{"id":254709,"date":"2024-10-19T16:49:55","date_gmt":"2024-10-19T16:49:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61850-7-22010\/"},"modified":"2024-10-25T12:15:41","modified_gmt":"2024-10-25T12:15:41","slug":"bs-en-61850-7-22010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61850-7-22010\/","title":{"rendered":"BS EN 61850-7-2:2010"},"content":{"rendered":"

IEC 61850-7-2:2010 applies to the ACSI communication for utility automation. The ACSI provides the following abstract communication service interfaces: – abstract interface describing communications between a client and a remote server; – and abstract interface for fast and reliable system-wide event distribution between an application in one device and many remote applications in different devices (publisher\/sub-scriber) and for transmission of sampled measured values (publisher\/subscriber). Major technical changes with regard to the previous edition are as follows: – data types not required have been removed, – service tracking for control blocks have been added, – security issues are solved by the IEC 62351 series, – service tracking for control blocks have been added, – the view concept will be according to the new work on role bases access (RBA), – security issues are solved by the IEC 62351 series. This publication is of core relevance for Smart Grid.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
8<\/td>\nCONTENTS <\/td>\n<\/tr>\n
15<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
16<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
17<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
18<\/td>\n4 Abbreviated terms <\/td>\n<\/tr>\n
19<\/td>\n5 ACSI overview and basic concepts
5.1 Conceptual model of IEC\u00a061850 <\/td>\n<\/tr>\n
20<\/td>\n5.2 The meta-meta model
5.3 The meta model
Figures
Figure\u00a01 \u2013 Excerpt of conceptual model of IEC\u00a061850 <\/td>\n<\/tr>\n
21<\/td>\nFigure 2 \u2013 Basic conceptual class model of the ACSI <\/td>\n<\/tr>\n
23<\/td>\nFigure 3 \u2013 Conceptual service model of the ACSI <\/td>\n<\/tr>\n
24<\/td>\nTables
Table 1 \u2013 ACSI model classes with related services <\/td>\n<\/tr>\n
25<\/td>\n5.4 The domain type model
5.5 The data instance model
Figure 4 \u2013 Core of the conceptual meta model and relationship <\/td>\n<\/tr>\n
26<\/td>\n6 TypeDefinitions
6.1 General
Figure 5 \u2013 Data instance model (conceptual) <\/td>\n<\/tr>\n
27<\/td>\nTable 2 \u2013 BasicTypes <\/td>\n<\/tr>\n
28<\/td>\nTable 3 \u2013 ObjectName type
Table 4 \u2013 ObjectReference type <\/td>\n<\/tr>\n
29<\/td>\nTable 5 \u2013 ServiceError type <\/td>\n<\/tr>\n
30<\/td>\nTable 6 \u2013 PACKED-LIST type
Table 7 \u2013 TimeStamp type <\/td>\n<\/tr>\n
31<\/td>\nTable 8 \u2013 TimeQuality definition <\/td>\n<\/tr>\n
32<\/td>\nTable 9 \u2013 TimeAccuracy
Table 10 \u2013 TriggerConditions type <\/td>\n<\/tr>\n
33<\/td>\n7 GenServerClass model
7.1 GenServerClass definition
Table 11 \u2013 ReasonForInclusion
Table 12 \u2013 GenServerClass definition <\/td>\n<\/tr>\n
34<\/td>\n7.2 Server class services
Figure 6 \u2013 Overview about GetDirectory and GetDefinition services <\/td>\n<\/tr>\n
36<\/td>\n8 Application association model
8.1 Introduction
8.2 Concept of application associations
8.3 TWO-PARTY-APPLICATION-ASSOCIATION (TPAA) class model <\/td>\n<\/tr>\n
37<\/td>\nFigure 7 \u2013 Normal operation
Figure 8 \u2013 Aborting association
Table 13 \u2013 TWO-PARTY-APPLICATION-ASSOCIATION (TPAA) class definition <\/td>\n<\/tr>\n
