{"id":245645,"date":"2024-10-19T16:09:29","date_gmt":"2024-10-19T16:09:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61158-5-232019-tc\/"},"modified":"2024-10-25T11:10:05","modified_gmt":"2024-10-25T11:10:05","slug":"bs-en-iec-61158-5-232019-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61158-5-232019-tc\/","title":{"rendered":"BS EN IEC 61158-5-23:2019 – TC"},"content":{"rendered":"
IEC 61158-5-23:2019 defines the services provided to the FAL user at the boundary between the user and the application layer of the fieldbus reference model, and Systems Management at the boundary between the application layer and Systems Management of the fieldbus reference model. This standard specifies the structure and services of the IEC fieldbus application layer, in conformance with the OSI Basic Reference Model (ISO\/IEC 7498-1) and the OSI application layer structure (ISO\/IEC 9545). lt;br \/gt;This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. lt;br \/gt;This edition includes the following significant technical changes with respect to the previous edition:\u2022addition of an attribute for Master ID (see 3.2.10, 6.4.3, 6.4.4 and 6.4.5)<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
105<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | 1 Scope 1.1 General <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | 1.2 Specifications 1.3 Conformance 2 Normative references <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | 3 Terms, definitions, symbols, abbreviated terms and conventions 3.1 Referenced terms and definitions 3.1.1 ISO\/IEC 74981 terms 3.1.2 ISO\/IEC 8822 terms 3.1.3 ISO\/IEC 9545 terms <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | 3.1.4 ISO\/IEC 88241 terms 3.1.5 IEC 611581 terms 3.2 Additional Type 23 terms and definitions <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | 3.3 Symbols and abbreviated terms <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | 3.4 Conventions 3.4.1 General conventions <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | 3.4.2 Conventions for class definitions <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | 3.4.3 Conventions for service definitions <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | 4 Concept 5 Data type ASE 5.1 Overview <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | 5.2 Fixed length types 5.2.1 Bitstring types <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | 5.2.2 Numeric types <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | 6 Communication model specification 6.1 Communication model 6.1.1 General 6.1.2 Cyclic model n:n <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | 6.1.3 Cyclic model 1:n 6.1.4 Transient model Figures Figure 1 \u2013 Cyclic model (n:n type distributed shared memory, unconfirmed push model) Figure 2 \u2013 Cyclic model (1:n type distributed shared memory, unconfirmed push model) Figure 3 \u2013 Transient model (Client server model) <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | 6.2 ASE 6.2.1 Overview type C 6.2.2 Overview type F 6.2.3 Cyclic data ASE type C Figure 4 \u2013 Transient model (Push model) Figure 5 \u2013 Structure of ASE type C of FAL type 23 Figure 6 \u2013 Structure of ASE type F of FAL Type 23 <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | Tables Table 1 \u2013 Ld service parameters Table 2 \u2013 Set service parameters Table 3 \u2013 Reset service parameters <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | Table 4 \u2013 Read service parameters Table 5 \u2013 Write service parameters <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | Table 6 \u2013 Ld service parameters <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | Table 7 \u2013 Set service parameters Table 8 \u2013 Reset service parameters <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | Table 9 \u2013 Read service parameters Table 10 \u2013 Write service parameters <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | 6.2.4 Cyclic data ASE type F <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | Table 11 \u2013 Ld service parameters <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | Table 12 \u2013 Set service parameters Table 13 \u2013 Reset service parameters <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | Table 14 \u2013 Read service parameters Table 15 \u2013 Write service parameters <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | 6.2.5 Acyclic data ASE type C <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | Table 16 \u2013 Get memory access info service parameters <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | Table 17 \u2013 Run service parameters <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | Table 18 \u2013 Stop service parameters <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | Table 19 \u2013 Read memory service parameters <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | Table 20 \u2013 Write memory service parameters <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | 6.2.6 Acyclic data ASE type F <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | Table 21 \u2013 Get memory access info service parameters <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | Table 22 \u2013 Run service parameters <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | Table 23 \u2013 Stop service parameters <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | Table 24 \u2013 Read memory service parameters <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | Table 25 \u2013 Write memory service parameters <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | Table 26 \u2013 Vendor command service parameters <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | Table 27 \u2013 Distribute node info service parameters <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | Table 28 \u2013 Get statistics service parameters <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | Table 29 \u2013 Get node info detail service parameters <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | Table 30 \u2013 AC data service parameters <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | 6.2.7 Management ASE Table 31 \u2013 AC data ND service parameters <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | Table 32 \u2013 Get attribute service parameters <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | Table 33 \u2013 Set attribute service parameters <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | 6.2.8 Synchronization ASE Table 34 \u2013 Synchronization trigger service parameters <\/td>\n<\/tr>\n | ||||||
168<\/td>\n | 6.2.9 Measurement ASE Table 35 \u2013 Start measurement service parameters <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | 6.3 AR type C 6.3.1 Overview Table 36 \u2013 Get offset service parameters <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | 6.3.2 Connection Control Figure 7 \u2013 Structure of AR type C <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | 6.3.3 Cyclic transmission type C Table 37 \u2013 Control cyclic service parameters <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | Table 38 \u2013 CT Update service parameters <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | 6.3.4 Acyclic transmission type C Table 39 \u2013 AC Send service parameters <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | 6.3.5 Common parameter dist Table 40 \u2013 AC Param send service parameters <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | Table 41 \u2013 CPD Set service parameters <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | 6.4 AR type F 6.4.1 Overview 6.4.2 Channel control Figure 8 \u2013 Structure of AR type F <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | 6.4.3 Cyclic transmission type F Table 42 \u2013 Control cyclic service parameters <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | Table 43 \u2013 CT Update service parameters <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | 6.4.4 Acyclic transmission type F Table 44 \u2013 AC Send service parameters <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | Table 45 \u2013 AC Send ND service parameters <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | 6.4.5 Parameter dist <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | 6.4.6 Synchronous trigger Table 46 \u2013 Synchronous trigger internal service parameters <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | 6.4.7 Measurement transmission Table 47 \u2013 Measure send service parameters <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | Table 48 \u2013 MeasureAck send service parameters Table 49 \u2013 Offset send service parameters <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | Table 50 \u2013 Update send service parameters <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Industrial communication networks. Fieldbus specifications – Application layer service definition. Type 23 elements<\/b><\/p>\n |