IL – PDF Standards Store ?u= Sat, 26 Oct 2024 18:38:09 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png IL – PDF Standards Store ?u= 32 32 Illinois StateClimateSummary 2022 ?u=/product/publishers/il/illinois-stateclimatesummary-2022/ Sun, 20 Oct 2024 10:05:07 +0000 Illinois State Climate Summary
Published By Publication Date Number of Pages
IL 2022 6
]]>
None

]]>
IL 101 0369 2020:2019 Edition ?u=/product/publishers/il/il-101-0369-2020/ Sun, 20 Oct 2024 07:22:12 +0000 llinois Public Act 101-0369, Effective December 15, 2019
Published By Publication Date Number of Pages
IL 2019 16
]]>
None

]]>
IL register volume45 issue24 2021 ?u=/product/publishers/il/il-register-volume45-issue24-2021/ Sun, 20 Oct 2024 07:22:11 +0000 llinois Register Volume 45, Issue 24, Effective May 25, 2021
Published By Publication Date Number of Pages
IL 2021 351
]]>
None

PDF Catalog

PDF Pages PDF Title
1 Register Cover Vol 45_Issue24.pdf
2 register_volume45_issue_24.pdf
351 Index_Page_Vol45_Issue24.pdf
]]>
IL ChicagoBuildingCode 2019 ?u=/product/publishers/il/il-chicagobuildingcode-2019/ Sun, 20 Oct 2024 05:27:55 +0000 Chicago Building Code Title 14B - with April 2022 Supplement
Published By Publication Date Number of Pages
IL 2019
]]>
The Chicago Building Code, Title 14B regulates the new construction of buildings and structures and other building- and property-related activities, including special inspections and tests, construction site safety, and building rehabilitation work, as specifically referenced in the other Chicago Construction Codes. The accessibility-related provisions of this code have been drafted to be consistent with the 2018 Illinois Accessibility Code and federal regulations for privately-funded construction. This is a fully integrated codes based on the 2018 IBC. Effective December 1, 2019

PDF Catalog

PDF Pages PDF Title
1 Cover
2 Copyright
6 About the Chicago Construction Codes
10 Acknowledgments
18 PREFACE TO THE MODEL CODE
20 EFFECTIVE USE OF THE CHICAGO BUILDING CODE
28 TABLE OF CONTENTS
34 TABLE OF SUPPLEMENTED PROVISIONS
38 CHAPTER 1 – SCOPE AND PURPOSE
SECTION 101 GENERAL
40 CHAPTER 2 – DEFINITIONS AND MEASUREMENTS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
66 SECTION 203 MEASUREMENTS
69 CHAPTER 2 – APRIL 2022
SUPPLEMENT
SECTION 202 DEFINITIONS
SECTION 203 MEASUREMENTS
71 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
72 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
73 SECTION 306 FACTORY GROUP F
74 SECTION 307 HIGH-HAZARD GROUP H
77 SECTION 308 INSTITUTIONAL GROUP I
79 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
80 SECTION 311 STORAGE GROUP S
81 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
84 CHAPTER 3 APRIL 2022
SUPPLEMENT
SECTION 306 FACTORY GROUP F
SECTION 307 HIGH-HAZARD GROUP H
85 SECTION 308 INSTITUTIONAL GROUP I
SECTION 310 RESIDENTIAL GROUP R
SECTION 311 STORAGE GROUP S
86 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
88 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS
BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 [RESERVED] SECTION 403 HIGH-RISE BUILDINGS
91 SECTION 404 ATRIUMS
92 SECTION 405 UNDERGROUND BUILDINGS
93 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
96 SECTION 407 GROUP I-2
100 SECTION 408 GROUP I-3
102 SECTION 409 MOTION PICTURE PROJECTION ROOMS
103 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
105 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
108 SECTION 413 COMBUSTIBLE STORAGE
109 SECTION 414 [RESERVED]
SECTION 415 [RESERVED]
SECTION 416 [RESERVED]
SECTION 417 [RESERVED]
SECTION 418 [RESERVED]
SECTION 419 LIVE/WORK UNITS
110 SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
111 SECTION 421 [RESERVED]
112 SECTION 422 AMBULATORY CARE FACIILITIES
SECTION 423 [RESERVED] SECTION 424 [RESERVED] SECTION 425 [RESERVED]
SECTION 426 [RESERVED]
113 SECTION 427 [RESERVED]
SECTION 428 [RESERVED]
115 CHAPTER 4 APRIL 2022
SUPPLEMENT
SECTION 403 HIGH-RISE BUILDINGS
SECTION 405 UNDERGROUND BUILDINGS
SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
119 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
121 SECTION 417 [RESERVED]
SECTION 418 [RESERVED]
122 SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS I-1, R-1, R-2, R-3, R-4 AND R-5
123 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
124 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
127 SECTION 506 BUILDING AREA
131 SECTION 507 [RESERVED] SECTION 508 MIXED USE AND OCCUPANCY
133 SECTION 509 INCIDENTAL USES
134 SECTION 510 [RESERVED]
136 CHAPTER 5 APRIL 2022
SUPPLEMENT
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
139 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
SECTION 506 BUILDING AREA
142 SECTION 508 MIXED USE AND OCCUPANCY
143 SECTION 509 INCIDENTAL USES
146 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
SECTION 602 CONSTRUCTION CLASSIFICATION
147 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
148 SECTION 604 COMBUSTIBLE MATERIAL IN TYPES III AND IV CONSTRUCTION
SECTION 605 BASEMENT CONSTRUCTION
151 CHAPTER 6 APRIL 2022
SUPPLEMENT
SECTION 601 GENERAL
SECTION 602 CONSTRUCTION CLASSIFICATION
SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
153 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
154 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
156 SECTION 705 EXTERIOR WALLS
161 SECTION 706 FIRE WALLS
162 SECTION 707 FIRE BARRIERS
164 SECTION 708 FIRE PARTITIONS
165 SECTION 709 SMOKE BARRIERS
SECTION 710 [RESERVED] SECTION 711 FLOOR AND ROOF ASSEMBLIES
166 SECTION 712 VERTICAL OPENINGS
168 SECTION 713 SHAFT ENCLOSURES
169 SECTION 714 PENETRATIONS
172 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
173 SECTION 716 OPENING PROTECTIVES
179 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
183 SECTION 718 CONCEALED SPACES
184 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
185 SECTION 720 THERMALAND SOUND-INSULATING MATERIALS
186 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
SECTION 722 CALCULATED FIRE RESISTANCE
238 CHAPTER 7 APRIL 2022
SUPPLEMENT
SECTION 705 EXTERIOR WALLS
240 SECTION 706 FIRE WALLS
241 SECTION 707 FIRE BARRIERS
SECTION 712 VERTICAL OPENINGS
SECTION 716 OPENING PROTECTIVES SECTION 722 CALCULATED FIRE RESISTANCE
244 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
247 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
248 SECTION 806 DECORATIVE MATERIALS AND TRIM
249 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
251 CHAPTER 8 APRIL 2022
SUPPLEMENT
SECTION 803 WALL AND CEILING FINISHES
252 SECTION 804 INTERIOR FLOOR FINISH
253 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
SECTION 902 FIRE PUMP AND RISER ROOM SIZE
254 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
260 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
263 SECTION 905 STANDPIPE SYSTEMS
265 SECTION 906 PORTABLE FIRE EXTINGUISHERS
266 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
275 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
SECTION 910 SMOKE AND HEAT REMOVAL
276 SECTION 911 FIRE COMMAND CENTER
277 SECTION 912 FIRE DEPARTMENT CONNECTIONS
278 SECTION 913 FIRE PUMPS
279 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
280 SECTION 916 GAS DETECTION SYSTEMS
281 SECTION 917 [RESERVED] SECTION 918 [RESERVED] SECTION 919 CITY FIRE ALARM BOX
284 CHAPTER 9 APRIL 2022
SUPPLEMENT
SECTION 901 GENERAL
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
285 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
SECTION 905 STANDPIPE SYSTEMS
286 SECTION 906 PORTABLE FIRE EXTINGUISHERS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
288 SECTION 908 [RESERVED]
SECTION 909 SMOKE CONTROL SYSTEMS
SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 915 CARBON MONOXIDE DETECTION
289 SECTION 916 GAS DETECTION SYSTEMS
290 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
291 SECTION 1004 OCCUPANT LOAD
293 SECTION 1005 MEANS OF EGRESS SIZING
294 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
298 SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
299 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
302 SECTION 1010 DOORS, GATES AND TURNSTILES
310 SECTION 1011 STAIRWAYS
314 SECTION 1012 RAMPS
315 SECTION 1013 EXIT SIGNS
316 SECTION 1014 HANDRAILS
317 SECTION 1015 GUARDS
319 SECTION 1016 EXIT ACCESS
320 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
321 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
322 SECTION 1020 CORRIDORS
323 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
324 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
325 SECTION 1024 EXIT PASSAGEWAYS
326 SECTION 1025 [RESERVED] SECTION 1026 HORIZONTAL EXITS
327 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
328 SECTION 1028 EXIT DISCHARGE
329 SECTION 1029 ASSEMBLY
335 SECTION 1030 [RESERVED]
337 CHAPTER 10 APRIL 2022
SUPPLEMENT
SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
SECTION 1004 OCCUPANT LOAD
339 SECTION 1005 MEANS OF EGRESS SIZING
SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
342 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
SECTION 1010 DOORS, GATES AND TURNSTILES
SECTION 1011 STAIRWAYS
343 SECTION 1015 GUARDS
SECTION 1016 EXIT ACCESS
344 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
SECTION 1020 CORRIDORS
345 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
SECTION 1026 HORIZONTAL EXITS
SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
346 SECTION 1028 EXIT DISCHARGE
347 SECTION 1029 ASSEMBLY
SECTION 1031 FRONTAGE AND FIRE DEPARTMENT ACCESS REQUIREMENTS FOR GROUP E-1
349 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
351 SECTION 1102 COMPLIANCE
SECTION 1103 SCOPING REQUIREMENTS
352 SECTION 1104 ACCESSIBLE ROUTE
353 SECTION 1105 ACCESSIBLE ENTRANCES
354 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
355 SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
361 SECTION 1108 SPECIAL OCCUPANCIES
363 SECTION 1109 OTHER FEATURES AND FACILITIES
366 SECTION 1110 RECREATIONAL FACILITIES
369 SECTION 1111 SIGNAGE
372 CHAPTER 11 APRIL 2022
SUPPLEMENT
SECTION 1101 GENERAL
373 SECTION 1104 ACCESSIBLE ROUTE
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
374 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
376 SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
377 SECTION 1205 YARDS AND COURTS
378 SECTION 1206 [RESERVED] SECTION 1207 INTERIOR SPACE DIMENSIONS
379 SECTION 1208 ACCESS TO UNOCCUPIED SPACES
SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
380 SECTION 1210 RODENT PROTECTION
383 CHAPTER 12 APRIL 2022
SUPPLEMENT
SECTION 1202 VENTILATION
SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
384 SECTION 1205 YARDS AND COURTS
SECTION 1207 INTERIOR SPACE DIMENSIONS
385 SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
SECTION 1210 RODENT PROTECTION
SECTION 1211 INSECT SCREENS
386 SECTION 1212 RESIDENTIAL SECURITY DEVICES
387 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
389 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
390 SECTION 1403 MATERIALS
SECTION 1404 INSTALLATION OF WALL COVERINGS
394 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
395 SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
396 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
397 SECTION 1409 PLASTIC COMPOSITE DECKING
400 CHAPTER 14 APRIL 2022
SUPPLEMENT
SECTION 1402 PERFORMANCE REQUIREMENTS
SECTION 1404 INSTALLATION OF WALL COVERINGS
SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
402 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
SECTION 1504 PERFORMANCE REQUIREMENTS
404 SECTION 1505 FIRE CLASSIFICATION
405 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
416 SECTION 1508 ROOF INSULATION
417 SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1510 ROOFTOP STRUCTURES
419 SECTION 1511 REROOFING
SECTION 1512 [RESERVED] SECTION 1513 OCCUPIABLE ROOFTOPS
420 SECTION 1514 VEGETATIVE ROOFS, ROOF GARDEN AND LANDSCAPED ROOFS
421 SECTION 1515 SOLAR REFLECTANCE
423 CHAPTER 15 APRIL 2022
SUPPLEMENT
SECTION 1502 ROOF DRAINAGE
SECTION 1504 PERFORMANCE REQUIREMENTS
SECTION 1505 FIRE CLASSIFICATION
SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
424 SECTION 1510 UNOCCUPIED ROOFTOP STRUCTURES
SECTION 1513 OCCUPIABLE ROOFTOPS
425 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
426 SECTION 1604 GENERAL DESIGN REQUIREMENTS
429 SECTION 1605 LOAD COMBINATIONS
430 SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
437 SECTION 1608 SNOW LOADS
SECTION 1609 WIND LOADS
440 SECTION 1610 SOIL LATERAL LOADS
SECTION 1611 RAIN LOADS
SECTION 1612 FLOOD DESIGN
SECTION 1613 EARTHQUAKE LOADS
442 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 [RESERVED] SECTION 1616 STRUCTURAL INTEGRITY
446 CHAPTER 16 APRIL 2022
SUPPLEMENT
SECTION 1604 GENERAL DESIGN REQUIREMENTS
448 SECTION 1607 LIVE LOADS
450 SECTION 1609 WIND LOADS
SECTION 1611 RAIN LOADS
451 SECTION 1613 EARTHQUAKE LOADS
452 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 [RESERVED] SECTION 1703 PRODUCTS, MATERIALS AND ASSEMBLIES
453 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
455 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
462 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
463 SECTION 1709 PRECONSTRUCTION LOAD TESTS
467 CHAPTER 17 APRIL 2022
SUPPLEMENT
SECTION 1703 PRODUCTS, MATERIALS AND ASSEMBLIES
SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
469 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
471 SECTION 1804 EXCAVATION, GRADING AND FILL
472 SECTION 1805 DAMPPROOFING AND WATERPROOFING
473 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
476 SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
481 SECTION 1808 FOUNDATIONS
483 SECTION 1809 SHALLOW FOUNDATIONS
485 SECTION 1810 DEEP FOUNDATIONS
500 CHAPTER 18 APRIL 2022
SUPPLEMENT
SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
501 SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
SECTION 1808 FOUNDATIONS
SECTION 1810 DEEP FOUNDATIONS
504 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
505 SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
507 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
508 SECTION 1908 SHOTCRETE
511 CHAPTER 19 APRIL 2022
SUPPLEMENT
SECTION 1907 MINIMUM SLAB PROVISIONS
513 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
515 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
SECTION 2103 MASONRY CONSTRUCTION MATERIALS
516 SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
517 SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 [RESERVED] SECTION 2110 GLASS UNIT MASONRY
518 SECTION 2111 MASONRY FIREPLACES
520 SECTION 2112 MASONRY HEATERS
521 SECTION 2113 MASONRY CHIMNEYS
525 SECTION 2114 DRY-STACK MASONRY
528 CHAPTER 21 APRIL 2022
SUPPLEMENT
SECTION 2101 GENERAL
530 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
531 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
532 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
533 SECTION 2212 CAST IRON
535 CHAPTER 22 APRIL 2022
SUPPLEMENT
SECTION 2212 CAST IRON
537 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
541 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
554 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
556 SECTION 2306 ALLOWABLE STRESS DESIGN
557 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
601 SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
604 CHAPTER 23 APRIL 2022
SUPPLEMENT
SECTION 2303 MINIMUM STANDARDS AND QUALITY
SECTION 2306 ALLOWABLE STRESS DESIGN
605 SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
618 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
620 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
621 SECTION 2406 SAFETY GLAZING
623 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
624 SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
627 CHAPTER 24 APRIL 2022
SUPPLEMENT
SECTION 2402 [RESERVED]
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
629 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 [RESERVED] SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
630 SECTION 2507 LATHING AND PLASTERING
SECTION 2508 GYPSUM CONSTRUCTION
632 SECTION 2509 SHOWERS AND WATER CLOSETS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
633 SECTION 2511 INTERIOR PLASTER
SECTION 2512 EXTERIOR PLASTER
634 SECTION 2513 EXPOSED AGGREGATE PLASTER
635 SECTION 2514 REINFORCED GYPSUM CONCRETE
638 CHAPTER 25 APRIL 2022
SUPPLEMENT
SECTION 2508 GYPSUM CONSTRUCTION SECTION 2511 INTERIOR PLASTER
640 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
645 SECTION 2604 INTERIOR FINISH AND TRIM
646 SECTION 2605 PLASTIC VENEER
647 SECTION 2606 LIGHT-TRANSMITTING PLASTICS
648 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
649 SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
650 SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
651 SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
652 SECTION 2614 [RESERVED]
655 CHAPTER 26 APRIL 2022
SUPPLEMENT
SECTION 2603 FOAM PLASTIC INSULATION
SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
SECTION 2613 FIBER-REINFORCED POLYMER
657 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
660 CHAPTER 27 APRIL 2022
SUPPLEMENT
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
662 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
664 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
667 CHAPTER 29 APRIL 2022
SUPPLEMENT
669 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
670 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
SECTION 3005 MACHINE ROOMS
671 SECTION 3006 [RESERVED] SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
672 SECTION 3008 [RESERVED]
674 CHAPTER 30 APRIL 2022
SUPPLEMENT
SECTION 3002 HOISTWAY ENCLOSURES
676 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
677 SECTION 3103 TEMPORARY STRUCTURES
678 SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
679 SECTION 3105 AWNINGS AND CANOPIES
680 SECTION 3106 MARQUEES
SECTION 3107
RESERVED] SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
681 SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3112 GREENHOUSES
682 SECTION 3113 [RESERVED] SECTION 3114 FENCES
685 CHAPTER 31 APRIL 2022
SUPPLEMENT
SECTION 3103 TEMPORARY STRUCTURES
SECTION 3105 AWNINGS AND CANOPIES
SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
686 SECTION 3114 FENCES
687 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
690 CHAPTER 32 APRIL 2022
SUPPLEMENT
SECTION 3202 ENCROACHMENTS
692 CHAPTER 33 WORK SITE SAFETY AND OPERATIONS
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
693 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
SECTION 3307 PROTECTION OF ADJOINING PROPERTY
694 SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
695 SECTION 3313 [RESERVED] SECTION 3314 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
SECTION 3315 TEMPORARY HEATING EQUIPMENT
696 SECTION 3316 PRECAUTIONS AGAINST FIRE
SECTION 3317 FLAMMABLE AND COMBUSTIBLE LIQUIDS
697 SECTION 3318 FLAMMABLE GASES
SECTION 3319 EXPLOSIVE MATERIALS
SECTION 3320 FIRE REPORTING
SECTION 3321 MOTORIZED CONSTRUCTION EQUIPMENT
SECTION 3322 SAFEGUARDING ROOFING OPERATIONS
698 SECTION 3323 SCAFFOLDING
SECTION 3324 CONSTRUCTION SITE CLEANLINESS
701 CHAPTER 33 APRIL 2022
SUPPLEMENT
SECTION 3301 GENERAL
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3318 FLAMMABLE GASES
SECTION 3323 SCAFFOLDING
SECTION 3324 CONSTRUCTION SITE CLEANLINESS
703 CHAPTER 34 [RESERVED]
705 CHAPTER 35 REFERENCED STANDARDS
736 CHAPTER 36 APPENDICES
APPENDICES A through C [RESEREVED] APPENDIX D FIRE LIMITS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
737 SECTION D103 CHANGES TO BUILDINGS AND STRUCTURES
SECTION D104 [RESERVED] SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE LIMITS
SECTION D106 [RESERVED]
738 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
SECTION E105 OTHER FEATURES AND FACILITIES
739 SECTION E106 TELEPHONES
740 SECTION E107 SIGNAGE
SECTION E108 BUS STOPS
741 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
SECTION E110 AIRPORTS
742 SECTION E111 PUBLIC WAY
SECTION E112 REFERENCED STANDARDS
APPENDICES F through R [RESERVED]
APPENDIX S OPTIONAL SMOKE CONTROL SYSTEMS
SECTION S101 GENERAL
753 CHAPTER 36 APRIL 2022
SUPPLEMENT
APPENDIX D FIRE LIMITS APRIL 2022
SUPPLEMENT
APPENDIX S OPTIONAL SMOKE CONTROL SYSTEMS APRIL 2022
SUPPLEMENT
755 Index
A
ACCESS OPENINGS
ACCESSIBILITY
ACCESSIBLE MEANS OF EGRESS
ACCESSIBLE ROUTE
ACCESSORY OCCUPANCIES
756 ADDITION.
ADDRESS IDENTIFICATION.