41<\/td>\n8.4 MULTICAST-APPLICATION-ASSOCIATION (MCAA) class
Figure 9 \u2013 Principle of multicast application association
Table 14 \u2013 MULTICAST-APPLICATION-ASSOCIATION (MCAA) class definition <\/td>\n<\/tr>\n
42<\/td>\n9 GenLogicalDeviceClass model
9.1 GenLogicalDeviceClass definition
9.2 GenLogicalDeviceClass services
Table 15 \u2013 GenLogicalDeviceClass (GenLD) class definition <\/td>\n<\/tr>\n
43<\/td>\n10 GenLogicalNodeClass model
10.1 GenLogicalNodeClass definition <\/td>\n<\/tr>\n
44<\/td>\nFigure 10 \u2013 Basic conceptual model of the GenLogicalNodeClass
Table 16 \u2013 GenLogicalNodeClass definition <\/td>\n<\/tr>\n
46<\/td>\n10.2 GenLogicalNodeClass services <\/td>\n<\/tr>\n
49<\/td>\n11 Generic data object class model
11.1 GenDataObjectClass diagram
11.2 GenDataObjectClass syntax
Figure 11 \u2013 Basic conceptual class model of the GenDataObjectClass <\/td>\n<\/tr>\n
50<\/td>\n11.3 GenDataObjectClass attributes
11.4 GenDataObjectClass services
Table 17 \u2013 GenDataObjectClass definition <\/td>\n<\/tr>\n
51<\/td>\nFigure 12 \u2013 Excerpt of GenDataObjectClass services <\/td>\n<\/tr>\n
54<\/td>\n12 Generic common data class model
12.1 General <\/td>\n<\/tr>\n
55<\/td>\n12.2 GenCommonDataClass
Figure 13 \u2013 Class diagram of the GenCommonDataClass
Figure 14 \u2013 Conceptual Class diagram of the GenCommonDataClass <\/td>\n<\/tr>\n
56<\/td>\n12.3 GenDataAttributeClass
Figure 15 \u2013 Class diagram of the GenDataAttributeClass
Table 18 \u2013 GenCommonDataClass definition <\/td>\n<\/tr>\n
57<\/td>\nTable 19 \u2013 GenDataAttributeClass definition <\/td>\n<\/tr>\n
58<\/td>\nTable 20 \u2013 Functional constraint values <\/td>\n<\/tr>\n
60<\/td>\nFigure\u00a016 \u2013 Relation of TrgOp and Reporting
Table\u00a021 \u2013 TrgOp <\/td>\n<\/tr>\n
61<\/td>\n12.4 GenConstructedAttributeClass
12.5 GenSubDataAttributeClass
Figure 17 \u2013 Class diagram of the GenConstructedAttributeClass
Table 22 \u2013 GenConstructedAttributeClass definition <\/td>\n<\/tr>\n
62<\/td>\n12.6 Referencing data objects and their components
Table 23 \u2013 GenSubDataAttributeClass definition <\/td>\n<\/tr>\n
64<\/td>\nFigure 18 \u2013 Relation of types (example) <\/td>\n<\/tr>\n
65<\/td>\n13 DATA-SET class model
13.1 General
Figure 19 \u2013 Example of a data object <\/td>\n<\/tr>\n
66<\/td>\n13.2 DATA-SET class definition
Figure 20 \u2013 Dynamic creation of data set instances <\/td>\n<\/tr>\n
67<\/td>\n13.3 DATA-SET class services
Table 24 \u2013 DATA-SET (DS) class definition <\/td>\n<\/tr>\n
72<\/td>\n14 Service tracking
14.1 General
14.2 Common service tracking (CST) <\/td>\n<\/tr>\n
73<\/td>\nTable 25 \u2013 Common service tracking common data class (CST) definition <\/td>\n<\/tr>\n
74<\/td>\n15 Modelling of control block classes
15.1 General
15.2 Control block class models
Table 26 \u2013 ServiceType type <\/td>\n<\/tr>\n
75<\/td>\n15.3 Control block tracking services
Table 27 \u2013 CB class definition <\/td>\n<\/tr>\n
76<\/td>\nFigure 21 \u2013 Control block service mapping <\/td>\n<\/tr>\n
77<\/td>\nTable 28 \u2013 Buffered report tracking service (BTS) definition <\/td>\n<\/tr>\n
78<\/td>\nTable 29 \u2013 Unbuffered report tracking service (UTS) definition <\/td>\n<\/tr>\n
80<\/td>\nTable 30 \u2013 Log control block tracking service (LTS) definition <\/td>\n<\/tr>\n
81<\/td>\nTable 31 \u2013 Log tracking service (OTS) definition <\/td>\n<\/tr>\n
