{"id":189327,"date":"2024-10-19T11:55:45","date_gmt":"2024-10-19T11:55:45","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/va-energyconservationcode-2015-1stedition\/"},"modified":"2024-10-25T04:22:44","modified_gmt":"2024-10-25T04:22:44","slug":"va-energyconservationcode-2015-1stedition","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/va\/va-energyconservationcode-2015-1stedition\/","title":{"rendered":"VA EnergyConservationCode 2015 1stEdition"},"content":{"rendered":"
This is a fully integrated code based on the 2015 International Energy Conservation Code<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 2015 VIRGINIA ENERGY CONSERVATION CODE <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | 2015 VIRGINIA ENERGY CONSERVATION CODE TITLE PAGE <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | PREFACE <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | IECC\u2014COMMERCIAL PROVISIONS TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | CHAPTER 1 ADMINISTRATION SECTION 101 GENERAL SECTION 102 PURPOSE AND SCOPE SECTION 103 APPLICATION OF CODE <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | SECTION 104 ENFORCEMENT, GENERALLY SECTION 105 LOCAL BUILDING DEPARTMENT <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | SECTION 107 FEES SECTION 108 APPLICATION FOR PERMIT <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | SECTION 109 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | SECTION 110 PERMITS <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | SECTION 111 RDP SERVICES SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | SECTION 113 INSPECTIONS <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | SECTION 114 STOP WORK ORDERS <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | SECTION 115 VIOLATIONS SECTION 116 CERTIFICATES OF OCCUPANCY <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION SECTION 118 UNSAFE BUILDINGS OR STRUCTURES <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | SECTION 119 APPEALS <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | CHAPTER 2 [CE] DEFINITIONS SECTION C201 GENERAL SECTION C202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | CHAPTER 3 [CE] GENERAL REQUIREMENTS SECTION C301 CLIMATE ZONES <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | FIGURE C301.1 CLIMATE ZONES <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | TABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS SECTION C302 DESIGN CONDITIONS SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL SECTION C402 BUILDING ENVELOPE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | EQUATION 4-1 TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES EQUATION 4-2 <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHODa, <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHODa, b <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | EQUATION 4-3 TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa TABLE C402.4 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | EQUATION 4-4 EQUATION 4-5 <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | TABLE C402.4.3 SHGC ADJUSTMENT MULTIPLIERS <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | SECTION C403 BUILDING MECHANICAL SYSTEMS <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | TABLE C403.2.3(1)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | TABLE C403.2.3(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | TABLE C403.2.3(3)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS TABLE 403.2.3(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES\/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS TABLE C403.2.3(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | TABLE C403.2.3(7) WATER CHILLING PACKAGES \u2013 EFFICIENCY REQUIREMENTSa, b, d <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | TABLE C403.2.3(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS TABLE C403.2.3(10) HEAT TRANSFER EQUIPMENT EQUATION 4-6 EQUATION 4-7 <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | TABLE C403.2.7(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year) <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | TABLE C403.2.7(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year) TABLE C403.2.8 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | EQUATION 4-8 <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | TABLE C403.2.10 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | TABLE C403.2.12.1(1) FAN POWER LIMITATION TABLE C403.2.12.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | TABLE C403.2.14(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION TABLE C403.2.14(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | TABLE C403.2.14(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | TABLE C403.3(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS TABLE C403.3(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | TABLE C403.3.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS TABLE C403.3.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | TABLE C403.4.1.1 EFFECTIVE DATES FOR FAN CONTROL <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | TABLE C403.4.2.5 BOILER TURNDOWN <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | TABLE C403.4.6 MAXIMUM HOT GAS BYPASS CAPACITY <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | SECTION C404 SERVICE WATER HEATING (MANDATORY) <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | FIGURE C405.2.3.2(1) DAYLIGHT ZONE ADJACENT TO FENESTRATION IN A WALL <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | FIGURE C405.2.3.2(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR FIGURE C405.2.3.2(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | FIGURE C405.2.3.3 DAYLIGHT ZONE UNDER A ROOF FENESTRATION ASSEMBLY EQUATION 4-9 <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | EQUATION 4-10 <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | TABLE C405.4.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD TABLE C405.4.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | TABLE C405.4.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.4.