ADMINISTRATION.
AEROSOL PRODUCTS.
AFFORDABLE UNIT (for Chapter 11)
AGGREGATE.
AGRICULTURAL BUILDINGS.
AIR CONDITIONING (see MECHANICAL)
AIR INTAKES (see YARDS OR COURTS)
AIRCRAFT HANGARS.
AIRCRAFT MANUFACTURING FACILITIES
AIRCRAFT-RELATED OCCUPANCIES
AISLE
ALARM SYSTEMS, EMERGENCY
ALARMS, FIRE (see FIRE ALARM AND SMOKE DETECTION SYSTEMS) ALARMS, VISIBLE
ALLOWABLE STRESS DESIGN
ALTERATIONS.
ALTERNATING TREAD DEVICES
ALTERNATIVE CODE APPROVAL
ALUMINUM.
AMBULATORY CARE FACILITIES.
AMUSEMENT BUILDING, SPECIAL
AMUSEMENT PARK STRUCTURES
ANCHORAGE.
757 APARTMENT HOUSES
APPEALS (see BUILDING BOARD OF APPEALS) ARCHITECT (see definition for REGISTERED DESIGN PROFESSIONAL) ARCHITECTURAL TRIM
AREA, BUILDING
AREA, FLOOR
AREA FOR ASSISTED RESCUE, EXTERIOR (see EXTERIOR AREAS FOR ASSISTED RESCUE) AREA OF REFUGE (see ACCESSIBLE MEANS OF EGRESS)
ASSEMBLY OCCUPANCY (GROUP A).
ASSISTED LIVING
ASSISTIVE LISTENING SYSTEM (ALS)
ATMOSPHERIC ICE LOADS
ATRIUM.
ATTIC.
758 AUDITORIUM
AUTOMOBILE PARKING GARAGE (see GARAGE, AUTOMOBILE PARKING)
AWNINGS.
B
BALCONIES
BARBECUES
BARRIERS
BASEMENT
BASEMENT WALLS
BAY AND ORIEL WINDOWS.
BED-AND-BREAKFAST ESTABLISHMENT.
BLEACHERS (see GRANDSTANDS)
BLOCK (see CONCRETE BLOCK AND GLASS UNIT MASONRY) BOARD OF APPEALS (see BUILDING BOARD OF APPEALS) BOILER ROOM
BOLTS
BONDING, MASONRY.
BRACED WALL LINE
BRACED WALL PANEL
BRICK (see MASONRY) BUILDING
759 BUILDING BOARD OF APPEALS
BUILDING HEIGHT (see HEIGHT, BUILDING) BUILDING OFFICIAL
BUILT-UP ROOFS
BUSINESS OCCUPANCY (GROUP B)
C
CABLES, STEEL STRUCTURAL.
CALCULATED FIRE RESISTANCE (see FIRE RESISTANCE, CALCULATED) CANOPIES
CARBON MONOXIDE ALARMS AND DETECTION
CARE FACILITIES (see HEALTH CARE) CARE PROVIDER STATIONS
CARE SUITES.
CARPET
CARPORT
CAST IRON
CATWALKS (see TECHNICAL PRODUCTION AREAS)
CEILING
CELLULOSE NITRATE FILM
CERAMIC TILE
CERTIFICATE OF OCCUPANCY
CHANGE OF OCCUPANCY
CHICAGO ZONING ORDINANCE
CHILD CARE (see DAY CARE)
CHILDREN’S PLAY STRUCTURES
CHIMNEYS
CIRCULAR STAIRWAYS (see CURVED STAIRWAYS) CITY DATUM.
CITY FIRE ALARM BOX.
CLAY ROOF TILE
CLINIC
760 COLD STORAGE (see FOAM PLASTIC INSULATION) COLD-FORMED STEEL.
COMBUSTIBLE DUST.
COMBUSTIBLE LIQUID.
COMBUSTIBLE LIQUIDS
COMBUSTIBLE MATERIAL
COMBUSTIBLE PROJECTIONS.
COMBUSTIBLE STORAGE.
COMMITTEE ON STANDARDS AND TESTS
COMMON PATH OF EGRESS TRAVEL
COMPARTMENTATION
COMPLIANCE ALTERNATIVES
COMPRESSED GAS
CONCEALED SPACES
CONCRETE
CONCRETE MASONRY
CONCRETE ROOF TILE
CONDUIT, PENETRATION PROTECTION
CONGREGATE LIVING FACILITIES.
CONSTRUCTION (see SAFEGUARDS DURING CONSTRUCTION) CONSTRUCTION DOCUMENTS
CONSTRUCTION EQUIPMENT, MOTORIZED
CONSTRUCTION JOINTS
CONSTRUCTION SITE CLEANLINESS
CONSTRUCTION TYPES.
761 CONTRACTOR’S RESPONSIBILITIES
CONTROL AREA
CONVENTIONAL LIGHT-FRAME CONSTRUCTION.
CONVEYANCE DEVICES.
CORNICES
CORRIDOR (see CORRIDOR PROTECTION, EXIT ACCESS, FIRE PARTITIONS and SERVICE CORRIDORS)
CORRIDOR PROTECTION, EXIT ACCESS
CORROSIVES
COURTS (see YARDS OR COURTS)
COVERED WALKWAY (see PEDESTRIAN WALKWAY)
CRAWL SPACE
CRIPPLE WALL
CROSS-LAMINATED TIMBER
CRYOGENIC
D
DAMPERS (see FIRE DAMPERS AND SMOKE DAMPERS)
DAMPPROOFING AND WATERPROOFING
DAY CARE
DAY SURGERY CENTER (see AMBULATORY CARE FACILITIES) DEAD END
DEAD LOAD
DECK
DEFLECTIONS
DEMOLITION.
762 DESIGN STRENGTH
DESIGNATED SEISMIC SYSTEM.
DIAPHRAGMS
DISABILITY (for Chapter 11)
DOORS.
DORMITORIES.
DRAINAGE.
DRAFTSTOPPING
DRINKING FOUNTAINS.
DUCTS AND AIR TRANSFER OPENINGS (see MECHANICAL) DUMBWAITERS.
DWELLING UNITS
E
EARTHQUAKE LOADS (see SEISMIC)
EAVES (see COMBUSTIBLE PROJECTIONS AND CORNICES) EDUCATIONAL OCCUPANCY (GROUP E)
EGRESS (see MEANS OF EGRESS)
ELECTRICAL
763 ELEVATOR
EMERGENCY COMMUNICATIONS
EMERGENCY LIGHTING
EMERGENCY TELEPHONE.
EMERGENCY POWER
EMERGENCY RESPONDERS
EMPIRICAL DESIGN OF MASONRY
EMPLOYEE
ENCROACHMENTS INTO THE PUBLIC WAY
END-JOINTED LUMBER
ENERGY EFFICIENCY
ENFORCEMENT
ENGINEER (see definition for REGISTERED DESIGN PROFESSIONAL) EQUIPMENT PLATFORM.
ESCALATORS
ESSENTIAL FACILITIES (see RISK CATEGORY).
EXCAVATION, GRADING AND FILL
EXHIBITION AREA
EXISTING BUILDING
EXIT (see MEANS OF EGRESS)
764 EXIT ACCESS (see MEANS OF EGRESS).
EXIT DISCHARGE (see MEANS OF EGRESS)
EXIT PASSAGEWAY (see MEANS OF EGRESS)
EXIT SIGNS
EXPLOSIVE MATERIALS
EXPOSURE CATEGORY (see WIND LOAD).
EXTERIOR AREAS FOR ASSISTED RESCUE
EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
EXTERIOR WALLS (see WALLS, EXTERIOR).
F
FACTORY OCCUPANCY (GROUP F)
FEES.
FENCE
FIBERBOARD
FILL MATERIAL
FINGER-JOINTED LUMBER (see END-JOINTED LUMBER) FIRE ALARM AND SMOKE DETECTION SYSTEMS
765 FIRE ALARM BOX, CITY
FIRE ALARM BOX, MANUAL
FIRE AREA
FIRE BARRIERS.
FIRE CODE OFFICIAL
FIRE COMMAND CENTER.
FIRE DAMPERS
FIRE DEPARTMENT (see EMERGENCY RESPONDERS) FIRE DETECTION SYSTEM (see FIRE ALARM AND SMOKE DETECTION SYSTEMS) FIRE DOOR (see OPE
FIRE EXTINGUISHERS, PORTABLE.
FIRE EXTINGUISHING SYSTEMS
FIRE LIMITS
FIRE PARTITION.
FIRE PROTECTION
FIRE PROTECTION, OWNER’S RESPONSIBILITY
FIRE PROTECTION SYSTEMS
FIRE PUMPS
FIRE RESISTANCE
766 FIRE RESISTANCE, CALCULATED
FIRE-RESISTANT CONSTRUCTION
FIRE-RETARDANT-TREATED WOOD
FIRE SEPARATION DISTANCE
FIRE SERVICE ACCESS ELEVATORS
FIRE SHUTTER (see OPENING PROTECTIVES)
FIRE WALLS
FIRE WINDOWS (see OPENING PROTECTIVES) FIREBLOCKING.
FIRE WATCH DURING CONSTRUCTION.
FIREPLACES, FACTORY-BUILT
FIREPLACES, MASONRY
FIREWORKS
FLAMESPREAD.
FLAMMABLE GAS.
FLAMMABLE FINISHES
FLAMMABLE LIQUID
FLAMMABLE SOLID
FLASHING
FLOOD HAZARD AREAS
FLOOD-RESISTANT CONSTRUCTION
FLOOR AREA (see AREA, FLOOR) FLOOR CONSTRUCTION (see FLOOR CONSTRUCTION, WOOD)
FLOOR CONSTRUCTION, WOOD
767 FLOOR LEVEL
FLOOR LOADS
FLOOR OPENING PROTECTION (see VERTICAL OPENING PROTECTION) FLOOR/CEILING (see FLOOR CONSTRUCTION) FOAM PLASTICS
FOLDING AND TELESCOPIC SEATING
FOUNDATION (see FOUNDATION, DEEP and FOUNDATION, SHALLOW).
FOUNDATION, DEEP
FOUNDATION, SHALLOW.
FOYERS
FRATERNITIES.
FROST PROTECTION
FURNACE ROOMS.
G
GALLERIES (see TECHNICAL PRODUCTION AREAS) GARAGE, AUTOMOBILE PARKING (see PARKING GARAGES) GARAGE, REPAIR
GARAGES, TRUCK AND BUS
GARAGES AND CARPORTS, PRIVATE
768 GAS
GATES
GIFT SHOPS
GIRDERS
GLASS (see GLAZING) GLASS BLOCK (see GLASS UNIT MASONRY) GLASS UNIT MASONRY.
GLAZING
GRADE, LUMBER (see LUMBER)
GRADE PLANE
GRANDSTANDS (see BLEACHERS)
GREENHOUSES
GRIDIRON (see TECHNICAL PRODUCTION AREAS) GROSS FLOOR AREA (see AREA, FLOOR) GROUT
GUARDS.
GUTTERS
GYMNASIUMS
GYPSUM.
769 H
HANDRAILS
HARDBOARD
HARDWARE (see DOORS and LOCKS AND LATCHES) HARDWOOD
HAZARDOUS MATERIALS
HAZARDOUS OCCUPANCY (GROUP H), (see HAZARDOUS MATERIALS)
770 HEAD JOINT, MASONRY
HEADROOM.
HEALTH CARE (see INSTITUTIONAL I-1 AND INSTITUTIONAL I-2)
HEALTH-HAZARD MATERIALS
HEAT VENTS
HEATING (see MECHANICAL)
HEIGHT, BUILDING
HELIPORT
HIGHER EDUCATION LABORATORIES
HIGH-PILED COMBUSTIBLE STORAGE
HIGH-PRESSURE DECORATIVE EXTERIORGRADE COMPACT LAMINATES.
HIGH-RISE BUILDINGS.
HISTORIC BUILDINGS
HORIZONTAL ASSEMBLY
HORIZONTAL EXIT
HORIZONTAL FIRE SEPARATION (see HORIZONTAL ASSEMBLY) HOSE CONNECTIONS (see STANDPIPES, REQUIRED) HOSPITAL (see INSTITUTIONAL I-2
HURRICANE-PRONE REGIONS (see WIND LOADS).
HURRICANE SHELTER (see STORM SHELTER) HYDROGEN FUEL GAS ROOM
I
ICE-SENSITIVE STRUCTURE
771 IDENTIFICATION, REQUIREMENTS FOR
ILLINOIS ACCESSIBILITY CODE
IMPACT LOAD
INCIDENTAL USES
INCINERATOR ROOMS
INDUSTRIAL (see FACTORY OCCUPANCY) INSPECTIONS.
INSPECTIONS, SPECIAL (see SPECIAL INSPECTIONS AND TESTS) INSTITUTIONAL I-1 [see INSTITUTIONAL OCCUPANCY (GROUP I) and RESIDENTIA
INSTITUTIONAL I-2 [see INSTITUTIONAL OCCUPANCY (GROUP I)]
INSTITUTIONAL I-3 [see INSTITUTIONAL OCCUPANCY (GROUP I)]
INSTITUTIONAL I-4 [see INSTITUTIONAL OCCUPANCY (GROUP I)]
772 INSTITUTIONAL OCCUPANCY (GROUP I)
INSULATION
INTERIOR ENVIRONMENT
INTERIOR FINISHES
J
JAILS (see INSTITUTIONAL I-3)
JOINT
JOINTS, FIRE-RESISTANT SYSTEMS
K
KITCHENS
L
LABORATORIES
LADDERS
773 LAMINATED TIMBER, STRUCTURAL GLUED
LANDSCAPED ROOFS
LANDINGS
LATH, METAL OR WIRE
LAUNDRIES
LAUNDRY CHUTE
LIBRARIES
LIGHT, REQUIRED
LIGHT-FRAME CONSTRUCTION
LIGHTS, PLASTIC CEILING DIFFUSERS
LINEN CHUTE.
LINTEL
LIVE LOADS
LIVE/WORK UNITS.
LOAD AND RESISTANCE FACTOR DESIGN (LRFD).
LOAD COMBINATIONS
LOADS.
LOBBIES
LOCKS AND LATCHES
LODGING HOUSES
LOFTS
LOW-SLOPED ROOF
LUMBER
M
MAINTENANCE
MANUAL FIRE ALARM BOX
MARQUEES
774 MASONRY
MATERIALS
MEANS OF EGRESS.
775 MEASUREMENTS
MECHANICAL (see AIR CONDITIONING, HEATING, REFRIGERATION, AND VENTILATION)
MECHANICALLY LAMINATED DECKING.
MEMBRANE ROOF COVERINGS
MEMBRANE STRUCTURES
MENTAL HOSPITALS (see INSTITUTIONAL I-2) MERCANTILE OCCUPANCY (GROUP M).
METAL
METAL COMPOSITE MATERIALS
MEZZANINES
MIRRORS
MIXED OCCUPANCY (see OCCUPANCY SEPARATION) MODIFICATIONS
MOISTURE PROTECTION
MONASTERIES.
MORTAR
MOTION PICTURE PROJECTION ROOMS.
776 MOTOR FUEL-DISPENSING SYSTEM.
MOTOR VEHICLE FACILITIES
MOTORIZED CONSTRUCTION EQUIPMENT (see CONSTRUCTION EQUIPMENT, MOTORIZED) MOVING, BUILDINGS
MOVING WALKS
MULTI-STORY HOUSING (for Chapter 11)
N
NAILING
NATURAL LIGHT.
NATURAL VENTILATION
NET FLOOR AREA (see AREA, FLOOR) NONCOMBUSTIBLE BUILDING MATERIAL
NURSES STATIONS (See CARE PROVIDER STATIONS) NURSING HOMES (see INSTITUTIONAL, GROUP I-2)
O
OCCUPANCY
OCCUPANCY CLASSIFICATION
OCCUPANCY SEPARATION
OCCUPANT LOAD
OCCUPIABLE ROOFTOPS
OFFICE BUILDINGS [see BUSINESS OCCUPANCY (GROUP B)]
OPENING PROTECTION, EXTERIOR WALLS.
OPENING PROTECTION, FLOORS (see VERTICAL OPENING PROTECTION) OPENING PROTECTIVES
ORGANIC PEROXIDE
OWNER’S RESONSIBILITY FOR FIRE PROTECTION
OXIDIZERS, LIQUID AND SOLID
P
PANIC HARDWARE.
PARAPET, EXTERIOR WALL
PARKING, ACCESSIBLE.
PARKING FACILITIES
PARKING GARAGES.
777 PARKING GARAGES, ENCLOSED
PARKING GARAGES, OPEN.
PARTICLEBOARD
PARTITIONS
PARTY WALLS (see FIRE WALLS)
PASSAGEWAY, EXIT (see EXIT).
PASSENGER STATIONS
PATIO COVERS
PEDESTRIAN
PENALTIES.
PENETRATION-FIRESTOP SYSTEM
PENETRATIONS.
PENTHOUSE.
PERFORMANCE CATEGORY
PERLITE
PERMIT
PHOTOVOLTAIC PANEL SYSTEMS
PIER FOUNDATIONS (see FOUNDATION, SHALLOW) PILE FOUNDATIONS (see FOUNDATION, DEEP) PIPES
PLAIN CONCRETE (see CONCRETE).
PLANNED DEVELOPMENT
PLASTER
778 PLASTIC.
PLASTIC, FOAM
PLASTIC, LIGHT-TRANSMITTING
PLATFORM (see STAGES AND PLATFORMS)
PLATFORM, EQUIMENT (see EQUIPMENT PLATFORM) PLATFORM LIFTS, WHEELCHAIR
PLUMBING.
PLYWOOD (see WOOD STRUCTURAL PANELS).
PRECAUTIONS AGAINST FIRE
PRESCRIPTIVE FIRE RESISTANCE
PRESERVATIVE-TREATED WOOD
PRIVATE GARAGE
PROJECTION ROOMS
PROJECTIONS, COMBUSTIBLE
PROPERTY LINE (see FIRE SEPARATION DISTANCE)
PROPERTY MAINTENANCE.
PROSCENIUM
PSYCHIATRIC HOSPITALS (see INSTITUTIONAL I-2)
PUBLIC PROPERTY
PUBLIC WAY
PYROPHORIC MATERIALS
R
RAILING (see GUARDS AND HANDRAILS) RAMPS
RECREATIONAL FACILITIES
779 REFERENCED STANDARDS.
REFORMATORIES
REFRIGERATION (see MECHANICAL)
REFUGE AREAS (see HORIZONTAL EXIT, SMOKE COMPARTMENTS, STORM SHELTERS)
REFUSE CHUTE.
REINFORCED CONCRETE (see CONCRETE)
REINFORCEMENT
RELOCATING, BUILDING (see MOVED BUILDING) REPAIR
REROOFING
RESIDENTIAL OCCUPANCY (GROUP R).
RETAINING WALLS
REVIEWING STANDS (see BLEACHERS AND GRANDSTANDS) RISERS, STAIR (see STAIRWAY CONSTRUCTION)
RISK CATEGORY (Structural Design)
RODENT PROTECTION
ROLL ROOFING
ROOF ACCESS.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES.
780 ROOF CONSTRUCTION
ROOF CONSTRUCTION, WOOD
ROOF COVERINGS.
ROOF DECK.
ROOF DRAINAGE
ROOF GARDENS.
ROOF RECOVER
ROOF REFLECTANCE (see SOLAR REFLECTANCE) ROOF REPAIR
ROOF REPLACEMENT
ROOF STRUCTURE (see ROOF ASSEMBLIES AND ROOFTOP STRUCTURES, OCCUPIABLE ROOFTOPS) ROOFING OPERATIONS.