82<\/td>\nTable 32 \u2013 GOOSE Control block tracking service (GTS) definition <\/td>\n<\/tr>\n
83<\/td>\nTable 33 \u2013 MSVCB tracking service (MTS) definition <\/td>\n<\/tr>\n
84<\/td>\nTable 34 \u2013 USVCB tracking service (NTS) definition <\/td>\n<\/tr>\n
85<\/td>\nTable 35 \u2013 SGCB tracking service (STS) definition <\/td>\n<\/tr>\n
86<\/td>\n16 SETTING-GROUP-CONTROL-BLOCK class model
16.1 General <\/td>\n<\/tr>\n
87<\/td>\n16.2 SGCB class definition
Figure 22 \u2013 Basic model of the settings model <\/td>\n<\/tr>\n
88<\/td>\nTable 36 \u2013 SGCB class definition <\/td>\n<\/tr>\n
89<\/td>\n16.3 SGCB class services <\/td>\n<\/tr>\n
95<\/td>\n17 REPORT-CONTROL-BLOCK and LOG-CONTROL-BLOCK class models
17.1 Overview <\/td>\n<\/tr>\n
96<\/td>\nFigure 23 \u2013 Basic building blocks for reporting and logging <\/td>\n<\/tr>\n
97<\/td>\n17.2 REPORT-CONTROL-BLOCK class model <\/td>\n<\/tr>\n
98<\/td>\nTable 37 \u2013 BRCB class definition <\/td>\n<\/tr>\n
99<\/td>\nFigure 24 \u2013 BRCB state machine <\/td>\n<\/tr>\n
100<\/td>\nFigure 25 \u2013 General queue of entries for report handler <\/td>\n<\/tr>\n
102<\/td>\nFigure 26 \u2013 Buffer time <\/td>\n<\/tr>\n
103<\/td>\nFigure 27 \u2013 State Machine for Sequence Number Generation <\/td>\n<\/tr>\n
105<\/td>\nFigure 28 \u2013 Logical state machine for general interrogation <\/td>\n<\/tr>\n
108<\/td>\nTable 38 \u2013 Report format specification <\/td>\n<\/tr>\n
109<\/td>\nFigure 29 \u2013 Report example on the use of sequence number <\/td>\n<\/tr>\n
110<\/td>\nFigure 30 \u2013 Entry discard that does not cause indication of loss of information in enabled state <\/td>\n<\/tr>\n
111<\/td>\nFigure 31 \u2013 Indication of loss of information due to resource constraints in enable state <\/td>\n<\/tr>\n
112<\/td>\nFigure 32 \u2013 Data set members and reporting <\/td>\n<\/tr>\n
113<\/td>\nFigure 33 \u2013 Report example <\/td>\n<\/tr>\n
120<\/td>\nTable 39 \u2013 URCB class definition <\/td>\n<\/tr>\n
122<\/td>\n17.3 LOG-CONTROL-BLOCK class model <\/td>\n<\/tr>\n
123<\/td>\nFigure 34 \u2013 Log model overview <\/td>\n<\/tr>\n
124<\/td>\nTable 40 \u2013 LCB class definition <\/td>\n<\/tr>\n
129<\/td>\nTable 41 \u2013 LOG class definition <\/td>\n<\/tr>\n
135<\/td>\n18 Generic substation event class model (GSE)
18.1 Overview
Figure 35 \u2013 GoCB model <\/td>\n<\/tr>\n
136<\/td>\n18.2 GOOSE-CONTROL-BLOCK (GoCB) class
Table 42 \u2013 GOOSE control block class definition <\/td>\n<\/tr>\n
143<\/td>\nTable 43 \u2013 GOOSE message definition <\/td>\n<\/tr>\n
144<\/td>\n19 Transmission of sampled value class model
19.1 Overview <\/td>\n<\/tr>\n
145<\/td>\nFigure 36 \u2013 Model for transmission of sampled values <\/td>\n<\/tr>\n
146<\/td>\n19.2 Transmission of sampled values using multicast
Table 44 \u2013 MSVCB class definition <\/td>\n<\/tr>\n
151<\/td>\n19.3 Transmission of sampled values using unicast <\/td>\n<\/tr>\n
152<\/td>\nTable 45 \u2013 USVCB class definition <\/td>\n<\/tr>\n
157<\/td>\n19.4 Sampled value format <\/td>\n<\/tr>\n
158<\/td>\nTable 46 \u2013 Sampled value (SV) format definition <\/td>\n<\/tr>\n
160<\/td>\n20 CONTROL class model
20.1 Introduction
Figure 37 \u2013 Principle of the control model <\/td>\n<\/tr>\n
161<\/td>\nTable 47 \u2013 Generic behavior and negative responses <\/td>\n<\/tr>\n
162<\/td>\n20.2 Control with normal security <\/td>\n<\/tr>\n
163<\/td>\nFigure 38 \u2013 State machine of direct control with normal security <\/td>\n<\/tr>\n
