sequence <\/td>\n<\/tr>\n\n 57<\/td>\n Figure 7 \u2013 Detection of loss <\/td>\n<\/tr>\n \n 58<\/td>\n Figure 8 \u2013 Detection of unacceptable delay by time stamps
Figure 9 \u2013 Detection of unacceptable delay by timer <\/td>\n<\/tr>\n\n 59<\/td>\n 12.5.4 Safety communication layer structure
Figure 10 \u2013 Protocol Hierarchy <\/td>\n<\/tr>\n\n 60<\/td>\n 12.5.5 Relationships with FAL (and DLL, PhL)
12.6 Safety communication layer services for FSCP 8\/2
12.6.1 General
12.6.2 Connection reestablishment services
Table 24 \u2013 SSStart
Table 25 \u2013 SSRestart <\/td>\n<\/tr>\n\n 61<\/td>\n 12.6.3 Data transmission services
Table 26 \u2013 SSInvokeFunc
Table 27 \u2013 SSRead <\/td>\n<\/tr>\n\n 62<\/td>\n 12.6.4 Connection termination notification services
12.7 Safety communication layer protocol for FSCP 8\/2
12.7.1 Safety PDU format
Table 28 \u2013 SS-Write
Table 29 \u2013 SSTerminate <\/td>\n<\/tr>\n\n 63<\/td>\n Figure 11 \u2013 Safety PDU Structure
Table 30 \u2013 Safety PDU elements <\/td>\n<\/tr>\n\n 64<\/td>\n Figure 12 \u2013 CTRL Configuration
Table 31 \u2013 CTRL Elements <\/td>\n<\/tr>\n\n 67<\/td>\n Figure 13 \u2013 SASEM and SASES TS
Figure 14 \u2013 SData during safety refresh <\/td>\n<\/tr>\n\n 68<\/td>\n Figure 15 \u2013 SData not during safety refresh
Figure 16 \u2013 SData header configuration <\/td>\n<\/tr>\n\n 69<\/td>\n 12.7.2 Safety FAL service protocol machine (SFSPM)
Figure 17 \u2013 CRC calculation
Figure 18 \u2013 Communication models <\/td>\n<\/tr>\n\n 70<\/td>\n Figure 19 \u2013 SFSPM state transition diagram
Table 32 \u2013 State list <\/td>\n<\/tr>\n\n 72<\/td>\n Figure 20 \u2013 Connection establishment sequence <\/td>\n<\/tr>\n \n 73<\/td>\n Figure 21 \u2013 Optional sequence during connection establishment sequence
Figure 22 \u2013 Communication sequence during safety refresh communication <\/td>\n<\/tr>\n\n 74<\/td>\n Figure 23 \u2013 Offset measurement and generation sequence during safety refresh communication <\/td>\n<\/tr>\n \n 75<\/td>\n Figure 24 \u2013 SFSPMM state transition diagram
Table 33 \u2013 SFSPMM timers <\/td>\n<\/tr>\n\n 76<\/td>\n Table 34 \u2013 SFSPMM state transition table <\/td>\n<\/tr>\n \n 79<\/td>\n Figure 25 \u2013 Sequence other than during safety refresh
Figure 26 \u2013 SConnectreq
Table 35 \u2013 support_functions <\/td>\n<\/tr>\n\n 80<\/td>\n Figure 27 \u2013 SInitConfirmNetPrmreq
Figure 28 \u2013 net_prm_list
Figure 29 \u2013 SInitVerifyStnPrmreq <\/td>\n<\/tr>\n\n 81<\/td>\n Figure 30 \u2013 stn_prm_list
Figure 31 \u2013 SInvokeFuncreq <\/td>\n<\/tr>\n\n 82<\/td>\n Figure 32 \u2013 SWriteErrorInforeq
Table 36 \u2013 error_category
Table 37 \u2013 error_category for AL errors <\/td>\n<\/tr>\n\n 83<\/td>\n Figure 33 \u2013 date_and_time_of_occurence
Table 38 \u2013 error_code <\/td>\n<\/tr>\n\n 84<\/td>\n Figure 34 \u2013 SFSPMS state transition diagram
Table 39 \u2013 SFSPMS timers <\/td>\n<\/tr>\n\n 85<\/td>\n Table 40 \u2013 SFSPMS state transition table <\/td>\n<\/tr>\n \n 89<\/td>\n Figure 35 \u2013 Sequence other than during safety refresh
Figure 36 \u2013 SConnectrsp <\/td>\n<\/tr>\n\n 90<\/td>\n Figure 37 \u2013 SInitConfirmNetPrmrsp
Figure 38 \u2013 SInitVerifyStnPrmrsp <\/td>\n<\/tr>\n\n 91<\/td>\n Figure 39 \u2013 SInvokeFuncrsp <\/td>\n<\/tr>\n \n 92<\/td>\n Figure 40 \u2013 Offset calculation procedure of safety clock <\/td>\n<\/tr>\n \n 95<\/td>\n 12.8 Safety communication layer management for FSCP 8\/2