ROOM DIMENSIONS
S
SAFEGUARDS DURING CONSTRUCTION.
781 SAFETY GLAZING
SCAFFOLDING.
SCHOOLS (see EDUCATIONAL OCCUPANCY) SEATING
SEATING, FIXED
SECURITY GLAZING
SECURITY GRILLES
SEISMIC
SERVICE SINKS
SERVICE STATION (see MOTOR FUEL-DISPENSING FACILITIES) SHAFT (see SHAFT ENCLOSURE AND VERTICAL OPENING PROTECTION)
SHAFT ENCLOSURE (see VERTICAL OPENING PROTECTION)
SHEAR WALL
SHEATHING
SHOTCRETE.
SHUTTERS, FIRE (see OPENING PROTECTIVES)
SIGNS
782 SINGLE-WYTHE EXTERIOR WALLS
SITE WORK
SKYLIGHTS
SLAB ON GROUND, CONCRETE.
SLATE SHINGLES.
SLEEPING UNIT.
SMOKE ALARMS
SMOKE BARRIERS.
SMOKE COMPARTMENT
SMOKE CONTROL
SMOKE DAMPERS
SMOKE DETECTION SYSTEM (see FIRE ALARM AND SMOKE DETECTION SYSTEMS).
SMOKE DETECTORS
SMOKE DEVELOPMENT.
SMOKE EXHAUST SYSTEMS
SMOKE REMOVAL (High rise)
SMOKE VENTS
SMOKEPROOF ENCLOSURES
SNOW LOAD
SOILS AND FOUNDATIONS (see FOUNDATION)
SOLAR ENERGY SYSTEMS
SOLAR REFLECTANCE
SORORITIES
SOUND-INSULATING MATERIALS (see INSULATION)
SPECIAL CONSTRUCTION.
783 SPECIAL INSPECTIONS AND TESTS (see INSPECTIONS)
SPECIAL INSPECTOR
SPIRAL STAIRWAYS
SPORTS ACTIVITY, AREA OF (see RECREATIONAL FACILITIES)
SPRAYED FIRE-RESISTANT MATERIALS.
SPRINKLER SYSTEM, AUTOMATIC.
SPRINKLER SYSTEM, REQUIRED
SPRINKLER SYSTEM, SUPERVISION
STAGES AND PLATFORMS
784 STAIRWAY (see ALTERNATING TREAD DEVICES, SPIRAL STAIRWAYS, STAIRWAY CONSTRUCTION and STAIRWAY ENCLOSURE) STAIRWAY CONSTRUCTION
STAIRWAY ENCLOSURE
STANDARDS (see REFERENCED STANDARDS) STANDBY POWER
STANDPIPE AND HOSE SYSTEMS (see STANDPIPES, REQUIRED)
STANDPIPES, REQUIRED
STEEL.
785 STONE VENEER.
STOP WORK ORDER.
STORAGE OCCUPANCY (GROUP S)
STOREROOMS.
STRENGTH
STRENGTH DESIGN
STRUCTURAL DESIGN
STRUCTURAL OBSERVATION
STUCCO
SUSCEPTIBLE BAY
SWIMMING POOL.
T
TECHNICAL PRODUCTION AREAS
TELECOMMUNICATIONS EQUIPMENT AREA
TELEPHONE EXCHANGES
TELESCOPIC SEATING (see FOLDING AND TELESCOPIC SEATING) TEMPORARY HEATING EQUIPMENT.
TEMPORARY STRUCTURES.
TENTS (see TEMPORARY STRUCTURES) TERMITES, PROTECTION FROM
TERRA COTTA
TESTING
786 THEATERS [see ASSEMBLY OCCUPANCY (GROUP A), PROJECTION ROOMS and STAGES AND PLATFORMS]
THERMAL BARRIER, FOAM PLASTIC INSULATION.
THERMAL-INSULATING MATERIALS (see INSULATION)
TILE
TOILETS and TOILET ROOMS.
TOWERS
TOXIC MATERIALS [see HIGH-HAZARD OCCUPANCY (GROUP H)]
TRANSITIONAL PROVISIONS
TRANSPORTATION
TRAVEL DISTANCE
TREADS, STAIR (see STAIRWAY CONSTRUCTION)
TREATED WOOD.
TRUSSES
TUNNELED WALKWAY.
TURNSTILES
U
UNDERGROUND BUILDINGS.
UNDERLAYMENT
UNSTABLE MATERIALS.
UNUSABLE SPACE.
USE AND OCCUPANCY
UTILITY AND MISCELLANEOUS OCCUPANCY (GROUP U)
787 V
VEGETATIVE ROOFS
VEHICLE BARRIER SYSTEMS
VEHICLE SHOW ROOMS.
VEHICULAR FUELING
VEHICULAR GATES.
VEHICULAR REPAIR
VEHICULAR WAY (for Chapter 11).
VENEER
VENTILATION (see MECHANICAL)
VENTS, PENETRATION PROTECTION.
VERTICAL OPENING PROTECTION
VESTIBULES, EXIT DISCHARGE
VESTIBULE, WEATHER PROTECTED
VINYL
VIOLATIONS
W
WALKWAY
WALL, EXTERIOR
788 WALL, FIRE (see FIRE WALLS) WALL, FOUNDATION (see FOUNDATION) WALL, INTERIOR
WALL, INTERIOR NONBEARING (see PARTITIONS) WALL, MASONRY
WALL, PARAPET.
WALL, PARTY (see FIRE WALLS) WALL, PENETRATIONS
WALL, RETAINING (see RETAINING WALL) WALL, VENEERED (see VENEER).
WALL, WOOD CONSTRUCTION
WATER-REACTIVE MATERIALS
WEATHER PROTECTION
WELDING.
WIND LOAD
WINDERS, STAIR (see STAIRWAY CONSTRUCTION) WINDOW
WIRES, PENETRATION PROTECTION
WOOD.
789 WOOD SHINGLES AND SHAKES
WOOD STRUCTURAL PANELS (see WOOD).
Y
YARDS OR COURTS
793 CAUTION NOTICE:
795 Development
2009 Edition
ANSI Approval
Adoption
Formal Interpretations
796 Maintenance—Submittal of Proposals
Marginal Markings
Marginal Markings—Chicago
797 Accredited Standards Committee A117 on Architectural Features and Site Design of Public Buildings and Residential Structures for
800 Builder/Owner/Operator (BO)
Consumer/User (CU)
Producer/Distributor (PD)
Professional (P)
Regulatory (R)
Individual Expert (IE)
Category Number
BO)
CU)
P)
PD)
TOTAL 46
801 Chapter 1. Application and Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Chapter 2. Scoping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 3. Building Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 4. Accessible Routes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 5. General Site and Building Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
802 Chapter 6. Plumbing Elements and Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Chapter 7. Communication Elements and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Chapter 8. Special Rooms and Spaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Chapter 9. Built-In Furnishings and Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Chapter 10. Dwelling Units and Sleeping Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
803 Chapter 11. Recreational Facilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
805 Chapter 1. Application and Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Chapter 2. Scoping
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Chapter 3. Building Block
Chapter 4. Accessible Routes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
806 Chapter 5. General Site and Building Elements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Chapter 6. Plumbing Elements and Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
808 Chapter 7. Communication Elements and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Chapter 8. Special Rooms and Spaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Chapter 9. Built-In Furnishings and Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Chapter 10. Dwelling Units and Sleeping Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
809 Chapter 11. Recreational Facilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
811 101 Purpose
101.1 Applicability.
102 Anthropometric Provisions
103 Compliance Alternatives
104 Conventions 104.1 General.
104.2 Dimensions.
104.3 Figures.
104.4 Floor or Floor Surface.
104.5 Referenced Sections.
105 Referenced Documents 105.1 General.
105.2 Documents. 105.2.1 Manual on Uniform Traffic Control Devices:
105.2.2 National Fire Alarm Code:
105.2.3 Power Assist and Low Energy Power Operated Doors:
105.2.4 Power Operated Pedestrian Doors:
105.2.5 Safety Code for Elevators and Escalators:
812 105.2.6 Safety Standard for Platform Lifts and Stairway Chairlifts:
105.2.7 Performance Criteria for Accessible Communications Entry Systems.
105.2.8 Standard Specification for Impact Attenuation of Surface Systems Under and Around Playground Equipment
105.2.9 Standard Specification for Impact Attenuation of Surfacing Materials Within the Use Zone of Playground Equipment
105.2.10 Standard Consumer Safety Performance Specification for Playground Equipment for Public Use
813 105.2.11 Americans with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles
106 Definitions 106.1 General.
106.2 Terms Defined in Referenced Documents.
106.3 Undefined Terms.
106.4 Interchangeability.
106.5 Defined Terms. accessible:
administrative authority:
amusement attraction:
amusement ride:
amusement ride seat:
area of sport activity:
boarding pier:
boat launch ramp:
boat slip:
catch pool:
characters:
children’s use:
circulation path:
counter slope:
cross slope:
curb ramp:
destination-oriented elevator system:
detectable warning:
dwelling unit:
element:
elevated play component:
elevator car call sequential step scanning:
facility:
gangway:
golf car passage:
ground level play component:
habitable:
key surface:
814 marked crossing:
operable part:
pictogram:
play area:
play component:
ramp:
running slope:
sign:
site:
sleeping unit:
soft contained play structure:
teeing ground:
transfer device:
TTY:
use zone:
variable message signs (VMS):
variable message sign (VMS) characters:
vehicular way:
walk:
wheelchair space:
wheelchair space locations:
815 201 General
202 Dwelling and Sleeping Units
203 Administration
817 301 General 301.1 Scope.
301.2 Overlap.
302 Floor Surfaces 302.1 General.
302.2 Carpet.
302.3 Openings.
303 Changes in Level 303.1 General.
303.2 Vertical.
303.3 Beveled.
303.4 Ramps.
304 Turning Space 304.1 General.
818 304.2 Floor Surface.
EXCEPTION:
304.3 Size.
304.3.1 Circular Space.
304.3.2 T-Shaped Space.
304.4 Door Swing.
305 Clear Floor Space 305.1 General.
305.2 Floor Surfaces.
EXCEPTION:
305.3 Size.
305.4 Knee and Toe Clearance.
305.5 Position.
305.6 Approach.
305.7 Alcoves.
305.7.1 Parallel Approach.
305.7.2 Forward Approach.
819 306 Knee and Toe Clearance 306.1 General.
306.2 Toe Clearance. 306.2.1 General.
306.2.2 Maximum Depth.
306.2.3 Minimum Depth.
306.2.4 Additional Clearance.
306.2.5 Width.
306.3 Knee Clearance. 306.3.1 General.
306.3.2 Maximum Depth.
306.3.3 Minimum Depth.
306.3.4 Clearance Reduction.
306.3.5 Width.
307 Protruding Objects 307.1 General.
821 307.2 Protrusion Limits.
EXCEPTION:
307.3 Post-Mounted Objects.
EXCEPTION:
307.4 Vertical Clearance.
EXCEPTION:
307.5 Required Clear Width.
308 Reach Ranges 308.1 General.
308.2 Forward Reach. 308.2.1 Unobstructed.
308.2.2 Obstructed High Reach.
823 308.3 Side Reach. 308.3.1 Unobstructed.
EXCEPTION:
308.3.2 Obstructed High Reach.
824 EXCEPTION:
309 Operable Parts 309.1 General.
309.2 Clear Floor Space.
309.3 Height.
309.4 Operation.
EXCEPTION:
825 401 General 401.1 Scope.
402 Accessible Routes 402.1 General.
402.2 Components.
402.3 Revolving Doors, Revolving Gates, and Turnstiles
403 Walking Surfaces 403.1 General.
403.2 Floor Surface.
403.3 Slope.
403.4 Changes in Level.
403.5 Clear Width.
EXCEPTION:
403.5.1 Clear Width at 180 Degree Turn.
EXCEPTION:
403.5.2 Passing Space.
403.6 Handrails.
404 Doors and Doorways 404.1 General.
404.2 Manual Doors.
EXCEPTION:
826 404.2.1 Double-Leaf Doors and Gates.
404.2.2 Clear Width.
827 EXCEPTIONS:
404.2.3 Maneuvering Clearances.
404.2.3.1 Floor Surface.
404.2.3.2 Swinging Doors.
404.2.3.3 Sliding and Folding Doors.
829 404.2.3.4 Doorways without Doors.
404.2.3.5 Recessed Doors.
404.2.4 Thresholds.
EXCEPTION:
404.2.5 Two Doors in Series.
404.2.6 Door Hardware.
EXCEPTION:
404.2.7 Closing Speed. 404.2.7.1 Door Closers.
404.2.7.2 Spring Hinges.
830 404.2.8 Door-Opening Force.
404.2.9 Door Surface.
EXCEPTIONS:
831 404.2.10 Vision Lites.
EXCEPTION:
404.3 Automatic Doors.
EXCEPTION:
404.3.1 Clear Width.
832 404.3.2 Maneuvering Clearances.
404.3.3 Thresholds.
404.3.4 Two Doors in Series.
404.3.5 Control Switches.
405 Ramps 405.1 General.
EXCEPTION:
405.2 Slope.
EXCEPTION:
405.3 Cross Slope.
405.4 Floor Surfaces.
405.5 Clear Width.
405.6 Rise.
405.7 Landings.
405.7.1 Slope.
405.7.2 Width.
405.7.3 Length.
405.7.4 Change in Direction.
405.7.5 Doorways.
405.8 Handrails.
833 405.9 Edge Protection.
EXCEPTIONS:
405.9.1 Extended Floor Surface.
405.9.2 Curb or Barrier.
405.9.2.1 Curb.
405.9.2.2 Barrier.
405.10 Wet Conditions.
834 406 Curb Ramps 406.1 General.
406.2 Counter Slope.
406.3 Sides of Curb Ramps.
406.3.1 Slope.
406.3.2 Marking.
406.4 Width.
406.5 Floor Surface.
406.6 Location.
835 406.7 Landings.
EXCEPTION:
406.8 Obstructions.
406.9 Handrails.
406.10 Diagonal Curb Ramps.
836 406.11 Islands.
406.12 Detectable Warnings at Raised Marked Crossings.
406.13 Detectable Warnings at Curb Ramps.
406.13.1 Area Covered.
406.13.2 Location.
406.14 Detectable Warnings at Islands or Cutthrough Medians.
407 Elevators 407.1 General.
407.2 Elevator Landing Requirements.
407.2.1 Call Controls.
EXCEPTIONS:
407.2.1.1 Height.
837 EXCEPTION:
407.2.1.2 Size.
EXCEPTION:
407.2.1.3 Clear Floor Space.
407.2.1.4 Location.
EXCEPTION:
407.2.1.5 Signals.
EXCEPTIONS:
407.2.1.6 Keypads.
407.2.1.7 Destination-oriented Elevator Signals
838 407.2.2 Hall Signals.
407.2.2.1 Visible and Audible Signals.
EXCEPTIONS:
407.2.2.2 Visible Signals.
EXCEPTIONS:
407.2.2.3 Audible Signals.
EXCEPTIONS:
407.2.2.4 Differentiation.
407.2.3 Hoistway Signs.
407.2.3.1 Floor Designation.
407.2.3.2 Car Identification.
839 407.2.4 Destination Signs.
EXCEPTION:
407.3 Elevator Door Requirements.
407.3.1 Type.
407.3.2 Operation.
EXCEPTION:
407.3.3 Reopening Device.
EXCEPTION:
407.3.3.1 Height.
407.3.3.2 Contact.
407.3.3.3 Duration.
407.3.4 Door and Signal Timing.
EXCEPTIONS:
407.3.5 Door Delay.
407.3.6 Width.
EXCEPTION:
840 407.4 Elevator Car Requirements.
407.4.1 Inside Dimensions.
EXCEPTION:
407.4.2 Floor Surfaces.
407.4.3 Platform to Hoistway Clearance.
407.4.4 Leveling.
407.4.5 Illumination.
407.4.6 Elevator Car Controls.
EXCEPTION:
407.4.6.1 Location.
EXCEPTIONS: 1.
407.4.6.2 Buttons.
EXCEPTION:
407.4.6.2.1 Size.
407.4.6.2.2 Arrangement.
407.4.6.3 Keypads.
407.4.6.4 Emergency Controls.
407.4.6.4.1 Height.
841 407.4.6.4.2 Location.
407.4.7 Designations and Indicators of Car Controls
EXCEPTIONS:
407.4.7.1 Buttons.
407.4.7.1.1 Type.
407.4.7.1.2 Location.
842 EXCEPTION:
407.4.7.1.3 Symbols.
407.4.7.1.4 Visible Indicators.
407.4.7.2 Keypads.
407.4.8 Elevator Car Call Sequential Step Scanning
407.4.9 Car Position Indicators.
407.4.9.1 Visible Indicators.
407.4.9.1.1 Size.
407.4.9.1.2 Location.
407.4.9.1.3 Floor Arrival.
EXCEPTION:
407.4.9.1.4 Destination Indicator.
407.4.9.2 Audible Indicators.
407.4.9.2.1 Signal Type.
EXCEPTION:
407.4.9.2.2 Signal Level.
407.4.9.2.3 Frequency.
407.4.10 Emergency Communications.
407.4.10.1 Height.
407.4.10.2 Identification.
408 Limited-use/Limited-application Elevators 408.1 General.
408.2 Elevator Landing Requirements.
408.2.1 Call Controls.
408.2.2 Hall Signals.
408.2.3 Hoistway Signs.
844 408.3 Elevator Door Requirements.
408.3.1 Sliding Doors.
408.3.2 Swinging Doors.
408.3.2.1 Power Operation.
408.3.2.2 Duration.
408.3.3 Door Location and Width.
408.3.3.1 Cars with Single Door or Doors on Opposite Ends.
408.3.3.2 Cars with Doors on Adjacent Sides.
EXCEPTION:
408.4 Elevator Car Requirements.
408.4.1 Inside Dimensions.
EXCEPTION:
408.4.2 Floor Surfaces.
408.4.3 Platform to Hoistway Clearance.
408.4.4 Leveling.
408.4.5 Illumination.
408.4.6 Elevator Car Controls.
408.4.7 Designations and Indicators of Car Controls
408.4.8 Emergency Communications.
409 Private Residence Elevators 409.1 General.
EXCEPTION:
409.2 Call Controls.
409.3 Doors and Gates.
EXCEPTION:
409.3.1 Power Operation.
EXCEPTION:
409.3.2 Duration.
409.3.3 Door or Gate Location and Width.
409.4 Elevator Car Requirements.
847 409.4.1 Inside Dimensions.
409.4.2 Floor Surfaces.
409.4.3 Platform to Hoistway Clearance.
409.4.4 Leveling.
409.4.5 Illumination.
409.4.6 Elevator Car Controls.
409.4.6.1 Buttons.
409.4.6.2 Height.
409.4.6.3 Location.
409.4.7 Emergency Communications.
409.4.7.1 Type.
409.4.7.2 Operable Parts.
409.4.7.3 Compartment.
409.4.7.4 Cord.
410 Platform Lifts 410.1 General.
410.2 Lift Entry.
410.2.1 Doors and Gates.
EXCEPTIONS:
410.2.2 Ramps.
410.3 Floor Surfaces.
410.4 Platform to Runway Clearance.
410.5 Clear Floor Space.
410.5.1 Lifts with Single Door or Doors on Opposite Ends.
848 410.5.2 Lifts with Doors on Adjacent Sides.
EXCEPTION:
410.6 Operable Parts.
849 501 General 501.1 Scope.
502 Parking Spaces 502.1 General.
502.2 Vehicle Space Size.
EXCEPTION:
502.3 Vehicle Space Marking.
EXCEPTION:
502.4 Access Aisle.
502.4.1 Location.
502.4.2 Width.
502.4.3 Length.
502.4.4 Marking.
850 EXCEPTION:
502.5 Floor Surfaces.
502.6 Vertical Clearance.
502.7 Identification.
502.8 Relationship to Accessible Routes.
503 Passenger Loading Zones 503.1 General.
503.2 Vehicle Pull-up Space Size.
503.3 Access Aisle.
503.3.1 Location.
503.3.2 Width.
503.3.3 Length.
503.3.4 Marking.
503.4 Floor Surfaces.
503.5 Vertical Clearance.
504 Stairways 504.1 General.
504.2 Treads and Risers.
504.3 Open Risers.
851 504.4 Tread Surface.