164<\/td>\nFigure 39 \u2013 Direct control with normal security <\/td>\n<\/tr>\n
165<\/td>\nFigure 40 \u2013 State machine of SBO control with normal security <\/td>\n<\/tr>\n
166<\/td>\n20.3 Control with enhanced security <\/td>\n<\/tr>\n
167<\/td>\nFigure 41 \u2013 State machine of direct control with enhanced security <\/td>\n<\/tr>\n
168<\/td>\nFigure 42 \u2013 State machine SBO control with enhanced security <\/td>\n<\/tr>\n
169<\/td>\nFigure 43 \u2013 Select before operate with enhanced security \u2013 positive case
Figure 44 \u2013 Select before operate with enhanced security \u2013 negative case (no status change) <\/td>\n<\/tr>\n
170<\/td>\n20.4 Time-activated operate <\/td>\n<\/tr>\n
171<\/td>\n20.5 CONTROL class service definitions
Figure 45 \u2013 Time-activated operate
Table 48 \u2013 Control services <\/td>\n<\/tr>\n
172<\/td>\nTable 49 \u2013 T definition <\/td>\n<\/tr>\n
173<\/td>\nTable 50 \u2013 Test definition
Table 51 \u2013 Check condition definition
Table 52 \u2013 operTm definition <\/td>\n<\/tr>\n
174<\/td>\nTable 53 \u2013 Additional cause diagnosis definition <\/td>\n<\/tr>\n
175<\/td>\nTable 54 \u2013 AddCause semantic <\/td>\n<\/tr>\n
182<\/td>\n20.6 Tracking of control services <\/td>\n<\/tr>\n
183<\/td>\n21 Time and time-synchronization model
21.1 General
Table 55 \u2013 Control service tracking (CTS) definition <\/td>\n<\/tr>\n
184<\/td>\n21.2 External information
Figure 46 \u2013 Time model and time synchronization (principle) <\/td>\n<\/tr>\n
185<\/td>\n22 Naming conventions
22.1 Class naming and class specializations
Figure 47 \u2013 Specializations <\/td>\n<\/tr>\n
186<\/td>\n22.2 Referencing an instance of a class <\/td>\n<\/tr>\n
187<\/td>\n22.3 Scope
Figure 48 \u2013 Object names and object reference <\/td>\n<\/tr>\n
188<\/td>\n23 File transfer model
23.1 File class
Table 56 \u2013 FILE class definition <\/td>\n<\/tr>\n
189<\/td>\n23.2 File services <\/td>\n<\/tr>\n
192<\/td>\nAnnex A (normative) ACSI conformance statement <\/td>\n<\/tr>\n
193<\/td>\nTable A.1 \u2013 Basic conformance statement <\/td>\n<\/tr>\n
194<\/td>\nTable A.2 \u2013 ACSI models conformance statement <\/td>\n<\/tr>\n
195<\/td>\nTable A.3 \u2013 ACSI service conformance statement <\/td>\n<\/tr>\n
199<\/td>\nAnnex B (normative) Formal definition of IEC 61850-7-2 Common Data Classes <\/td>\n<\/tr>\n
207<\/td>\nAnnex C (informative) Generic substation state event (GSSE) control block (GsCB)
Figure C.1 \u2013 GsCB model <\/td>\n<\/tr>\n
208<\/td>\nTable C.1 \u2013 GSSE control block class definition <\/td>\n<\/tr>\n
214<\/td>\nTable C.2 \u2013 GSSE message definition <\/td>\n<\/tr>\n
216<\/td>\nBibliography <\/td>\n<\/tr>\n
217<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Communication networks and systems for power utility automation – Basic information and communication structure. Abstract communication service interface (ACSI)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2011<\/td>\n220<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":254717,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-254709","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/254709","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/254717"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=254709"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=254709"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=254709"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}