{"id":139789,"date":"2024-10-19T08:06:39","date_gmt":"2024-10-19T08:06:39","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/vt-vermontcommercialbuildingenergystandards-2015\/"},"modified":"2024-10-25T00:19:54","modified_gmt":"2024-10-25T00:19:54","slug":"vt-vermontcommercialbuildingenergystandards-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/vt\/vt-vermontcommercialbuildingenergystandards-2015\/","title":{"rendered":"VT VermontCommercialBuildingEnergyStandards 2015"},"content":{"rendered":"
Custom code based on the Commercial provisions of the 2015 International Energy Conservation Code.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 2015 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | 2015 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS TITLE PAGE <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | PREFACE <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | EFFECTIVE USE OF THE COMMERCIAL BUILDING ENERGY STANDARDS <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | CHAPTER 1 [CE] SCOPE AND ADMINISTRATION PART 1\u2014SCOPE AND APPLICATION SECTION C101 SCOPE AND GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | SECTION C102 ALTERNATE MATERIALS\u2014METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS PART 2\u2014ADMINISTRATION AND ENFORCEMENT SECTION C103 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | SECTION C104 INSPECTIONS SECTION C105 VALIDITY <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | SECTION C106 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | CHAPTER 2 [CE] DEFINITIONS SECTION C201 GENERAL SECTION C202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | CHAPTER 3 [CE] GENERAL REQUIREMENTS SECTION C301 CLIMATE ZONE SECTION C302 DESIGN CONDITIONS SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | CHAPTER 4 COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | SECTION C402 BUILDING ENVELOPE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | TABLE C402.1 BUILDING ENVELOPE REQUIREMENTS\u2014OPAQUE ASSEMBLIES AND ELEMENTS <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | EQUATION 4-1 TABLE 402.1(2) BUILDING ENVELOPE REQUIREMENTS\u2014METAL BUILDING ASSEMBLY DESCRIPTIONS <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | TABLE C402.1(3) ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | TABLE C402.1(4) ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | TABLE C402.3 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS EQUATION 4-2 <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | EQUATION 4-3 <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | TABLE C402.4.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | SECTION C403 BUILDING MECHANICAL SYSTEMS <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | TABLE C403.2.3(1)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | TABLE C403.2.3(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS,SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | TABLE C403.2.3(3)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS TABLE 403.2.3(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES\/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | TABLE C403.2.3(7) WATER CHILLING PACKAGES \u2013 EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | TABLE C403.2.3(9)a MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS TABLE C403.2.3(10) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR CONDITIONERS <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | TABLE C403.2.3(11) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | TABLE C403.2.3(11)\u2014continued MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | EQUATION 4-4 EQUATION 4-5 <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | TABLE C403.2.7(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year) TABLE C403.2.8 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | EQUATION 4-6 <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | TABLE C403.2.10c MINIMUM PIPE INSULATION THICKNESS (in inches) <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | TABLE C403.2.12.1(1) FAN POWER LIMITATION TABLE C403.2.12.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | TABLE C403.2.14(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION TABLE C403.2.14(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | TABLE C403.2.14(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | TABLE C403.3(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | TABLE C403.3.1 DX COOLING STATESTAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | TABLE C403.3.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS TABLE C403.4.1.1 EFFECTIVE DATES FOR FAN CONTROL <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | TABLE C403.4.2.5 BOILER TURNDOWN TABLE C403.4.2.7 PIPING SYSTEM DESIGN MAXIMUM FLOW RATE IN GPM <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | TABLE C403.4.6 MAXIMUM HOT GAS BYPASS CAPACITY <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | SECTION C404 SERVICE WATER HEATING (MANDATORY) <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | FIGURE C405.2.3.2(1) DAYLIGHT ZONE ADJACENT TO FENESTRATION IN A WALL FIGURE C405.2.3.2(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | FIGURE C405.2.3.2(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR FIGURE C405.2.3.3 DAYLIGHT ZONE UNDER A ROOF FENESTRATION ASSEMBLY <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | EQUATION 4-7 <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | TABLE C405.4.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD EQUATION 4-8 <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | TABLE C405.4.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.4.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | TABLE C405.4.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.5.2(1) EXTERIOR LIGHTING ZONES <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | TABLE C405.5.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | TABLE C405.7 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | TABLE C405.8(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR 60 HZ NEMA GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE I) RATED 600 VOLTS OR LESS (Random Wound)a <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | TABLE C405.8(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY OF GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE II) AND ALL DESIGN B MOTORS GREATER THAN 200 HORSEPOWERa TABLE C405.8(3) MINIMUM AVERAGE FULL LOAD EFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | TABLE C405.8(4) MINIMUM AVERAGE FULL LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | SECTION C407 SYSTEM COMMISSIONING <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | CHAPTER 5 CE EXISTING BUILDINGS SECTION C501 GENERAL SECTION C502 ADDITIONS <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | SECTION C503 ALTERATIONS SECTION C504 REPAIRS <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | SECTION C505 CHANGE OF OCCUPANCY OR USE <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | CHAPTER 6 REFERENCED STANDARDS AAMA AHAM AHRI <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | AMCA ANSI APSP ASHRAE <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | ASME ASTM CSA <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | CTI DASMA DOE ICC <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | IEEE IES ISO NEMA NFPA <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | NFRC SMACNA UL US-FTC WDMA <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | INDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Vermont Commercial Building Energy Standards<\/b><\/p>\n |