504.5 Nosings.
504.5.1 Visual contrast.
504.6 Handrails.
504.7 Wet Conditions.
504.8 Lighting.
504.8.1 Illumination Level.
504.8.2 Lighting Controls.
504.9 Stair Level Identification.
505 Handrails 505.1 General.
852 505.2 Location.
EXCEPTIONS:
505.3 Continuity.
EXCEPTION:
505.4 Height.
505.5 Clearance.
505.6 Gripping Surface.
EXCEPTIONS:
505.7 Cross Section.
505.7.1 Circular Cross Section.
505.7.2 Noncircular Cross Sections.
505.8 Surfaces.
505.9 Fittings.
505.10 Handrail Extensions.
EXCEPTIONS:
853 505.10.1 Top and Bottom Extension at Ramps.
505.10.2 Top Extension at Stairs.
854 505.10.3 Bottom Extension at Stairs.
506 Windows 506.1 General.
855 601 General 601.1 Scope.
602 Drinking Fountains 602.1 General.
602.2 Clear Floor Space.
EXCEPTIONS:
602.3 Operable Parts.
602.4 Spout Outlet Height.
602.5 Spout Location.
856 602.6 Water Flow.
603 Toilet and Bathing Rooms 603.1 General.
603.2 Clearances. 603.2.1 Turning Space.
603.2.2 Door Swing.
EXCEPTIONS:
603.3 Mirrors.
EXCEPTION:
603.4 Coat Hooks and Shelves.
603.5 Diaper Changing Tables.
603.6 Operable Parts.
604 Water Closets and Toilet Compartments 604.1 General.
EXCEPTION:
604.2 Location.
Maximum Reach Depth
Maximum Reach Height
857 604.3 Clearance. 604.3.1 Clearance width.
604.3.2 Clearance Depth.
604.3.3 Clearance Overlap.
604.4 Height.
EXCEPTION:
604.5 Grab Bars.
EXCEPTIONS:
604.5.1 Fixed Side Wall Grab Bars.
858 EXCEPTION:
604.5.2 Rear Wall Grab Bars.
EXCEPTIONS:
604.6 Flush Controls.
EXCEPTION:
604.7 Dispensers.
604.8 Coat Hooks and Shelves.
604.9 Wheelchair Accessible Compartments. 604.9.1 General.
604.9.2 Size.
604.9.2.1 Minimum area.
604.9.2.2 Compartment for children’s use.
604.9.3 Doors.
604.9.3.1 Door Opening Location.
604.9.4 Approach.
861 604.9.5 Toe Clearance.
604.9.5.1 Toe Clearance at Compartments.
EXCEPTIONS:
604.9.5.2 Toe Clearance at Compartments for Children’s Use.
862 EXCEPTIONS:
604.9.6 Grab Bars.
604.10 Ambulatory Accessible Compartments. 604.10.1 General.
604.10.2 Size.
604.10.3 Doors.
604.10.4 Grab Bars.
604.11 Water Closets and Toilet Compartments for Children’s Use. 604.11.1 General.
604.11.2 Location.
604.11.3 Clearance.
604.11.4 Height.
863 604.11.5 Grab Bars.
604.11.6 Flush Controls.
EXCEPTION:
604.11.7 Dispensers.
604.11.8 Toilet Compartments.
605 Urinals 605.1 General.
605.2 Height and Depth.
605.3 Clear Floor Space.
605.4 Flush Controls.
606 Lavatories and Sinks 606.1 General.
606.2 Clear Floor Space.
EXCEPTIONS:
864 606.3 Height.
EXCEPTION:
606.4 Faucets.
606.5 Lavatories with Enhanced Reach Range.
606.6 Exposed Pipes and Surfaces.
607 Bathtubs 607.1 General.
607.2 Clearance.
607.3 Seat.
607.4 Grab Bars.
EXCEPTION:
607.4.1 Bathtubs with Permanent Seats.
865 607.4.1.1 Back Wall.
607.4.1.2 Control End Wall.
EXCEPTION:
607.4.1.2.1 Horizontal Grab Bar.
607.4.1.2.2 Vertical Grab Bar.
607.4.2 Bathtubs without Permanent Seats.
607.4.2.1 Back Wall.
607.4.2.2 Control End Wall.
607.4.2.3 Head End Wall.
607.5 Controls.
607.6 Hand Shower.
607.7 Bathtub Enclosures.
866 607.8 Water Temperature.
608 Shower Compartments 608.1 General.
608.2 Size, clearance and seat.
608.2.1 Transfer-type Shower Compartments.
608.2.1.1 Size.
608.2.1.2 Clearance.
608.2.1.3 Seat.
Exception:
608.2.2 Standard Roll-in-type Shower Compartments
608.2.2.1 Size.
608.2.2.2 Clearance.
EXCEPTION:
608.2.2.3 Seat.
EXCEPTIONS:
608.2.3 Alternate Roll-in-type Shower Compartments
867 608.2.3.1 Size.
608.2.3.2 Seat.
EXCEPTION:
608.3 Grab Bars.
EXCEPTION:
608.3.1 Transfer-Type Showers.
608.3.1.1 Horizontal Grab Bars.
608.3.1.2 Vertical Grab Bar.
868 608.3.2 Standard Roll-in-Type Showers.
608.3.3 Alternate Roll-in-Type Showers.
608.4 Controls and Hand Showers.
608.4.1 Transfer-Type Showers.
608.4.2 Standard Roll-in Showers.
869 608.4.3 Alternate Roll-in Showers.
608.5 Hand Showers.
EXCEPTION:
608.6 Thresholds.
EXCEPTION:
870 608.7 Shower Enclosures.
608.8 Water Temperature.
609 Grab Bars 609.1 General.
609.2 Cross Section.
609.2.1 Circular Cross Section.
609.2.2 Noncircular Cross Section.
609.3 Spacing.
EXCEPTIONS:
609.4 Position of Grab Bars. 609.4.1 General.
609.4.2 Position of Children’s Grab Bars.
609.5 Surface Hazards.
609.6 Fittings.
609.7 Installation and Configuration.
871 609.8 Structural Strength.
610 Seats 610.1 General.
610.2 Bathtub Seats.
610.3 Shower Compartment Seats.
872 610.3.1 Rectangular Seats.
610.3.2 L-Shaped Seats.
610.4 Structural Strength.
611 Washing Machines and Clothes Dryers 611.1 General.
611.2 Clear Floor Space.
611.3 Operable Parts.
611.4 Height.
612 Saunas and Steam Rooms 612.1 General.
612.2 Bench.
612.3 Turning space.
875 701 General 701.1 Scope.
702 Alarms 702.1 General.
703 Signs 703.1 General.
703.1.1 Designations.
EXCEPTION:
703.1.2 Directional and Informational Signs.
703.1.3 Pictograms.
EXCEPTION:
703.2 Visual Characters. 703.2.1 General.
EXCEPTION:
703.2.2 Case.
703.2.3 Style.
703.2.4 Character Height.
876 EXCEPTION:
703.2.5 Character Width.
703.2.6 Stroke Width.
703.2.7 Character Spacing.
703.2.8 Line Spacing.
EXCEPTION:
703.2.9 Height Above Floor.
EXCEPTION:
703.2.10 Finish and Contrast.
703.3 Raised Characters. 703.3.1 General.
703.3.2 Depth.
703.3.3 Case.
703.3.4 Style.
703.3.5 Character Height.
EXCEPTION:
703.3.6 Character Width.
703.3.7 Stroke Width.
703.3.7.1 Maximum.
703.3.7.2 Minimum.
703.3.8 Character Spacing.
877 703.3.9 Line Spacing.
703.3.10 Height above Floor.
EXCEPTION:
703.3.11 Location.
878 EXCEPTION:
703.3.12 Finish and Contrast.
EXCEPTION:
703.4 Braille 703.4.1 General.
703.4.2 Uppercase Letters.
703.4.3 Dimensions.
703.4.4 Position.
703.4.5 Mounting Height.
EXCEPTION:
879 703.5 Pictograms. 703.5.1 General.
703.5.2 Pictogram Field.
703.5.3 Finish and Contrast.
703.6 Symbols of Accessibility. 703.6.1 General.
703.6.2 Finish and Contrast.
703.6.3 Symbols.
880 703.6.3.1 International Symbol of Accessibility.
703.6.3.2 International Symbol of TTY.
703.6.3.3 Assistive Listening Systems.
703.6.3.4 Volume-Controlled Telephones.
703.7 Variable Message Signs. 703.7.1 General.
EXCEPTION:
703.7.2 Case.
703.7.3 Style.
703.7.4 Character Height.
EXCEPTION:
881 703.7.5 Character Width.
703.7.6 Stroke Width.
703.7.7 Character Spacing.
703.7.8 Line Spacing.
703.7.9 Height Above Floor.
703.7.10 Finish.
703.7.11 Contrast.
703.7.12 Protective Covering.
703.7.13 Brightness.
703.7.14 Rate of Change.
882 703.8 Remote Infrared Audible Sign (RIAS) Systems 703.8.1 General.
703.8.2 Transmitters.
703.8.3 Infrared Audible Sign Receivers. 703.8.3.1 Frequency.
703.8.3.2 Optical Power Density.
703.8.3.3 Audio Output.
703.8.3.4 Reception Range.
703.8.3.5 Multiple Signals.
703.9 Pedestrian Signals.
EXCEPTION:
704 Telephones. 704.1 General.
704.2 Wheelchair Accessible Telephones.
EXCEPTION:
704.2.1 Clear Floor Space.
704.2.1.1 Parallel Approach.
704.2.1.2 Forward Approach.
704.2.2 Operable Parts.
704.2.3 Telephone Directories.
704.2.4 Cord Length.
883 704.2.5 Hearing-Aid Compatibility.
704.3 Volume-control Telephones.
704.4 TTY.
704.5 Height.
EXCEPTION:
704.6 TTY Shelf.
704.7 Protruding Objects.
705 Detectable Warnings 705.1 General.
705.2 Standardization.
EXCEPTION:
705.3 Contrast.
705.4 Interior Locations.
705.5 Truncated Domes.
705.5.1 Size.
705.5.2 Height.
705.5.3 Spacing.
705.5.4 Alignment.
705.6 Transportation Platform Edges.
706 Assistive Listening Systems 706.1 General.
884 706.2 Receiver Jacks.
706.3 Receiver Hearing-aid Compatibility.
706.4 Sound Pressure Level.
706.5 Signal-to-noise Ratio.
706.6 Peak Clipping Level.
707 Automatic Teller Machines (ATMs) and Fare Machines 707.1 General.
707.2 Clear Floor Space.
EXCEPTION:
707.3 Operable Parts.
EXCEPTION:
885 707.4 Privacy.
707.5 Numeric Keys.
707.6 Function Keys.
707.6.1 Raised Symbols.
707.6.2 Contrast.
EXCEPTION:
707.7 Display Screen.
707.7.1 Visibility.
EXCEPTION:
707.7.2 Characters.
707.8 Speech Output.
EXCEPTIONS:
707.8.1 User Control.
EXCEPTION:
707.8.2 Receipts.
EXCEPTIONS:
707.9 Input Controls.
707.10 Braille Instructions.
708 Two-way Communication Systems 708.1 General.
886 708.2 Audible and Visual Indicators.
708.3 Handsets.
708.4 Telephone entry systems.
887 801 General 801.1 Scope.
802 Assembly Areas 802.1 General.
802.2 Floor Surfaces.
802.3 Width.
802.4 Depth.
888 802.5 Approach.
802.5.1 Overlap.
802.6 Integration of Wheelchair Space Locations.
802.7 Companion Seat.
802.7.1 Companion Seat Type.
802.7.2 Companion Seat Alignment.
802.8 Designated Aisle Seats.
802.8.1 Armrests.
802.8.2 Identification.
802.9 Lines of Sight.
802.9.1 Line of Sight over Seated Spectators.
802.9.1.1 Lines of Sight over Heads.
802.9.1.2 Lines of Sight between Heads.
802.9.2 Line of Sight over Standing Spectators.
802.9.2.1 Distance from Adjacent Seating.
889 802.9.2.2 Height.
802.10 Wheelchair Space Dispersion.
802.10.1 Horizontal Dispersion.
EXCEPTION:
890 802.10.2 Dispersion for Variety of Distances from the Event.
EXCEPTIONS:
802.10.3 Dispersion by Type.
802.10.4 Spaces Utilized Primarily for Viewing Motion Picture Projections.
802.10.4.1 Spaces with Seating on Risers.
891 802.10.4.2 Distance from the Screen.
803 Dressing, Fitting, and Locker Rooms 803.1 General.
803.2 Turning Space.
803.3 Door Swing.
803.4 Benches.
803.5 Coat Hooks and Shelves.
804 Kitchens and Kitchenettes 804.1 General.
804.2 Clearance.
EXCEPTION:
804.2.1 Pass-through Kitchens.
804.2.2 U-Shaped Kitchens.
804.3 Work Surface.
EXCEPTION:
804.4 Sinks.
892 804.5 Appliances.
804.5.1 Clear Floor Space.
804.5.2 Operable Parts.
EXCEPTIONS:
804.5.3 Dishwasher.
804.5.4 Cooktop.
804.5.4.1 Approach.
804.5.4.2 Forward approach.
804.5.4.3 Parallel approach.
804.5.4.4 Controls.
804.5.5 Oven.
804.5.5.1 Clear floor space.
804.5.5.2 Side-Hinged Door Ovens.
804.5.5.3 Bottom-Hinged Door Ovens.
804.5.5.4 Controls.
804.5.6 Refrigerator/Freezer.
893 805 Transportation Facilities 805.1 General.
805.2 Bus Boarding and Alighting Areas.
805.2.1 Surface.
805.2.2 Dimensions.
805.2.3 Slope.
805.2.4 Connection.
805.3 Bus Shelters.
805.4 Bus Signs.
EXCEPTION:
805.5 Rail Platforms.
805.5.1 Slope.
EXCEPTION:
805.5.2 Detectable Warnings.
805.6 Rail Station Signs.
EXCEPTION:
894 805.6.1 Entrances.
805.6.2 Routes and Destinations.
EXCEPTION:
805.6.3 Station Names.
805.7 Public Address Systems.
805.8 Clocks.
805.9 Escalators.
EXCEPTION:
805.10 Track Crossings.
895 EXCEPTION:
806 Holding Cells and Housing Cells 806.1 General.
806.2 Features for People Using Wheelchairs or Other Mobility Aids.
806.2.1 Turning Space.
806.2.2 Benches.
806.2.3 Beds.
806.2.4 Toilet and Bathing Facilities.
806.3 Communication Features.
806.3.1 Alarms.
EXCEPTION:
806.3.2 Telephones.
807 Courtrooms 807.1 General.
807.2 Turning Space.
EXCEPTION:
807.3 Clear Floor Space.
EXCEPTION:
807.4 Courtroom Stations.
807.5 Gallery seating.
897 901 General 901.1 Scope.
902 Dining Surfaces and Work Surfaces 902.1 General.
EXCEPTION:
902.2 Clear Floor Space.
EXCEPTIONS:
902.3 Exposed Surfaces.
902.4 Height.
902.5 Dining Surfaces and Work Surfaces for Children’s Use.
EXCEPTION:
902.5.1 Clear Floor Space.
EXCEPTION:
902.5.2 Height.
903 Benches 903.1 General.
903.2 Clear Floor Space.
903.3 Size.
903.4 Back Support.
903.5 Height.
EXCEPTION:
903.6 Structural Strength.
903.7 Wet Locations.
904 Sales and Service Counters 904.1 General.
EXCEPTION:
904.2 Approach.
904.3 Sales and Service Counters.
904.3.1 Parallel Approach.
898 904.3.2 Forward Approach.
904.4 Checkout Aisles.
904.4.1 Aisle.
904.4.2 Counters.
899 904.4.3 Check Writing Surfaces.
904.5 Food Service Lines.
904.5.1 Self-Service Shelves and Dispensing Devices.
904.5.2 Tray Slides.
904.6 Security Glazing.
905 Storage Facilities 905.1 General.
905.2 Clear Floor Space.
905.3 Height.
905.4 Operable Parts.
901 1001 General 1001.1 Scoping.
1002 Accessible Units 1002.1 General.
1002.2 Primary Entrance.
1002.3 Accessible Route.
1002.3.1 Location.
EXCEPTION:
1002.3.2 Turning Space.
EXCEPTIONS:
1002.3.3 Components.
1002.4 Walking Surfaces.
1002.5 Doors and Doorways.
EXCEPTIONS:
1002.6 Ramps.
1002.7 Elevators.
1002.8 Platform Lifts.
1002.9 Operable Parts.
EXCEPTIONS:
1002.10 Laundry Equipment.
1002.11 Toilet and Bathing Facilities.
902 1002.11.1 Grab Bars and Shower Seat Reinforcement
EXCEPTION:
1002.11.2 Accessible Toilet and Bathing Facility.
1002.11.2.1 Vanity Counter Top Space.
1002.11.2.2 Mirrors.
1002.12 Kitchens
EXCEPTION:
1002.13 Windows.
1002.13.1 Natural ventilation.
1002.13.2 Emergency escape.
1002.14 Storage Facilities.
EXCEPTION:
1002.15 Beds.
1002.15.1 Clear Floor Space.
EXCEPTION:
1002.15.2 Bed Frames.
1003 Type A Units 1003.1 General.
1003.2 Primary Entrance.
1003.3 Accessible Route.
1003.3.1 Location.
EXCEPTION:
1003.3.2 Turning Space.
EXCEPTIONS:
1003.3.3 Components.
1003.4 Walking Surfaces.
1003.5 Doors and Doorways.
EXCEPTIONS:
903 1003.6 Ramps.
1003.7 Elevators.
1003.8 Platform Lifts.
1003.9 Operable Parts.
EXCEPTIONS:
1003.10 Laundry Equipment.
1003.11 Toilet and Bathing Facilities.
1003.11.1 Grab Bar and Shower Seat Reinforcement
EXCEPTIONS:
1003.11.2 General.
1003.11.2.1 Doors.
EXCEPTION:
1003.11.2.2 Lavatory.
EXCEPTION:
1003.11.2.3 Mirrors.
1003.11.2.4 Water Closet.
1003.11.2.4.1 Location.
904 1003.11.2.4.2 Clearance Width.
1003.11.2.4.3 Clearance Depth.
1003.11.2.4.4 Clearance Overlap.
EXCEPTION:
1003.11.2.4.5 Height.
1003.11.2.4.6 Flush Controls.
1003.11.2.5 Bathing Fixtures.
905 1003.11.2.5.1 Bathtub.
EXCEPTIONS:
1003.11.2.5.2 Shower.
EXCEPTION:
906 1003.12 Kitchens and kitchenettes.
1003.12.1 Clearance.
1003.12.1.1 Minimum Clearance.
1003.12.1.2 U-Shaped Kitchens.
1003.12.2 Clear Floor Space.
1003.12.3 Work Surface.
1003.12.3.1 Clear Floor Space.
EXCEPTION:
1003.12.3.2 Height.
EXCEPTION:
1003.12.3.3 Exposed Surfaces.
907 1003.12.4 Sink.
1003.12.4.1 Clear Floor Space.
EXCEPTIONS:
1003.12.4.2 Height.
EXCEPTION:
1003.12.4.3 Faucets.
1003.12.4.4 Exposed Pipes and Surfaces.
1003.12.5 Appliances.
1003.12.5.1 Operable Parts.
EXCEPTIONS:
1003.12.5.2 Clear Floor Space.
908 1003.12.5.3 Dishwasher.