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | TABLE C405.5.1(1) EXTERIOR LIGHTING ZONES <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | TABLE C405.5.1(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | TABLE C405.7 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS TABLE C405.8(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR 60 HZ NEMA GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE I) RATED 600 VOLTS OR LESS (Random Wound)a <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | TABLE C405.8(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY OF GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE II) AND ALL DESIGN B MOTORS GREATER THAN 200 HORSEPOWERa <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | TABLE C405.8(3) MINIMUM AVERAGE FULL LOAD EFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa TABLE C405.8(4) MINIMUM AVERAGE FULL LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | SECTION C407 TOTAL BUILDING PERFORMANCE <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | TABLE C407.5.1(1)\u2014continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | TABLE C407.5.1(2) HVAC SYSTEMS MAP <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | TABLE C407.5.1(4) NUMBER OF CHILLERS TABLE C407.5.1(5) WATER CHILLER TYPES SECTION C408 SYSTEM COMMISSIONING <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | CHAPTER 5 [CE] EXISTING BUILDINGS SECTION C501 GENERAL SECTION C502 ADDITIONS <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | SECTION C503 ALTERATIONS SECTION C504 REPAIRS <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | SECTION C505 CHANGE OF OCCUPANCY OR USE <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | CHAPTER 6 [CE] REFERENCED STANDARDS AAMA AHAM AHRI <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | AMCA ANSI APSP ASHRAE <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | ASME ASTM <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | CRRC CSA CTI DASMA DOE <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | ICC IEEE IES <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | ISO NEMA NFPA NFRC SMACNA <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | UL US-FTC WDMA <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | INDEX <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | IECC\u2014RESIDENTIAL PROVISIONS TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | CHAPTER 1 ADMINISTRATION SECTION 101 GENERAL SECTION 102 PURPOSE AND SCOPE SECTION 103 APPLICATION OF CODE <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | SECTION 104 ENFORCEMENT, GENERALLY SECTION 105 LOCAL BUILDING DEPARTMENT <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | SECTION 107 FEES SECTION 108 APPLICATION FOR PERMIT <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | SECTION 109 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | SECTION 110 PERMITS <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | SECTION 111 RDP SERVICES SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | SECTION 113 INSPECTIONS <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | SECTION 114 STOP WORK ORDERS <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | SECTION 115 VIOLATIONS SECTION 116 CERTIFICATES OF OCCUPANCY <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION SECTION 118 UNSAFE BUILDINGS OR STRUCTURES <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | SECTION 119 APPEALS <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | CHAPTER 2 [RE] DEFINITIONS SECTION R201 GENERAL SECTION R202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | CHAPTER 3 [RE] GENERAL REQUIREMENTS SECTION R301 CLIMATE ZONES <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | FIGURE R301.1 CLIMATE ZONES <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
168<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
171<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | TABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS SECTION R302 DESIGN CONDITIONS SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa TABLE R402.1.4 EQUIVALENT U-FACTORSa <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | SECTION R403 SYSTEMS <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | TABLE R405.5.2(1)\u2014continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE TABLE R406.4 MAXIMUM ENERGY RATING INDEXa <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | CHAPTER 5 [RE] EXISTING BUILDINGS SECTION R501 GENERAL SECTION R502 ADDITIONS <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | SECTION R503 ALTERATIONS SECTION R504 REPAIRS SECTION R505 CHANGE OF OCCUPANCY OR USE <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | CHAPTER 6 [RE] REFERENCED STANDARDS AAMA ACCA APSP ASHRAE <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | ASTM CSA DASMA ICC <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | IEEE NFPA NFRC UL US-FTC <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | WDMA <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | APPENDIX RA RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER R402.4 OR R405 CONDITIONS \u2264 5ACH50 SECTION RA101 SCOPE SECTION RA201 GENERAL DEFINITIONS SECTION RA301 TESTING PROCEDURE <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | TABLE RA301.1(1) CAZ DEPRESSURIZATION LIMITS TABLE RA301.1(2) ACCEPTABLE DRAFT TEST CORRECTION TABLE RA301.1(3) ACCEPTABLE DRAFT TEST CORRECTION <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | APPENDIX RB SOLAR-READY PROVISIONS\u2014DETACHED ONE- AND TWO-FAMILY DWELLINGS, MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES) SECTION RB101 SCOPE SECTION RB102 GENERAL DEFINITION SECTION RB103 SOLAR-READY ZONE <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | INDEX <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | ICC ASSESSMENT CENTER <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | ICC’S DIGITAL LIBRARY <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | ICC EVALUATION SERVICE <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | TURN TO ICC FOR YOUR GO-TO CODE RESOURCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Virginia Energy Conservation Code<\/b><\/p>\n |