12.8.1 Parameter Definitions
Table 41 \u2013 Parameters used by safety communication layer <\/td>\n<\/tr>\n\n 96<\/td>\n Figure 41 \u2013 Relationship between transmissioninterval fluctuation and transmission_interval <\/td>\n<\/tr>\n \n 98<\/td>\n Figure 42 \u2013 Calculation of allowable_refresh_interval <\/td>\n<\/tr>\n \n 99<\/td>\n 12.8.2 Parameter Setup
Figure 43 \u2013 Calculation of allowable_delay <\/td>\n<\/tr>\n\n 100<\/td>\n 12.8.3 Management Services
Table 42 \u2013 SMSetSafetyStationInfo
Table 43 \u2013 Safety station information setting parameters of SMSetSafetyStationInfo <\/td>\n<\/tr>\n\n 101<\/td>\n Table 44 \u2013 SMSetSafetyNetworkParameter
Table 45 \u2013 Safety network parameters of SMSetSafetyNetworkParameter
Table 46 \u2013 SMGetSafetyStationInfo <\/td>\n<\/tr>\n\n 102<\/td>\n Table 47 \u2013 Safety station information parameters of SMGetSafetyStationInfo (Request)
Table 48 \u2013 Safety station information parameters of SMGetSafetyStationInfo (Response)
Table 49 \u2013 SMGetSafetyNetworkParameter
Table 50 \u2013 Parameters of SMGetSafetyNetworkParameter request <\/td>\n<\/tr>\n\n 103<\/td>\n 12.9 System requirements for FSCP 8\/2
12.9.1 Indicators and switches
Table 51 \u2013 Parameters of SMGetSafetyNetworkParameter response <\/td>\n<\/tr>\n\n 104<\/td>\n Table 52 \u2013 Monitor LEDs
Table 53 \u2013 Communication port monitor LEDs <\/td>\n<\/tr>\n\n 105<\/td>\n 12.9.2 Installation guidelines
12.9.3 Safety function response time
Figure 44 \u2013 Calculation of response time between safety PLCs <\/td>\n<\/tr>\n\n 106<\/td>\n 12.9.4 Duration of demands
12.9.5 Constraints for calculation of system characteristics <\/td>\n<\/tr>\n\n 107<\/td>\n 12.9.6 Maintenance
12.9.7 Safety manual
Figure 45 \u2013 Constraints on NSE and m <\/td>\n<\/tr>\n\n 108<\/td>\n 12.10 Assessment for FSCP 8\/2 <\/td>\n<\/tr>\n \n 109<\/td>\n Annex A (informative) Additional information for functional safety communication profiles of CPF 8
Table A.1 \u2013 Residual error probability for FSCP 8\/1 CRC <\/td>\n<\/tr>\n\n 110<\/td>\n Figure A.1 \u2013 Allowable_delay and offset calculation deviation
Table A.2 \u2013 Residual error probability for FSCP 8\/2 CRC <\/td>\n<\/tr>\n\n 112<\/td>\n Annex B (informative) Information for assessment of the functional safety communication profiles of CPF 8 <\/td>\n<\/tr>\n \n 113<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Industrial communication networks. Profiles – Functional safety fieldbuses. Additional specifications for CPF8<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2021<\/td>\n 116<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":380319,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[385,2641],"product_tag":[],"class_list":{"0":"post-380314","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-25-040-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/380314","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/380319"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=380314"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=380314"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=380314"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}