1003.12.5.4 Cooktop.
1003.12.5.4.1 Approach.
1003.12.5.4.2 Forward approach.
1003.12.5.4.3 Parallel approach.
1003.12.5.4.4 Controls.
1003.12.5.5 Oven.
1003.12.5.5.1 Clear floor space.
1003.12.5.5.2 Side-Hinged Door Ovens.
1003.12.5.5.3 Bottom-Hinged Door Ovens.
1003.12.5.5.4 Controls.
1003.12.5.6 Refrigerator/Freezer.
1003.13 Windows.
1003.13.1 Natural ventilation.
1003.13.2 Emergency escape.
1003.14 Storage Facilities.
EXCEPTION:
1004 Type B Units 1004.1 General.
1004.2 Primary Entrance.
1004.3 Accessible Route.
1004.3.1 Location.
EXCEPTIONS:
1004.3.2 Components.
1004.4 Walking Surfaces.
1004.4.1 Clear Width.
1004.4.2 Changes in Level.
EXCEPTION:
909 1004.5 Doors and Doorways.
1004.5.1 Primary Entrance Door.
EXCEPTION:
1004.5.2 User Passage Doorways.
1004.5.2.1 Clear Width.
1004.5.2.1.1 Double Leaf Doorways.
1004.5.2.2 Thresholds.
EXCEPTION:
1004.5.2.3 Automatic Doors.
1004.6 Ramps.
1004.7 Elevators.
1004.8 Platform Lifts.
1004.9 Operable Parts.
EXCEPTIONS:
1004.10 Laundry Equipment.
1004.10.1 Clear Floor Space.
1004.11 Toilet and Bathing Facilities.
EXCEPTION:
1004.11.1 Grab Bar and Shower Seat Reinforcement
EXCEPTIONS:
910 1004.11.1.1 Swing–up Grab Bars.
EXCEPTION:
1004.11.2 Clear Floor Space.
1004.11.2.1 Doors.
EXCEPTION:
1004.11.2.2 Knee and Toe Clearance.
1004.11.3 Toilet and Bathing Areas.
1004.11.3.1 Option A.
EXCEPTIONS:
1004.11.3.1.1 Lavatory.
EXCEPTION:
911 1004.11.3.1.2 Water Closet.
1004.11.3.1.2.1 Location.
1004.11.3.1.2.2 Clearance.
EXCEPTION:
1004.11.3.1.2.2.1 Clearance Width.
1004.11.3.1.2.2.2 Clearance Depth.
1004.11.3.1.2.2.3 Increased Clearance Depth at Forward Approach.
1004.11.3.1.2.2.4 Clearance Overlap.
1004.11.3.1.3 Bathing Fixtures.
1004.11.3.1.3.1 Parallel Approach Bathtubs
1004.11.3.1.3.2 Forward Approach Bathtubs
1004.11.3.1.3.3 Shower Compartment.
1004.11.3.2 Option B.
913 1004.11.3.2.1 Lavatory.
1004.11.3.2.1.1 Height.
1004.11.3.2.2 Water Closet.
1004.11.3.2.3 Bathing Fixtures.
1004.11.3.2.3.1 Bathtub.
1004.11.3.2.3.2 Shower Compartment.
1004.12 Kitchens and kitchenettes.
1004.12.1 Clearance.
914 1004.12.1.1 Minimum Clearance.
1004.12.1.2 U-Shaped Kitchens.
1004.12.2 Clear Floor Space.
1004.12.2.1 Sink.
EXCEPTION:
1004.12.2.2 Dishwasher.
915 1004.12.2.3 Cooktop.
1004.12.2.3.1 Approach.
1004.12.2.3.2 Forward approach.
1004.12.2.3.3 Parallel approach.
1004.12.2.4 Oven.
1004.12.2.5 Refrigerator/Freezer.
1004.12.2.6 Trash Compactor.
1005 Type C (Visitable) Units 1005.1 General.
1005.2 Unit Entrance.
1005.3 Connected Spaces.
1005.4 Interior Spaces.
Exception:
1005.5 Circulation Path.
1005.5.1 Components.
1005.5.2 Walking Surfaces.
1005.5.2.1 Clear Width.
1005.5.3 Doors and Doorways.
1005.5.3.1 Clear Width.
1005.5.3.2 Thresholds.
Exception:
1005.5.4 Ramps.
Exception:
1005.5.4.1 Clear Width.
1005.6 Toilet Room or Bathroom.
1005.7 Food Preparation Area.
Exception:
1005.8 Lighting Controls and Receptacle Outlets.
Exception:
916 1006 Units with Accessible Communication Features 1006.1 General.
1006.2 Unit Smoke Detection.
1006.3 Building Fire Alarm System.
1006.4 Visible Notification Appliances.
1006.4.1 Appliances.
1006.4.2 Activation.
1006.4.3 Interconnection.
1006.4.4 Prohibited Use.
1006.5 Unit Primary Entrance.
1006.5.1 Notification.
1006.5.2 Identification.
1006.6 Site, Building, or Floor Entrance.
1006.6.1 Public or Common-Use Interface.
1006.6.2 Unit Interface.
1006.7 Closed-Circuit Communication Systems.
917 1101 General 1101.1 Scope.
1101.2 Special Provisions. 1101.2 .1 General Exceptions.
1101.2.2 Area of Sport Activity.
1101.2.3 Recreational Boating Facilities.
1101.2.4 Exercise Machines and Equipment.
1101.3 Protruding Objects.
EXCEPTIONS:
1102 Amusement Rides. 1102.1 General.
1102.2 Accessible Routes.
EXCEPTIONS:
1102.3 Load and Unload Areas.
1102.4 Wheelchair Spaces in Amusement Rides.
1102.4.1 Floor Surface.
1102.4.2 Slope.
1102.4.3 Gaps.
EXCEPTION:
1102.4.4 Clearances.
EXCEPTIONS:
918 1102.4.4.1 Width and Length.
1102.4.4.2 Side Entry.
1102.4.4.3 Permitted Protrusions in Wheelchair Spaces.
1102.4.5 Ride Entry.
1102.4.6 Approach.
1102.4.7 Companion Seats.
1102.4.7.1 Shoulder-to-Shoulder Seating.
EXCEPTION:
1102.5 Amusement Ride Seats Designed for Transfer
1102.5.1 Clear Floor Space.
1102.5.2 Transfer Height.
1102.5.3 Transfer Entry.
1102.5.4 Wheelchair Storage Space.
1102.6 Transfer Devices for Use with Amusement Rides.
1102.6.1 Clear Floor Space.
1102.6.2 Transfer Height.
1102.6.3 Wheelchair Storage Space.
1103 Recreational Boating Facilities 1103.1 General.
1103.2 Accessible Routes.
920 1103.2.1 Boat Slips.
EXCEPTIONS:
1103.2.2 Boarding Piers at Boat Launch Ramps.
EXCEPTIONS:
1103.3 Clearances.
1103.3.1 Boat Slip Clearance.
EXCEPTIONS:
1103.3.2 Boarding Pier Clearances.
EXCEPTIONS:
921 1104 Exercise Machines and Equipment 1104.1 Clear Floor Space.
1105 Fishing Piers and Platforms 1105.1 Accessible Routes.
EXCEPTIONS:
922 1105.2 Railings.
1105.2.1 Height.
EXCEPTION:
1105.2.1.1 Dispersion.
1105.3 Edge Protection.
1105.3.1 Curb or Barrier.
1105.3.2 Extended Ground or Deck Surface.
1105.4 Clear Floor Space.
1105.5 Turning Space.
923 1106 Golf Facilities 1106.1 General.
1106.2 Accessible Routes.
EXCEPTION:
1106.3 Golf Car Passages.
1106.3.1 Clear Width.
1106.3.2 Barriers.
1106.4 Weather Shelters.
1107 Miniature Golf Facilities 1107.1 General.
1107.2 Accessible Routes.
EXCEPTION:
1107.3 Miniature Golf Holes.
1107.3.1 Start of Play.
1107.3.2 Golf Club Reach Range Area.
1108 Play Areas 1108.1 Scope.
1108.2 Accessible Routes for Play Areas.
1108.2.1 Ground Level and Elevated Play Components
1108.2.2 Soft Contained Play Structures.
1108.3 Age Groups.
EXCEPTIONS:
924 1108.3.1 Additions.
1108.3.2 Play Components.
1108.3.2.1 Ground Level Play Components.
1108.3.2.1.1 Minimum Number and Types.
1108.3.2.1.2 Additional Number and Types.
EXCEPTION:
1108.3.2.2 Elevated Play Components.
1108.4 Accessible Routes Within Play areas.
1108.4.1 Accessible Routes.
1108.4.1.1 Ground Level and Elevated Play Components.
EXCEPTIONS:
925 1108.4.1.2 Soft Contained Play Structures.
EXCEPTION:
1108.4.1.3 Water Play Components.
EXCEPTIONS:
1108.4.1.4 Clear Width.
1108.4.1.4.1 Ground Level.
EXCEPTIONS:
1108.4.1.4.2 Elevated.
EXCEPTIONS:
1108.4.1.5 Ramps.
1108.4.1.5.1 Ground Level.
926 1108.4.1.5.2 Elevated.
1108.4.1.5.3 Handrails.
EXCEPTIONS:
1108.4.1.5.3.1 Handrail Gripping Surfaces
1108.4.1.5.3.2 Handrail Height.
1108.4.1.6 Ground Surfaces.
1108.4.1.6.1 Surface Condition.
1108.4.1.6.2 Use Zones.
1108.4.2 Transfer Systems.
1108.4.2.1 Transfer Platforms.
1108.4.2.1.1 Size.
1108.4.2.1.2 Height.
1108.4.2.1.3 Transfer Space.
1108.4.2.1.4 Transfer Supports.
1108.4.2.2 Transfer Steps.
1108.4.2.2.1 Size.
1108.4.2.2.2 Height.
927 1108.4.2.2.3 Transfer Supports.
1108.4.3 Play Components.
1108.4.3.1 Turning Space.
1108.4.3.2 Clear Floor Space.
1108.4.3.3 Play Tables.
EXCEPTION:
1108.4.3.4 Entry Points and Seats.
EXCEPTION:
1108.4.3.5 Transfer Supports.
1109 Swimming Pools, Wading Pools, Hot tubs and Spas 1109.1 General.
1109.1.1 Swimming pools.
EXCEPTIONS:
1109.1.2 Wading pools.
928 1109.1.3 Hot tubs and Spas.
EXCEPTION:
1109.2 Pool Lifts.
1109.2.1 Pool Lift Location.
EXCEPTIONS:
1109.2.2 Seat Location.
1109.2.3 Clear Deck Space.
1109.2.4 Seat Height.
1109.2.5 Seat.
1109.2.6 Footrests and Armrests.
EXCEPTION:
1109.2.7 Operation.
929 1109.2.8 Submerged Depth.
1109.2.9 Lifting Capacity.
1109.3 Sloped Entries.
1109.3.1 Sloped Entry Route.
EXCEPTION:
1109.3.2 Submerged Depth.
1109.3.2.1 Swimming Pools.
1109.3.2.2 Wading Pools.
1109.3.3 Handrails.
EXCEPTIONS:
930 1109.4 Transfer Walls.
1109.4.1 Clear Deck Space.
1109.4.2 Height.
1109.4.3 Wall Depth and Length.
1109.4.4 Surface.
1109.4.5 Grab Bars.
1109.5 Transfer Systems.
1109.5.1 Transfer Platform.
931 1109.5.2 Transfer Space.
1109.5.3 Height.
1109.5.4 Transfer Steps.
1109.5.5 Surface.
1109.5.6 Size.
1109.5.7 Grab Bars.
932 1109.6 Pool Stairs.
1109.6.1 Pool Stairs.
EXCEPTION:
1109.6.2 Handrails.
1110 Shooting Facilities with Firing Positions 1110.1 Turning Space.
933 Accessible unit
937 and
947 Capital Development Board
PURPOSE
EFFECTIVE DATE
TYPOGRAPHIC CONVENTIONS
CHAPTER 5 GENERAL SITE AND BUILDING SECTION 502 PARKING SPACES
]]>
Chicago Building Code Title 14B – with April 2022 Supplement:2019 Edition ?u=/product/publishers/il/chicago-building-code-title-14b-with-april-2022-supplement/ Sun, 20 Oct 2024 04:19:51 +0000 Chicago Building Code Title 14B - with April 2022 Supplement
Published By Publication Date Number of Pages
IL 2019 71
]]>
PDF Catalog
PDF Pages PDF Title
1 2019 CHICAGO CONSTRUCTION CODES CHICAGO BUILDING CODE TITLE 14B
2 COPYRIGHT
3 COPYRIGHT FOR THE APRIL 2022 SUPPLEMENT
4 CITY OF CHICAGO OFFICE OF THE MAYOR MAYOR’S MESSAGE
5 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
6 ABOUT THE CHICAGO CONSTRUCTION CODES
10 ACKNOWLEDGMENTS
18 PREFACE TO THE MODEL CODE
20 EFFECTIVE USE OF THE CHICAGO BUILDING CODE
28 TABLE OF CONTENTS
34 TABLE OF SUPPLEMENTED PROVISIONS APRIL 2022
38 CHAPTER 1 SCOPE AND PURPOSE
SECTION 101 GENERAL
40 CHAPTER 2 DEFINITIONS AND MEASUREMENTS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
66 SECTION 203 MEASUREMENTS
68 APRIL 2022 SUPPLEMENT TO CHAPTER 2 DEFINITIONS AND MEASUREMENTS
69 SECTION 202 DEFINITIONS
SECTION 203 MEASUREMENTS
71 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
72 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
73 SECTION 306 FACTORY GROUP F
74 SECTION 307 HIGH-HAZARD GROUP H
TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
75 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
76 TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD
77 SECTION 308 INSTITUTIONAL GROUP I
79 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
80 SECTION 311 STORAGE GROUP S
81 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
83 APRIL 2022 SUPPLEMENT TO CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
84 SECTION 306 FACTORY GROUP F
SECTION 307 HIGH-HAZARD GROUP H
85 SECTION 308 INSTITUTIONAL GROUP I
SECTION 310 RESIDENTIAL GROUP R
SECTION 311 STORAGE GROUP S
86 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
88 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 [RESERVED]
SECTION 403 HIGH-RISE BUILDINGS
89 TABLE 403.2.4 MINIMUM BOND STRENGTH
91 SECTION 404 ATRIUMS
92 SECTION 405 UNDERGROUND BUILDINGS
93 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
95 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
96 SECTION 407 GROUP I-2
100 SECTION 408 GROUP I-3
102 SECTION 409 MOTION PICTURE PROJECTION ROOMS
103 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
105 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
107 TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTSa, b, c
108 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
SECTION 413 COMBUSTIBLE STORAGE
109 SECTION 414 [RESERVED]
SECTION 415 [RESERVED]
SECTION 416 [RESERVED]
SECTION 417 [RESERVED]
SECTION 418 [RESERVED]
SECTION 419 LIVE/WORK UNITS
110 SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
111 SECTION 421 [RESERVED]
112 SECTION 422 AMBULATORY CARE FACIILITIES
SECTION 423 [RESERVED]
SECTION 424 [RESERVED]
SECTION 425 [RESERVED]
SECTION 426 [RESERVED]
113 SECTION 427 [RESERVED]
SECTION 428 [RESERVED]
114 APRIL 2022 SUPPLEMENT TO CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
115 SECTION 403 HIGH-RISE BUILDINGS
SECTION 405 UNDERGROUND BUILDINGS
SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
118 TABLE 406.4.6 PUBLIC PARKING GARAGE HEIGHT (IN TIERS)
119 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
120 SECTION 414 HAZARDOUS MATERIALS
TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
SECTION 415 [RESERVED]
121 TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd, e, f
SECTION 417 [RESERVED]
SECTION 418 [RESERVED]
122 TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS I-1, R-1, R-2, R-3, R-4 AND R-5
123 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
124 TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANEa
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
125 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
126 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
127 SECTION 506 BUILDING AREA
128 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
129 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
130 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
EQUATION 5-1
EQUATION 5-2
131 EQUATION 5-3
EQUATION 5-4
EQUATION 5-5
SECTION 507 [RESERVED]
SECTION 508 MIXED USE AND OCCUPANCY
133 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)f
SECTION 509 INCIDENTAL USES
134 TABLE 509 INCIDENTAL USES
SECTION 510 [RESERVED]
135 APRIL 2022 SUPPLEMENT TO CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
136 SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANEa
137 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa, b
138 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa, b
139 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
SECTION 506 BUILDING AREA
EQUATION 5-4
EQUATION 5-5
140 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b
141 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b
142 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b
SECTION 508 MIXED USE AND OCCUPANCY
143 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)f
SECTION 509 INCIDENTAL USES
144 TABLE 509 INCIDENTAL USES
146 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
147 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
148 SECTION 604 COMBUSTIBLE MATERIAL IN TYPES III AND IV CONSTRUCTION
SECTION 605 BASEMENT CONSTRUCTION
150 APRIL 2022 SUPPLEMENT TO CHAPTER 6 TYPES OF CONSTRUCTION
151 SECTION 601 GENERAL
SECTION 602 CONSTRUCTION CLASSIFICATION
TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, d, g
SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
153 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
154 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
156 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
157 TABLE 705.2.1 PROJECTIONS FROM WALLS OF ANY TYPE OF CONSTRUCTION
EQUATION 7-2
158 TABLE 705.2.2 PROJECTIONS FROM WALLS OF TYPE III, IV OR V CONSTRUCTION
159 TABLE 705.8(1) MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
160 TABLE 705.8(2) MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION FOR PRIVATE GARAGES AND GROUP R-2, R-4 AND R-5 OCCUPANCIES UP TO 4 STORIES ABOVE GRADE PLANE
161 SECTION 706 FIRE WALLS
162 SECTION 707 FIRE BARRIERS
163 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIERS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
164 SECTION 708 FIRE PARTITIONS
165 SECTION 709 SMOKE BARRIERS
SECTION 710 [RESERVED]
SECTION 711 FLOOR AND ROOF ASSEMBLIES
166 SECTION 712 VERTICAL OPENINGS
168 SECTION 713 SHAFT ENCLOSURES
169 SECTION 714 PENETRATIONS
172 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
173 SECTION 716 OPENING PROTECTIVES
TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
174 TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
175 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
179 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
180 TABLE 717.3.2.1 FIRE DAMPER RATING
183 SECTION 718 CONCEALED SPACES
184 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
185 SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
186 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
SECTION 722 CALCULATED FIRE RESISTANCE
187 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
188 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
189 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
190 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
191 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
192 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
193 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
194 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
195 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
196 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
197 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
198 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
199 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
200 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
201 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
202 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
203 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
204 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
205 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
206 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
207 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
208 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
209 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
210 TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
EQUATION 7-4
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
211 FIGURE 722.2.1.3.1 CERRAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
212 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
213 FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFRFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
214 FIGURE 722.2.2.3 (1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS
215 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
216 TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
217 EQUATION 7-6
EQUATION 7-7
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
218 TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
219 EQUATION 7-9
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
220 EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
221 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
222 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
EQUATION 7-14
EQUATION 7-15
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
223 FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS a, b
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
224 EQUATION 7-16
EQUATION 7-17
FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
226 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
227 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
228 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
229 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
230 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
231 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
232 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
233 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
234 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
235 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa, b, c, d
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
236 TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
237 APRIL 2022 SUPPLEMENT TO CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
238 SECTION 705 EXTERIOR WALLS
TABLE 705.8(1) MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION FOR BUILDINGS NOT COVERED BY TABLE 705.8(2)
239 TABLE 705.8(2) MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION FOR PRIVATE GARAGES AND GROUP R-2, R-4 AND R-5 OCCUPANCIES UP TO 4 STORIES ABOVE GRADE PLANEa
240 SECTION 706 FIRE WALLS
241 SECTION 707 FIRE BARRIERS
SECTION 712 VERTICAL OPENINGS
SECTION 716 OPENING PROTECTIVES
SECTION 722 CALCULATED FIRE RESISTANCE
242 TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
243 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
244 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
246 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
247 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
248 SECTION 806 DECORATIVE MATERIALS AND TRIM
249 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
250 APRIL 2022 SUPPLEMENT TO CHAPTER 8 INTERIOR FINISHES
251 SECTION 803 WALL AND CEILING FINISHES
TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
252 SECTION 804 INTERIOR FLOOR FINISH
253 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
SECTION 902 FIRE PUMP AND RISER ROOM SIZE
254 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
256 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
258 TABLE 903.2.11.8 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
260 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
263 SECTION 905 STANDPIPE SYSTEMS
265 SECTION 906 PORTABLE FIRE EXTINGUISHERS
TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
266 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
273 TABLE 907.5.2.3.2 VISIBLE ALARMS
275 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
SECTION 910 SMOKE AND HEAT REMOVAL
276 EQUATION 9-3
EQUATION 9-4
SECTION 911 FIRE COMMAND CENTER
277 SECTION 912 FIRE DEPARTMENT CONNECTIONS
278 SECTION 913 FIRE PUMPS
279 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
280 SECTION 916 GAS DETECTION SYSTEMS
281 SECTION 917 [RESERVED]
SECTION 918 [RESERVED]
SECTION 919 CITY FIRE ALARM BOX
283 APRIL 2022 SUPPLEMENT TO CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
284 SECTION 901 GENERAL
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
285 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
SECTION 905 STANDPIPE SYSTEMS
286 SECTION 906 PORTABLE FIRE EXTINGUISHERS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
288 SECTION 908 [RESERVED]
SECTION 909 SMOKE CONTROL SYSTEMS
SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 915 CARBON MONOXIDE DETECTION
289 SECTION 916 GAS DETECTION SYSTEMS
290 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
291 SECTION 1004 OCCUPANT LOAD
292 TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
TABLE 1004.5—continued MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
293 SECTION 1005 MEANS OF EGRESS SIZING
294 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
295 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
296 TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2, R-3, R-4 and R-5 OCCUPANCIES
298 SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
299 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
302 SECTION 1010 DOORS, GATES AND TURNSTILES
303 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
304 TABLE 1010.1.4.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
310 SECTION 1011 STAIRWAYS
314 SECTION 1012 RAMPS
315 SECTION 1013 EXIT SIGNS
316 SECTION 1014 HANDRAILS
317 SECTION 1015 GUARDS
319 SECTION 1016 EXIT ACCESS
320 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
321 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
322 SECTION 1020 CORRIDORS
TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.2 MINIMUM CORRIDOR WIDTH
323 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
324 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
325 SECTION 1024 EXIT PASSAGEWAYS
326 SECTION 1025 [RESERVED]
SECTION 1026 HORIZONTAL EXITS
327 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
328 SECTION 1028 EXIT DISCHARGE
329 SECTION 1029 ASSEMBLY
333 TABLE 1029.13.2.1 OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
335 SECTION 1030 [RESERVED]
336 APRIL 2022 SUPPLEMENT TO CHAPTER 10 MEANS OF EGRESS
337 SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
SECTION 1004 OCCUPANT LOAD
TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
338 TABLE 1004.5—continued MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
339 SECTION 1005 MEANS OF EGRESS SIZING
SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
340 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
342 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
SECTION 1010 DOORS, GATES AND TURNSTILES
SECTION 1011 STAIRWAYS
TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
343 SECTION 1015 GUARDS
SECTION 1016 EXIT ACCESS
344 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
SECTION 1020 CORRIDORS
TABLE 1031.1 FRONTAGE REQUIREMENTS
345 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
SECTION 1026 HORIZONTAL EXITS
SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
346 SECTION 1028 EXIT DISCHARGE
347 SECTION 1029 ASSEMBLY
SECTION 1031 FRONTAGE AND FIRE DEPARTMENT ACCESS REQUIREMENTS FOR GROUP E-1
349 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
351 SECTION 1102 COMPLIANCE
SECTION 1103 SCOPING REQUIREMENTS
352 SECTION 1104 ACCESSIBLE ROUTE
353 SECTION 1105 ACCESSIBLE ENTRANCES
354 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.1 ACCESSIBLE PARKING SPACES
TABLE 1106.2 ACCESSIBLE PARKING SPACES FOR R-2, R-3, AND R-4 OCCUPANCIES
355 SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
357 TABLE 1107.6.1.1 ACCESSIBLE UNITS
361 SECTION 1108 SPECIAL OCCUPANCIES
TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
362 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
363 SECTION 1109 OTHER FEATURES AND FACILITIES
366 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
SECTION 1110 RECREATIONAL FACILITIES
368 TABLE 1110.4.9.1 BOAT SLIPS
369 SECTION 1111 SIGNAGE
371 APRIL 2022 SUPPLEMENT TO CHAPTER 11 ACCESSIBILITY
372 SECTION 1101 GENERAL
373 SECTION 1104 ACCESSIBLE ROUTE
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
374 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
375 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
376 SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
377 SECTION 1205 YARDS AND COURTS
378 SECTION 1206 [RESERVED]
SECTION 1207 INTERIOR SPACE DIMENSIONS
379 SECTION 1208 ACCESS TO UNOCCUPIED SPACES
SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
380 SECTION 1210 RODENT PROTECTION
382 APRIL 2022 SUPPLEMENT TO CHAPTER 12 INTERIOR ENVIRONMENT
383 SECTION 1202 VENTILATION
SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
384 SECTION 1205 YARDS AND COURTS
SECTION 1207 INTERIOR SPACE DIMENSIONS
385 SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
SECTION 1210 RODENT PROTECTION
SECTION 1211 INSECT SCREENS
386 SECTION 1212 RESIDENTIAL SECURITY DEVICES
387 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
389 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
390 SECTION 1403 MATERIALS
SECTION 1404 INSTALLATION OF WALL COVERINGS
391 TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
TABLE 1404.3.2 CLASS III VAPOR RETARDERS
394 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
395 TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
396 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
397 SECTION 1409 PLASTIC COMPOSITE DECKING
399 APRIL 2022 SUPPLEMENT TO CHAPTER 14 EXTERIOR WALLS
400 SECTION 1402 PERFORMANCE REQUIREMENTS
SECTION 1404 INSTALLATION OF WALL COVERINGS
SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
402 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
SECTION 1504 PERFORMANCE REQUIREMENTS
403 TABLE 1504.1.1 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACORDANCE WITH ASTM D316 OR D71581
404 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUC
405 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
406 TABLE 1507.1.1(1) UNDERLAYMENT TYPES
407 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
408 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
TABLE 1507.2.8.2 VALLEY LINING MATERIAL
409 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
410 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
412 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
413 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
414 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
415 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
416 SECTION 1508 ROOF INSULATION
417 [BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1510 ROOFTOP STRUCTURES
419 SECTION 1511 REROOFING
SECTION 1512 [RESERVED]
SECTION 1513 OCCUPIABLE ROOFTOPS
420 TABLE 1513.3.1 REQUIRED FIRE SEPARATION DISTANCE FOR OUTDOOR ELEMENTS OF OCCUPIABLE ROOFTOPS ON BUILDINGS UP TO 55 FEET IN BUILDING HEIGHT
SECTION 1514 VEGETATIVE ROOFS, ROOF GARDEN AND LANDSCAPED ROOFS
421 SECTION 1515 SOLAR REFLECTANCE
422 APRIL 2022 SUPPLEMENT TO CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
423 SECTION 1502 ROOF DRAINAGE
SECTION 1504 PERFORMANCE REQUIREMENTS
SECTION 1505 FIRE CLASSIFICATION
SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
424 SECTION 1510 UNOCCUPIED ROOFTOP STRUCTURES
SECTION 1513 OCCUPIABLE ROOFTOPS
425 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
426 SECTION 1604 GENERAL DESIGN REQUIREMENTS
427 TABLE 1604.3 DEFLECTION LIMITS
428 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
429 SECTION 1605 LOAD COMBINATIONS
EQUATION 16-1
EQUATION 16-2
430 EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
431 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
432 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
434 EQUATION 16-23
TABLE 1607.11.1 LIVE LOAD ELEMENT FACTOR, KLL
435 EQUATION 16-24
EQUATION 16-25
EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
437 SECTION 1608 SNOW LOADS
SECTION 1609 WIND LOADS
EQUATION 16-33
438 EQUATION 16-34
439 TABLE 1609.6.1 LOAD DUE TO WIND PRESSURE ON MAIN WINDFORCE-RESISTING SYSTEM
TABLE 1609.6.2 MULTIPLIERS TO DETERMINE COMPONENTS AND CLADDING WIND PRESSURE
440 SECTION 1610 SOIL LATERAL LOADS
TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1611 RAIN LOADS
SECTION 1612 FLOOD DESIGN
SECTION 1613 EARTHQUAKE LOADS
441 TABLE 1613.2.3 SEISMIC DESIGN PARAMETERS
442 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 [RESERVED]
SECTION 1616 STRUCTURAL INTEGRITY
443 EQUATION 16-40
EQUATION 16-41
444 FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
445 APRIL 2022 SUPPLEMENT TO CHAPTER 16 STRUCTURAL DESIGN
446 SECTION 1604 GENERAL DESIGN REQUIREMENTS
TABLE 1604.3 DEFLECTION LIMITSa, b, c, h, i
447 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
448 SECTION 1607 LIVE LOADS
TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
449 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
450 SECTION 1609 WIND LOADS
TABLE 1609.6.1 LOAD DUE TO WIND PRESSURE ON MAIN WINDFORCE-RESISTING SYSTEM
TABLE 1609.6.2 MULTIPLIERS TO DETERMINE COMPONENTS AND CLADDING WIND PRESSURE
SECTION 1611 RAIN LOADS
451 SECTION 1613 EARTHQUAKE LOADS
452 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 [RESERVED]
SECTION 1703 PRODUCTS, MATERIALS AND ASSEMBLIES
453 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
455 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
456 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
457 TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
458 TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
462 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
463 SECTION 1709 PRECONSTRUCTION LOAD TESTS
466 APRIL 2022 SUPPLEMENT TO CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
467 SECTION 1703 PRODUCTS, MATERIALS AND ASSEMBLIES
SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
469 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
471 SECTION 1804 EXCAVATION, GRADING AND FILL
472 SECTION 1805 DAMPPROOFING AND WATERPROOFING
473 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
474 TABLE 1806.2(1) PRESUMPTIVE LOAD-BEARING VALUES WITHOUT FULL GEOTECHNICAL INVESTIGATION
TABLE 1806.2(2) PRESUMPTIVE VERTICLE FOUNDATION PRESSURE VALUES WITH GEOTECHNICAL INVESTIGATION
475 TABLE 1806.2(2)—continued
TABLE 1806.2(3) STANDARDS FOR CLASSIFYING SOIL CONSISTENCY AND RELATIVE DENSITY
476 SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
477 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c
478 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b, c
TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHESa, b, c
479 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
480 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHES
481 EQUATION 18-1
EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
483 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH fC OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
SECTION 1809 SHALLOW FOUNDATIONS
484 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
485 SECTION 1810 DEEP FOUNDATIONS
488 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
TABLE 1810.3.3.1.2 MAXIUMUM AXIAL LOADS ALLOWED WITHOUT LOAD TEST
489 EQUATION 18-4
492 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
493 EQUATION 18-8
EQUATION 18-9
EQUATION 18-10
499 APRIL 2022 SUPPLEMENT TO CHAPTER 18 SOILS AND FOUNDATIONS
500 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
TABLE 1806.2(2) PRESUMPTIVE VERTICAL FOUNDATION PRESSURE VALUES WITH GEOTECHNICAL INVESTIGATION
501 TABLE 1806.2(2)—continued
TABLE 1806.2(3) STANDARDS FOR CLASSIFYING SOIL CONSISTENCY AND RELATIVE DENSITY
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
SECTION 1808 FOUNDATIONS
SECTION 1810 DEEP FOUNDATIONS
504 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
505 SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
507 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
508 SECTION 1908 SHOTCRETE
510 APRIL 2022 SUPPLEMENT TO CHAPTER 19 CONCRETE
511 SECTION 1907 MINIMUM SLAB PROVISIONS
513 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
515 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
SECTION 2103 MASONRY CONSTRUCTION MATERIALS
516 TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
517 SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 [RESERVED]
SECTION 2110 GLASS UNIT MASONRY
518 SECTION 2111 MASONRY FIREPLACES
520 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
SECTION 2112 MASONRY HEATERS
521 SECTION 2113 MASONRY CHIMNEYS
523 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
524 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
525 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114 DRY-STACK MASONRY
TABLE 2114.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
527 APRIL 2022 SUPPLEMENT TO CHAPTER 21 MASONRY
528 SECTION 2101 GENERAL
530 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
531 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
532 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
533 SECTION 2212 CAST IRON
534 APRIL 2022 SUPPLEMENT TO CHAPTER 22 STEEL
535 SECTION 2212 CAST IRON
537 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
541 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
542 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
543 TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
544 TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR) (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
545 TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood structural panels are five-ply, five-layer unless otherwise noted)a
TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKNESS
548 TABLE 2304.10.1 FASTENING SCHEDULE
549 TABLE 2304.10.1—continued FASTENING SCHEDULE
550 TABLE 2304.10.1—continued FASTENING SCHEDULE
551 TABLE 2304.10.1—continued FASTENING SCHEDULE
552 TABLE 2304.10.1—continued FASTENING SCHEDULE
TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
554 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)a, c
EQUATION 23-2
555 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
556 SECTION 2306 ALLOWABLE STRESS DESIGN
557 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
558 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
559 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
560 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
561 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
562 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
563 TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
565 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
566 TABLE 2308.4.1.1(1) —continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
567 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
TABLE 2308.4.2.1(1) [RESERVED]
568 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
569 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
570 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
571 FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
572 TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
573 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
574 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
575 TABLE 2308.6.1a WALL BRACING REQUIREMENTS
576 TABLE 2308.6.3(1) BRACING METHODS
577 TABLE 2308.6.3(1)—continued BRACING METHODS
TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
578 TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not exposed to the weather, strength axis parallel or perpendicular to studs except as Indicated)
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING (Not exposed to the weather, long dimension of the panel parallel or perpendicular to studs)
TABLE 2308.6.3(5) HARDBOARD SIDING
579 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
580 FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
582 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
584 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
586 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
587 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
588 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
589 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
590 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES
591 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
592 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
593 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
594 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
595 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
596 TABLE 2308.7.2(4) [RESERVED]
TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
597 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
598 TABLE 2308.7.2(6) [RESERVED]
TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSg
599 TABLE 2308.7.5 REQUIRED RATING OF UPLIFT CONNECTORS (pounds)a
600 TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
601 SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
603 APRIL 2022 SUPPLEMENT TO CHAPTER 23 WOOD
604 SECTION 2303 MINIMUM STANDARDS AND QUALITY
SECTION 2306 ALLOWABLE STRESS DESIGN
605 SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
606 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
607 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb and required number of jack studs)
608 TABLE 2308.6.1a WALL BRACING REQUIREMENTS
609 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with storage, live load = 20 psf, L/Δ = 240)
610 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with storage, live load = 20 psf, L/Δ = 240)
611 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ceiling not attached to rafters, L/Δ = 180)
612 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ceiling not attached to rafters, L/Δ = 180)
613 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ceiling attached to rafters, L/Δ = 240)
614 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ceiling attached to rafters, L/Δ = 240)
615 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSg
616 TABLE 2308.7.5 REQUIRED RATING OF UPLIFT CONNECTORS (pounds)a, b, c, e, f, g, h
618 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
619 EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
620 EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
621 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
622 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
623 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
TABLE 2407.1.1 MODULES OF RAPTURE
624 SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
626 APRIL 2022 SUPPLEMENT TO CHAPTER 24 GLASS AND GLAZING
627 SECTION 2402 [RESERVED]
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
629 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 [RESERVED]
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
630 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERI
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
631 TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
632 TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
633 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
634 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
635 SECTION 2514 REINFORCED GYPSUM CONCRETE
637 APRIL 2022 SUPPLEMENT TO CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
638 SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2511 INTERIOR PLASTER
640 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
644 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
645 TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2604 INTERIOR FINISH AND TRIM
646 TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2605 PLASTIC VENEER
647 SECTION 2606 LIGHT-TRANSMITTING PLASTICS
648 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELS
649 SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
650 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
651 SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
652 SECTION 2614 [RESERVED]
654 APRIL 2022 SUPPLEMENT TO CHAPTER 26 PLASTIC
655 SECTION 2603 FOAM PLASTIC INSULATION
SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
SECTION 2613 FIBER-REINFORCED POLYMER
657 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
659 APRIL 2022 SUPPLEMENT TO CHAPTER 27 ELECTRICAL
660 SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
662 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
664 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
666 APRIL 2022 SUPPLEMENT TO CHAPTER 29 PLUMBING SYSTEMS
669 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
670 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
SECTION 3005 MACHINE ROOMS
671 SECTION 3006 [RESERVED]
SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
672 SECTION 3008 [RESERVED]
673 APRIL 2022 SUPPLEMENT TO CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
674 SECTION 3002 HOISTWAY ENCLOSURES
676 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
677 SECTION 3103 TEMPORARY STRUCTURES
678 SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
679 SECTION 3105 AWNINGS AND CANOPIES
680 SECTION 3106 MARQUEES
SECTION 3107 [RESERVED]
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
681 SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3112 GREENHOUSES
682 SECTION 3113 [RESERVED]
SECTION 3114 FENCES
TABLE 3114.3 MAXIMUM HEIGHT OF FENCES
684 APRIL 2022 SUPPLEMENT TO CHAPTER 31 SPECIAL CONSTRUCTION
685 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3105 AWNINGS AND CANOPIES
SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
686 SECTION 3114 FENCES
687 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
689 APRIL 2022 SUPPLEMENT TO CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC WAY
690 SECTION 3202 ENCROACHMENTS
692 CHAPTER 33 WORK SITE SAFETY AND OPERATIONS
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
693 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
SECTION 3307 PROTECTION OF ADJOINING PROPERTY
694 SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
695 SECTION 3313 [RESERVED]
SECTION 3314 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
SECTION 3315 TEMPORARY HEATING EQUIPMENT
696 SECTION 3316 PRECAUTIONS AGAINST FIRE
SECTION 3317 FLAMMABLE AND COMBUSTIBLE LIQUIDS
697 SECTION 3318 FLAMMABLE GASES
SECTION 3319 EXPLOSIVE MATERIALS
SECTION 3320 FIRE REPORTING
SECTION 3321 MOTORIZED CONSTRUCTION EQUIPMENT
SECTION 3322 SAFEGUARDING ROOFING OPERATIONS
698 SECTION 3323 SCAFFOLDING
SECTION 3324 CONSTRUCTION SITE CLEANLINESS
700 APRIL 2022 SUPPLEMENT TO CHAPTER 33 WORK SITE SAFETY AND OPERATIONS
701 SECTION 3301 GENERAL
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3318 FLAMMABLE GASES
SECTION 3323 SCAFFOLDING
SECTION 3324 CONSTRUCTION SITE CLEANLINESS
703 CHAPTER 34 [RESERVED]
705 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
ACI
706 AISC
AISI
ANSI
707 APA
708 ASABE
ASCE/SEI
ASHRAE
709 ASME
ASSE
ASTM
720 AWC
AWCI
AWPA
721 AWS
BHMA
CEN
CPA
CPSC
722 CSA
CSSB
DASMA
DOC
DOL
723 DOTn
FM
GA
HPVA
724 ICC
ISO
NAAMM
NCMA
NFPA
727 PCI
RMI
SBCA
SDI
SJI
728 SPRI
SRCC
TIA
TMS
729 TPI
UL
731 ULC
USC
WCLIB
WDMA
733 APRIL 2022 SUPPLEMENT TO CHAPTER 35 REFERENCED STANDARDS
734 AFSI
ASABE
ICC
735 NFPA
TIA
UL
736 CHAPTER 36 APPENDICES
APPENDICES A THROUGH C [RESEREVED]
APPENDIX D FIRE LIMITS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
737 SECTION D103 CHANGES TO BUILDINGS AND STRUCTURES
SECTION D104 [RESERVED]
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE LIMITS
SECTION D106 [RESERVED]
738 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
SECTION E105 OTHER FEATURES AND FACILITIES
739 TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
SECTION E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
740 SECTION E107 SIGNAGE
SECTION E108 BUS STOPS
741 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
SECTION E110 AIRPORTS
742 SECTION E111 PUBLIC WAY
SECTION E112 REFERENCED STANDARDS
APPENDICES F THROUGH R [RESERVED]
APPENDIX S OPTIONAL SMOKE CONTROL SYSTEMS
SECTION S101 GENERAL
744 EQUATION S-1
745 EQUATION S-2
752 APRIL 2022 SUPPLEMENT TO CHAPTER 36 APPENDICES
753 APPENDIX D FIRE LIMITS
APPENDIX S OPTIONAL SMOKE CONTROL SYSTEMS
755 INDEX
791 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES ICC A117.1-2009
792 COPYRIGHT
793 AMERICAN NATIONAL STANDARD
795 FOREWORD
797 ACCREDITED STANDARD COMMITTEE A117 ON ARCHITECTURAL FEATURES AND SITE DESIGN OF PUBLIC BUILDINGS AND RESIDENTIAL STRUCTURES FOR PERSONS WITH DISABILITIES
800 INTEREST CATEGORIES
801 CONTENTS
805 LIST OF FIGURES
811 CHAPTER 1 APPLICATION AND ADMINISTRATION
101 PURPOSE
102 ANTHROPOMETRIC PROVISIONS
103 COMPLIANCE ALTERNATIVES
104 GENERAL
105 REFERENCED DOCUMENTS
812 FIGURE 104.3 GRAPHIC CONVENTION FOR FIGURES
813 106 DEFINITIONS
815 CHAPTER 2 SCOPING
201 GENERAL
202 DWELLING AND SLEEPING UNITS
203 ADMINISTRATION
817 CHAPTER 3 BUILDING BLOCKS
301 GENERAL
302 FLOOR SURFACES
FIGURE 302.2 CARPET ON FLOOR SURFACES
FIGURE 302.3 OPENINGS IN FLOOR SURFACES
303 CHANGES IN LEVEL
FIGURE 303.2 VERTICAL CHANGES IN LEVEL
FIGURE 303.3 BEVELED CHANGES IN LEVEL
304 TURNING SPACE
818 FIGURE 304.3 SIZE OF TURNING SPACE
305 CLEAR FLOOR SPACE
FIGURE 305.3 SIZE OF CLEAR FLOOR SPACE
819 FIGURE 305.5 POSITION OF CLEAR FLOOR SPACE
FIGURE 305.7 MANEUVERING CLEARANCE IN AN ALCOVE
306 KNEE AND TOE CLEARANCE
307 PROTRUDING OBJECTS
820 FIGURE 306.2 TOE CLEARANCE
FIGURE 306.3 KNEE CLEARANCE
821 FIGURE 307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 307.4 REDUCED VERTICAL CLEARANCE
308 REACH RANGES
FIGURE 308.2.1 UNOBSTRUCTED FORWARD REACH
822 FIGURE 307.3 POST-MOUNTED PROTRUDING OBJECTS
823 FIGURE 308.2.2 OBSTRUCTED HIGH FORWARD REACH
FIGURE 308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 308.3.2 OBSTRUCTED HIGH SIDE REACH
824 309 OPERABLE PARTS
825 CHAPTER 4 ACCESSIBLE ROUTES
401 GENERAL
402 ACCESSIBLE ROUTES
403 WALKING SURFACES
FIGURE 403.5 CLEAR WIDTH OF AN ACCESSIBLE ROUTE
404 DOORS AND DOORWAYS
826 FIGURE 403.5.1 CLEAR WIDTH AT 180º TURN
FIGURE 404.2.2 CLEAR WIDTH OF DOORWAYS
827 TABLE 404.2.3.2 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS
TABLE 404.2.3.3 MANEUVERING CLEARANCES AT SLIDING AND FOLDING DOORS
FIGURE 404.2.3.3 MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS
828 FIGURE 404.2.3.2 MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS
829 TABLE 404.2.3.4 MANEUVERING CLEARANCES FOR DOORWAYS WITHOUT DOORS
FIGURE 404.2.3.4 MANEUVERING CLEARANCE AT DOORWAYS WITHOUT DOORS
830 FIGURE 404.2.3.5 MANEUVERING CLEARANCE AT RECESSED DOORS
831 FIGURE 404.2.5 TWO DOORS IN A SERIES
832 405 RAMPS
TABLE 405.2— ALLOWABLE RAMP DIMENSIONS FOR CONSTRUCTION IN EXISTING SITES, BUILDINGS AND FACILITIES
FIGURE 405.7 RAMP LANDINGS
833 FIGURE 405.9 EDGE PROTECTION LIMITED DROP OFF
FIGURE 405.9.1 EXTENDED FLOOR SURFACE
834 FIGURE 405.9.2 RAMP EDGE PROTECTION
406 CURB RAMPS
FIGURE 406.2 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
FIGURE 406.3 SIDES OF CURB RAMPS
835 FIGURE 406.7 LANDINGS
FIGURE 406.10 DIAGONAL CURB RAMPS
836 FIGURE 406.11 ISLANDS
407 ELEVATORS
837 FIGURE 407.2.1.1 HEIGHT OF ELEVATOR CALL BUTTONS
FIGURE 407.2.1.7 DESTINATION-ORIENTED ELEVATOR INDICATION
838 FIGURE 407.2.2.2 ELEVATOR VISIBLE SIGNALS
839 FIGURE 407.2.3.1 FLOOR DESIGNATION
FIGURE 407.2.3.2 DESTINATION-ORIENTED ELEVATOR CAR IDENTIFICATION
840 TABLE 407.4.1—MINIMUM DIMENSIONS OF ELEVATOR CARS
FIGURE 407.4.6.2 ELEVATOR CAR CONTROL BUTTONS
841 FIGURE 407.4.1 INSIDE DIMENSIONS OF ELEVATOR CARS
842 408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS
843 TABLE 407.4.7.1.3—CONTROL BUTTON IDENTIFICATION
844 409 PRIVATE RESIDENCE ELEVATORS
845 FIGURE 408.3.3 DOOR LOCATION FOR LIMITED USE/LIMITED APPLICATION (LULA) ELEVATORS
846 FIGURE 408.4.1 INSIDE DIMENSIONS OF LIMITED USE/LIMITED APPLICATION (LULA) ELEVATOR CARS
847 FIGURE 409.4.6.3 LOCATION OF CONTROLS IN PRIVATE RESIDENCE ELEVATORS
410 PLATFORMS LIFTS
848 FIGURE 410.2.1 PLATFORM LIFT DOORS AND GATES
849 CHAPTER 5 GENERAL SITE AND BUILDING ELEMENTS
501 GENERAL
502 PARKING SPACES
FIGURE 502.2 VEHICLE PARKING SPACE SIZE
FIGURE 502.4 PARKING SPACE ACCESS AISLE
850 503 PASSENGER LOADING ZONES
FIGURE 503.3 PASSENGER LOADING ZONE ACCESS AISLE
504 STAIRWAYS
851 FIGURE 504.2 TREADS AND RISERS FOR ACCESSIBLE STAIRWAYS
FIGURE 504.5 STAIR NOSINGS
505 HANDRAILS
852 FIGURE 505.4 HANDRAIL HEIGHT
FIGURE 505.5 HANDRAIL CLEARANCE
853 FIGURE 505.7 HANDRAIL CROSS SECTION
FIGURE 505.10.1 TOP AND BOTTOM HANDRAIL EXTENSIONS AT RAMPS
FIGURE 505.10.2 TOP HANDRAIL EXTENSIONS AT STAIRS
854 FIGURE 505.10.3 BOTTOM HANDRAIL EXTENSIONS AT STAIRS
506 WINDOWS
855 CHAPTER 6 PLUMBING ELEMENTS AND FACILITIES
601 GENERAL
602 DRINKING FOUNTAINS
FIGURE 602.2 PARALLEL APPROACH AT DRINKING FOUNTAINS PRIMARILY FOR CHILDREN’S USE—(EXCEPTION 2)
FIGURE 602.5 DRINKING FOUNTAIN SPOUT LOCATION
856 603 TOILET AND BATHING ROOMS
TABLE 603.6 MAXIMUM REACH DEPTH AND HEIGHT
604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 604.2 WATER CLOSET LOCATION
857 FIGURE 604.3 SIZE OF CLEARANCE FOR WATER CLOSET
FIGURE 604.4 WATER CLOSET SEAT HEIGHT
FIGURE 604.5.1 SIDE WALL GRAB BAR FOR WATER CLOSET
858 FIGURE 604.5.2 REAR WALL GRAB BAR FOR WATER CLOSET
859 FIGURE 604.7 DISPENSER OUTLET LOCATION
FIGURE 604.9.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS
860 TABLE 604.9.3.1—DOOR OPENING LOCATION
FIGURE 604.9.3.1 WHEELCHAIR ACCESSIBLE COMPARTMENT DOOR OPENINGS
861 FIGURE 604.9.3.1 (C) WHEELCHAIR ACCESSIBLE COMPARTMENT DOOR OPENINGS—ALTERNATE
FIGURE 604.9.5 WHEELCHAIR ACCESSIBLE COMPARTMENT TOE CLEARANCE
862 FIGURE 604.10 AMBULATORY ACCESSIBLE COMPARTMENT
FIGURE 604.11.2 CHILDREN’S WATER CLOSET LOCATION
FIGURE 604.11.4 CHILDREN’S WATER CLOSET HEIGHT
863 FIGURE 604.11.7 CHILDREN’S DISPENSER OUTLET LOCATION
605 URINALS
FIGURE 605.2 HEIGHT OF URINALS
606 LAVATORIES AND SINKS
864 FIGURE 606.3 HEIGHT OF LAVATORIES AND SINKS
607 BATHTUBS
FIGURE 607.2 CLEARANCE FOR BATHTUBS
865 FIGURE 607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
FIGURE 607.4.2 GRAB BARS FOR BATHTUBS WITHOUT PERMANENT SEATS
866 FIGURE 607.5 LOCATION OF BATHTUB CONTROLS
608 SHOWER COMPARTMENTS
FIGURE 608.2.1 TRANSFER-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
867 FIGURE 608.2.2 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 608.3.1 GRAB BARS IN TRANSFER-TYPE SHOWERS
FIGURE 608.2.3 ALTERNATE ROLL-IN-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
868 FIGURE 608.3.2 GRAB BARS IN STANDARD ROLL-IN-TYPE SHOWERS
FIGURE 608.3.3 GRAB BARS IN ALTERNATE ROLL-IN-TYPE SHOWERS
FIGURE 608.4.1 TRANSFER-TYPE SHOWER CONTROLS AND HANDSHOWER LOCATION
FIGURE 608.4.2 STANDARD ROLL-IN-TYPE SHOWER CONTROL AND HANDSHOWER LOCATION
869 FIGURE 608.4.3 ALTERNATE ROLL-IN-TYPE SHOWER CONTROL AND HANDSHOWER LOCATION
870 609 GRAB BARS
FIGURE 609.2 SIZE OF GRAB BARS
FIGURE 609.3 SPACING OF GRAB BARS
871 FIGURE 609.4.2 POSITION OF CHILDREN’S GRAB BARS
610 SEATS
FIGURE 610.2 BATHTUB SEATS
872 FIGURE 610.3.1 RECTANGULAR SHOWER COMPARTMENT SEAT
FIGURE 610.3.2 L-SHAPED SHOWER COMPARTMENT SEAT
611 WASHING MACHINES AND CLOTHES DRYERS
612 SAUNAS AND STEAM ROOMS
873 FIGURE 611.2 CLEAR FLOOR SPACE
FIGURE 611.4 HEIGHT OF LAUNDRY EQUIPMENT
875 CHAPTER 7 COMMUNICATION ELEMENTS AND FEATURES
701 GENERAL
702 ALARMS
703 SIGNS
TABLE 703.2.4—VISUAL CHARACTER HEIGHT
876 FIGURE 703.3.5 CHARACTER HEIGHT
877 FIG. 703.3.10 HEIGHT OF RAISED CHARACTERS ABOVE FLOOR
FIGURE 703.3.11 LOCATION OF SIGNS AT DOORS
878 FIGURE 703.4.3 BRAILLE MEASUREMENT
TABLE 703.4.3— BRAILLE DIMENSIONS
879 FIGURE 703.4.4 POSITION OF BRAILLE
FIGURE 703.5 PICTOGRAM FIELD
FIGURE 703.4.5 HEIGHT OF BRAILLE CHARACTERS ABOVE FLOOR
880 FIGURE 703.6.3.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY
FIGURE 703.6.3.2 INTERNATIONAL TTY SYMBOL
FIG. 703.6.3.3 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
FIGURE 703.6.3.4 VOLUME-CONTROLLED TELEPHONE
881 TABLE 703.7.4—LOW RESOLUTION VMS CHARACTER HEIGHT
TABLE 703.7.5 PIXEL COUNT FOR LOW RESOLUTION VMS SIGNAGE
882 FIGURE 703.7.5 LOW RESOLUTION VMS SIGNAGE CHARACTERS
704 TELEPHONES
883 FIGURE 704.2.1 CLEAR FLOOR SPACE FOR TELEPHONES
705 DETECTABLE WARNINGS
706 ASSISTIVE LISTENING SYSTEMS
884 FIGURE 705.5 TRUNCATED DOME SIZE AND SPACING
707 AUTOMATIC TELLER MACHINES (ATMS) AND FARE MACHINES
FIGURE 707.5 NUMERIC KEY LAYOUT
885 TABLE 707.6.1—RAISED SYMBOLS
708 TWO-WAY COMMUNICATION SYSTEMS
887 CHAPTER 8 SPECIAL ROOMS AND SPACES
801 GENERAL
802 ASSEMBLY AREAS
FIGURE 802.3 WIDTH OF A WHEELCHAIR SPACE IN ASSEMBLY AREAS
FIGURE 802.4 DEPTH OF A WHEELCHAIR SPACE IN ASSEMBLY AREAS
888 FIGURE 802.9.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS
889 FIGURE 802.9.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS
FIGURE 802.9.2 LINE OF SIGHT OVER STANDING SPECTATORS
890 TABLE 802.9.2.2 REQUIRED WHEELCHAIR SPACE LOCATION ELEVATION OVER STANDING SPECTATORS
TABLE 802.10 WHEELCHAIR SPACE LOCATION DISPERSION
891 803 DRESSING, FITTING, AND LOCKER ROOMS
804 KITCHENS AND KITCHENETTES
FIGURE 804.2.1 PASS-THROUGH KITCHEN CLEARANCE
892 FIGURE 804.2.2 U-SHAPED KITCHEN CLEARANCE
893 805 TRANSPORTATION FACILITIES
FIGURE 805.2.2 SIZE OF BUS BOARDING AND ALIGHTING AREAS
894 FIGURE 805.3 BUS SHELTERS
FIGURE 805.10 TRACK CROSSINGS
895 806 HOLDING CELLS AND HOUSING CELLS
807 COURTROOMS
897 CHAPTER 9 BUILT-IN FURNISHINGS AND EQUIPMENT
901 GENERAL
902 DINING SURFACES AND WORK SURFACES
903 BENCHES
904 SALES AND SERVICE COUNTERS
898 FIGURE 904.4.2 HEIGHT OF CHECKOUT COUNTERS
FIGURE 903 BENCHES
899 905 STORAGE FACILITIES
901 CHAPTER 10 DWELLING UNITS AND SLEEPING UNITS
1001 GENERAL
1002 ACCESSIBLE UNITS
902 1003 TYPE A UNITS
904 FIGURE 1003.11.2.4 WATER CLOSETS IN TYPE A UNITS
905 FIGURE 1003.11.2.5.1 CLEARANCE FOR BATHTUBS IN TYPE A UNITS
FIGURE 1003.11.2.5.2 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT IN TYPE A UNITS
906 FIGURE 1003.12.1.1 MINIMUM KITCHEN CLEARANCE IN TYPE A UNITS
907 FIGURE 1003.12.1.2 U-SHAPED KITCHEN CLEARANCE IN TYPE A UNITS
FIGURE 1003.12.3 WORK SURFACE IN KITCHEN FOR TYPE A UNITS
FIGURE 1003.12.4 KITCHEN SINK FOR TYPE A UNITS
908 1004 TYPE B UNITS
910 FIGURE 1004.11.1.1 SWING-UP GRAB BAR FOR WATER CLOSET
911 FIGURE 1004.11.3.1.1 LAVATORY IN TYPE B UNITS—OPTION A BATHROOMS
912 FIGURE 1004.11.3.1.2 CLEARANCE AT WATER CLOSETS IN TYPE B UNITS
FIGURE 1004.11.3.1.3.1 PARALLEL APPROACH BATHTUB IN TYPE B UNITS—OPTION A BATHROOMS
913 FIGURE. 1004.11.3.1.3.2 FORWARD APPROACH BATHTUB IN TYPE B UNITS—OPTION A BATHROOMS
FIGURE 1004.11.3.1.3.3 TRANSFER-TYPE SHOWER COMPARTMENT IN TYPE B UNITS
FIGURE 1004.11.3.2.1 LAVATORY IN TYPE B UNITS—OPTION B BATHROOMS
FIGURE 1004.11.3.2.3.1 BATHROOM CLEARANCE IN TYPE B UNITS—OPTION B BATHROOMS
914 FIGURE 1004.12.1.1 MINIMUM KITCHEN CLEARANCE IN TYPE B UNITS
FIGURE 1004.12.1.2 U-SHAPED KITCHEN CLEARANCE IN TYPE B UNITS
915 1005 TYPE C (VISITABLE) UNITS
916 1006 UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
917 CHAPTER 11 RECREATIONAL FACILITIES
1101 GENERAL
1102 AMUSEMENT RIDES
918 FIGURE 1102.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDE
1103 RECREATIONAL BOATING FACILITIES
919 FIGURE 1103.3.1(A) BOAT SLIP CLEARANCE
FIGURE 1103.3.1(B) (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
FIGURE 1103.3.1(C) (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS
921 FIGURE 1103.3.2(A) BOARDING PIER CLEARANCE
FIGURE 1103.3.2(B) (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
1104 EXERCISE MACHINES AND EQUIPMENT
1105 FISHING PIERS AND PLATFORMS
922 FIGURE 1103.3.2(C) (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS
FIGURE 1105.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
923 1106 GOLF FACILITIES
1107 MINIATURE GOLF FACILITIES
1108 PLAY AREAS
924 FIGURE 1107.3.2 GOLF CLUB REACH RANGE AREA
925 TABLE 1108.3.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
926 FIGURE 1108.4.2.1 TRANSFER PLATFORMS
927 FIGURE 1108.4.2.2 TRANSFER STEPS
1109 SWIMMING POOLS, WADING POOLS, HOT TUBS AND SPAS
928 FIGURE 1109.2.2 POOL LIFT SEAT LOCATION
FIGURE 1109.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 1109.2.4 POOL LIFT SEAT HEIGHT
929 FIGURE 1109.2.8 POOL LIFT SUBMERGED DEPTH
FIGURE 1109.3.2 SLOPED ENTRY SUBMERGED DEPTH
FIGURE 1109.3.3 HANDRAILS FOR SLOPED ENTRY
930 FIGURE 1109.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 1109.4.2 TRANSFER WALL HEIGHT
FIGURE 1109.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
931 FIGURE 1109.4.5 GRAB BARS FOR TRANSFER WALLS
FIGURE 1109.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 1109.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM
FIGURE 1109.5.4 TRANSFER STEPS
932 FIGURE 1109.5.6 SIZE OF TRANSFER STEPS
FIGURE 1109.5.7 GRAB BARS
1110 SHOOTING FACILITIES WIHT FIRING POSITIONS
933 INDEX
947 2018 ILLINOIS ACCESSIBILITY CODE (SECTION 502 )
PURPOSE
EFFECTIVE DATE
TYPOGRAPHIC CONVENTIONS
CHAPTER 5 GENERAL SITE AND BUILDING
SECTION 502 PARKING SPACES
FIGURE 502.2 VEHICLE PARKING SPACES
948 FIGURE 502.3 (A) PARKING SPACE ACCESS AISLE
FIGURE 502.3 (B) DIAGONAL PARKING SPACE ACCESS AISLE
949 FIGURE 502.6 (A) PARKING SIGN
950 FIGURE 502.6 (B) PARKING FINE SIGN
951 HELPFUL TOOLS FOR YOUR BUILDING CODE
952 S.K. GHOSH ASSOCIATES LLC, SEISMIC AND BUILDING CODE CONSULTING
953 ICC EVALUATION SERVICE
954 ICC’s DIGITAL CODES LIBRARY
]]>
IL ChicagoBuildingRehabilitationCode 2019 ?u=/product/publishers/il/il-chicagobuildingrehabilitationcode-2019/ Sun, 20 Oct 2024 04:19:50 +0000 Chicago Building Rehabilitation Code, Title 14R - with April 2022 Supplement
Published By Publication Date Number of Pages
IL 2019 291
]]>
The Chicago Building Rehabilitation Code,Title 14R regulates the repair, alteration, change of occupancy, addition to, and relocation of existing buildings and structures. The accessibility-related provisions of this code have been drafted to be consistent with the 2018 Illinois Accessibility Code and federal regulations for privately-funded construction. Effective December 1, 2019

PDF Catalog

PDF Pages PDF Title
1 2018 CHICAGO CONSTRUCTION CODES BUILDING REHABILITATION CODE TITLE 14R
2 COPYRIGHT
3 COPYRIGHT FOR THE APRIL 2022 SUPPLEMENT
4 CITY OF CHICAGO OFFICE OF MAYOR MAYOR’S MESSAGE
5 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
6 ABOUT THE CHICAGO CONSTRUCTION CODES
10 ACKNOWLEDGMENTS
18 PREFACE TO THE MODEL CODE
20 EFFECTIVE USE OF THE CHICAGO BUILDING REHABILITATION CODE
24 TABLE OF CONTENTS
26 TABLE OF SUPPLEMENTED PROVISIONS MARCH 2021
28 CHAPTER 1 SCOPE AND PURPOSE
SECTION 101 GENERAL
30 APRIL 2022 SUPPLEMENT TO CHAPTER 1 SCOPE AND PURPOSE
31 SECTION 101 GENERAL
33 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
37 APRIL 2022 SUPPLEMENT TO CHAPTER 2 DEFINITIONS
38 SECTION 202 GENERAL DEFINITIONS
40 CHAPTER 3 PROVISIONS FOR ALL COMPLIANCE METHODS
SECTION 301 ADMINISTRATION
SECTION 302 GENERAL PROVISIONS
41 SECTION 303 STRUCTURAL DESIGN LOADS AND EVALUATION AND DESIGN PROCEDURES
TABLE 303.3.1 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41 FOR COMPLIANCE WITH FULL SEISMIC FORCES
SECTION 304 IN-SITU LOAD TESTS
SECTION 305 ACCESSIBILITY FOR EXISTING BUILDINGS
42 TABLE 303.3.2 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41 FOR COMPLIANCE WITH REDUCED SEISMIC FORCES
43 TABLE 305.8.5 RAMPS
44 SECTION 306 REROOFING
45 SECTION 307 FIRE ESCAPES
46 SECTION 308 ELECTRICAL
SECTION 309 RESIDENTIAL OCCUPANCIES
47 TABLE 309.1.1 .MAXIMUM NUMBER OF STORIES ABOVE GRADE PLANE
48 APRIL 2022 SUPPLEMENT TO CHAPTER 3 PROVISIONS FOR ALL COMPLIANCE METHODS
49 SECTION 302 GENERAL PROVISIONS
SECTION 303 STRUCTURAL DESIGN LOADS AND EVALUATION AND DESIGN PROCEDURES
SECTION 305 ACCESSIBILITY FOR EXISTING BUILDINGS
50 SECTION 306 REROOFING
51 SECTION 309 RESIDENTIAL OCCUPANCIES
TABLE 309.1.1 MAXIMUM NUMBER OF STORIES ABOVE GRADE PLANE
53 CHAPTER 4 REPAIRS
SECTION 401 GENERAL
SECTION 402 BUILDING ELEMENTS AND MATERIALS
SECTION 403 FIRE PROTECTION
SECTION 404 MEANS OF EGRESS
SECTION 405 STRUCTURAL
54 SECTION 406 ELECTRICAL
SECTION 407 MECHANICAL
55 SECTION 408 PLUMBING
SECTION 409 LIGHT AND VENTILATION
57 APRIL 2022 SUPPLEMENT TO CHAPTER 4 REPAIRS
58 SECTION 402 BUILDING ELEMENTS AND MATERIALS
SECTION 405 STRUCTURAL
SECTION 409 LIGHT AND VENTILATION
60 CHAPTER 5 PRESCRIPTIVE COMPLIANCE METHOD
SECTION 501 GENERAL
SECTION 502 ADDITIONS
61 SECTION 503 ALTERATIONS
62 SECTION 504 FIRE ESCAPES
63 SECTION 505 [RESERVED]
SECTION 506 CHANGE OF OCCUPANCY
SECTION 507 HISTORIC BUILDINGS
64 APRIL 2022 SUPPLEMENT TO CHAPTER 5 PRESCRIPTIVE COMPLIANCE METHOD
65 SECTION 502 ADDITIONS
SECTION 503 ALTERATIONS
SECTION 507 [RESERVED]
67 CHAPTER 6 CLASSIFICATION OF WORK
SECTION 601 GENERAL
SECTION 602 ALTERATION—LEVEL 1
SECTION 603 ALTERATION—LEVEL 2
SECTION 604 ALTERATION—LEVEL 3
SECTION 605 CHANGE OF OCCUPANCY
SECTION 606 ADDITIONS
68 SECTION 607 HISTORIC BUILDINGS
SECTION 608 RELOCATED BUILDINGS
69 CHAPTER 7 ALTERATIONS—LEVEL 1
SECTION 701 GENERAL
SECTION 702 BUILDING ELEMENTS AND MATERIALS
70 SECTION 703 FIRE PROTECTION
SECTION 704 MEANS OF EGRESS
SECTION 705 REROOFING
SECTION 706 STRUCTURAL
SECTION 707 ENERGY CONSERVATION
71 APRIL 2022 SUPPLEMENT TO CHAPTER 7 ALTERATIONS—LEVEL 1
72 SECTION 702 BUILDING ELEMENTS AND MATERIALS
74 CHAPTER 8 ALTERATIONS—LEVEL 2
SECTION 801 GENERAL
SECTION 802 BUILDING ELEMENTS AND MATERIALS
76 SECTION 803 FIRE PROTECTION
77 SECTION 804 CARBON MONOXIDE DETECTION
78 SECTION 805 MEANS OF EGRESS
81 SECTION 806 STRUCTURAL
SECTION 807 ELECTRICAL
82 SECTION 808 MECHANICAL
SECTION 809 PLUMBING
SECTION 810 ENERGY CONSERVATION
84 APRIL 2022 SUPPLEMENT TO CHAPTER 8 ALTERATIONS—LEVEL 2
85 SECTION 801 GENERAL
SECTION 802 BUILDING ELEMENTS AND MATERIALS
87 SECTION 803 FIRE PROTECTION
88 SECTION 804 CARBON MONOXIDE DETECTION
SECTION 805 MEANS OF EGRESS
90 TABLE 805.6 MAXIMUM LENGTH OF DEAD-END CORRIDORS (feet)
91 SECTION 806 STRUCTURAL
92 SECTION 807 ELECTRICAL
SECTION 808 MECHANICAL
SECTION 809 PLUMBING
SECTION 810 ENERGY CONSERVATION
93 CHAPTER 9 ALTERATIONS—LEVEL 3
SECTION 901 GENERAL
SECTION 902 SPECIAL USE AND OCCUPANCY
SECTION 903 BUILDING ELEMENTS AND MATERIALS
SECTION 904 FIRE PROTECTION
94 SECTION 905 MEANS OF EGRESS
SECTION 906 STRUCTURAL
95 SECTION 907 ENERGY CONSERVATION
97 APRIL 2022 SUPPLEMENT TO CHAPTER 9 ALTERATIONS—LEVEL 3
98 SECTION 902 SPECIAL USE AND OCCUPANCY
SECTION 903 BUILDING ELEMENTS AND MATERIALS
SECTION 904 FIRE PROTECTION
99 SECTION 905 MEANS OF EGRESS
100 CHAPTER 10 CHANGE OF OCCUPANCY
SECTION 1001 GENERAL
SECTION 1002 CREATION OF INCIDENTAL USES AND SPECIAL USES OCCUPANCIES
SECTION 1003 [RESERVED]
SECTION 1004 [RESERVED]
SECTION 1005 [RESERVED]
SECTION 1006 STRUCTURAL
101 SECTION 1007 ELECTRICAL
SECTION 1008 MECHANICAL
SECTION 1009 PLUMBING
SECTION 1010 LIGHT AND VENTILATION
SECTION 1011 CHANGE OF OCCUPANCY
102 TABLE 1011.4 MEANS OF EGRESS HAZARD CATEGORIES
103 TABLE 1011.5 HEIGHTS AND AREAS HAZARD CATEGORIES
TABLE 1011.6 EXPOSURE OF EXTERIOR WALLS HAZARD CATEGORIES
106 APRIL 2022 SUPPLEMENT TO CHAPTER 10 CHANGE OF OCCUPANCY
107 SECTION 1001 GENERAL
SECTION 1002 CREATION OF INCIDENTAL USES AND SPECIAL USES AND OCCUPANCIES
SECTION 1006 STRUCTURAL
SECTION 1011 CHANGE OF OCCUPANCY
111 CHAPTER 11 ADDITIONS
SECTION 1101 GENERAL
SECTION 1102 HEIGHTS AND AREAS
SECTION 1103 STRUCTURAL
112 SECTION 1104 SMOKE ALARMS IN OCCUPANCY GROUPS R AND I-1
SECTION 1105 CARBON MONOXIDE ALARMS IN GROUPS I-1, I-2, I-4 AND R
SECTION 1106 [RESERVED]
SECTION 1107 ENERGY CONSERVATION
113 APRIL 2022 SUPPLEMENT TO CHAPTER 11 ADDITIONS
114 SECTION 1102 HEIGHTS AND AREAS
SECTION 1105 CARBON MONOXIDE ALARMS IN GROUPS E, I-1, I-2, I-4 AND R
116 CHAPTER 12 HISTORIC BUILDINGS
SECTION 1201 GENERAL
SECTION 1202 REPAIRS
SECTION 1203 FIRE SAFETY
117 SECTION 1204 CHANGE OF OCCUPANCY
118 SECTION 1205 STRUCTURAL
SECTION 1206 RELOCATED BUILDINGS
120 APRIL 2022 SUPPLEMENT TO CHAPTER 12 HISTORIC BUILDINGS
121 SECTION 1201 GENERAL
SECTION 1203 FIRE SAFETY
SECTION 1204 CHANGE OF OCCUPANCY
SECTION 1205 STRUCTURAL
123 CHAPTER 13 PERFORMANCE COMPLIANCE METHODS
SECTION 1301 GENERAL
124 EQUATION 13-1
EQUATION 13-2
125 EQUATION 13-3
EQUATION 13-4
TABLE 1301.6.3 COMPARTMENTATION VALUES
TABLE 1301.6.4 SEPARATION VALUES
126 TABLE 1301.6.5 CORRIDOR WALL VALUES
TABLE 1301.6.6(1) VERTICAL OPENING PROTECTION VALUE
TABLE 1301.6.6(2) CONSTRUCTION-TYPE FACTOR
EQUATION 13-5
127 TABLE 1301.6.8 AUTOMATIC FIRE DETECTION VALUES
TABLE 1301.6.9 FIRE ALARM SYSTEM VALUES
TABLE 1301.6.10 SMOKE CONTROL VALUES
128 TABLE 1301.6.11 MEANS OF EGRESS VALUESa
TABLE 1301.6.12 DEAD-END VALUES
129 EQUATION 13-6
TABLE 1301.6.14 ELEVATOR CONTROL VALUES
TABLE 1301.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES
TABLE 1301.6.16 MIXED OCCUPANCY VALUESa
130 TABLE 1301.6.17 SPRINKLER SYSTEM VALUES
TABLE 1301.6.18 STANDPIPE SYSTEM VALUES
TABLE 1301.6.19 INCIDENTAL USE AREA VALUES
131 TABLE 1301.8 MANDATORY SAFETY SCORESa
132 TABLE 1301.7 SUMMARY SHEET—BUILDING CODE
133 APRIL 2022 SUPPLEMENT TO CHAPTER 13 PERFORMANCE COMPLIANCE METHODS
134 SECTION 1301 GENERAL
135 TABLE 1301.6.4 SEPARATION VALUES
TABLE 1301.6.11 MEANS OF EGRESS VALUES
TABLE 1301.8 MANDATORY SAFETY SCORESa
136 CHAPTER 14 RELOCATED OR MOVED BUILDINGS
SECTION 1401 GENERAL
SECTION 1402 REQUIREMENTS
138 CHAPTER 15 WORK SITE SAFETY AND OPERATIONS
SECTION 1501 GENERAL
140 CHAPTER 16 REFERENCED STANDARDS
SECTION 1601 REFERENCED STANDARDS
142 CHAPTER 17 APPENDICES AND RESOURCES
APPENDICES A THROUGH C [RESERVED]
RESOURCE A GUIDELINES ON FIRE RATINGS OF ARCHAIC MATERIALS AND ASSEMBLIES
143 RESOURCE A GUIDELINES ON FIRE RATINGS OF ARCHAIC MATERIALS AND ASSEMBLIES
INTRODUCTION
PURPOSE
144 1 FIRE-RELATED PERFORMANCE OF ARCHAIC MATERIALS AND ASSEMBLIES
1.1 FIRE PERFORMANCE MEASURES
145 1.2 COMBUSTIBLE CONSTRUCTION TYPES
2 BUILDING EVALUATION
2.1 PRELIMINARY EVALUATION
146 FIGURE 1 PRELIMINARY EVALUATION FIELD NOTES
147 FIGURE 2 PRELIMINARY EVALUATION WORKSHEET
148 2.2 FIRE RESISTANCE OF EXISTING BUILDING ELEMENTS
2.3 EFFECTS OF PENETRATIONS IN FIRE RESISTANT ASSEMBLIES
3 FINAL EVALUATION AND DESIGN SOLUTION
149 3.1 THE EXPERIMENTAL APPROACH
3.2 THE THEORETICAL APPROACH
HARMATHY’S TEN RULES
151 ILLUSTRATION OF HARMATHY’S RULES
EXAMPLE APPLICATION OF HARMATHY’S RULES
153 3.3“ THICKNESS DESIGN” STRATEGY
3.4 EVALUATION OF DOORS
154 FIGURE 3 MODIFICATION DETAILS
155 4 SUMMARY
156 APPENDIX
RESOURCE A TABLE OF CONTENTS
158 PURPOSE AND PROCEDURE
159 SECTION I – WALLS
FIGURE 1.1.1 MASONRY WALLS 0″ TO LESS THAN 4″ THICK
TABLE 1.1.1 MASONRY WALLS 0″ TO LESS THAN 4″ THICK
160 TABLE 1.1.1—continued MASONRY WALLS 0″ TO LESS THAN 4″ THICK
161 TABLE 1.1.1—continued MASONRY WALLS 0″ TO LESS THAN 4″ THICK
162 FIGURE 1.1.2 MASONRY WALLS 4″ TO LESS THAN 6″ THICK
TABLE 1.1.2 MASONRY WALLS 4″ TO LESS THAN 6″ THICK
163 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
164 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
165 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
166 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
167 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
168 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
169 FIGURE 1.1.3 MASONRY WALLS 6″ TO LESS THAN 8″ THICK
TABLE 1.1.3 MASONRY WALLS 6″ TO LESS THAN 8″ THICK
170 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
171 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
172 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
173 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
174 FIGURE 1.1.4 MASONRY WALLS 8″ TO LESS THAN 10″ THICK
TABLE 1.1.4 MASONRY WALLS 8″ TO LESS THAN 10″ THICK
175 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
176 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
177 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
178 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
179 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
180 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
181 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
182 FIGURE 1.1.5 MASONRY WALLS 10″ TO LESS THAN 12″ THICK
TABLE 1.1.5 MASONRY WALLS 10″ TO LESS THAN 12″ THICK
183 TABLE 1.1.5—continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK
184 TABLE 1.1.5—continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK
185 TABLE 1.1.5—continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK
186 FIGURE 1.1.6 MASONRY WALLS 12″ TO LESS THAN 14″ THICK
TABLE 1.1.6 MASONRY WALLS 12″ TO LESS THAN 14″ THICK
187 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
188 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
189 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
190 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
191 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
192 FIGURE 1.1.7 MASONRY WALLS 14″ OR MORE THICK
TABLE 1.1.7 MASONRY WALLS 14″ OR MORE THICK
193 TABLE 1.1.7—continued MASONRY WALLS 14″ OR MORE THICK
194 TABLE 1.1.7—continued MASONRY WALLS 14″ OR MORE THICK
195 FIGURE 1.2.1 METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
TABLE 1.2.1 METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
196 TABLE 1.2.1—continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
197 TABLE 1.2.1—continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
198 TABLE 1.2.1—continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
199 FIGURE 1.2.2 METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK
TABLE 1.2.2 METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK
200 TABLE 1.2.2—continued METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK
201 TABLE 1.2.3 METAL FRAME WALLS 6″ TO LESS THAN 8″ THICK
202 TABLE 1.2.4 METAL FRAME WALLS 8″ TO LESS THAN 10″ THICK
203 TABLE 1.3.1 WOOD FRAME WALLS 0″ TO LESS THAN 4″ THICK
204 FIGURE 1.3.2 WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
TABLE 1.3.2 WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
205 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
206 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
207 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
208 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
209 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
210 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
211 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
212 TABLE 1.3.3 WOOD FRAME WALLS 6″ TO LESS THAN 8″ THICK
TABLE 1.4.1 MISCELLANEOUS MATERIALS WALLS 0″ TO LESS THAN 4″ THICK
213 TABLE 1.4.2 MISCELLANEOUS MATERIALS WALLS 4″ TO LESS THAN 6″ THICK
214 FIGURE 1.5.1 FINISH RATINGS—INORGANIC MATERIALS
TABLE 1.5.1 FINISH RATINGS—INORGANIC MATERIALS
215 TABLE 1.5.1—continued FINISH RATINGS—INORGANIC MATERIALS
TABLE 1.5.2 FINISH RATINGS—ORGANIC MATERIALS
216 SECTION II COLUMNS
TABLE 2.1.1 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 0″ TO LESS THAN 6″
217 FIGURE 2.1.2 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
TABLE 2.1.2 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
218 TABLE 2.1.2—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
219 TABLE 2.1.2—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
220 TABLE 2.1.3 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 12″ TO LESS THAN 14″
221 TABLE 2.1.4 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 14″ TO LESS THAN 16″
222 FIGURE 2.1.5 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″
TABLE 2.1.5 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″
223 TABLE 2.1.5—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″
224 TABLE 2.1.6 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 18″ TO LESS THAN 20″
225 FIGURE 2.1.7 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″
TABLE 2.1.7 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″
226 TABLE 2.1.7—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″
TABLE 2.1.8 HEXAGONAL REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 12″ TO LESS THAN 14″
227 TABLE 2.1.9 HEXAGONAL REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 14″ TO LESS THAN 16″
TABLE 2.1.10 HEXAGONAL REINFORCED CONCRETE COLUMNS DIAMETER—16″ TO LESS THAN 18″
TABLE 2.1.11 HEXAGONAL REINFORCED CONCRETE COLUMNS DIAMETER—20″ TO LESS THAN 22″
228 TABLE 2.2 ROUND CAST IRON COLUMNS
229 FIGURE 2.3 STEEL COLUMNS-GYPSUM ENCASEMENTS
TABLE 2.3 STEEL COLUMNS—GYPSUM ENCASEMENTS
230 TABLE 2.3—continued STEEL COLUMNS—GYPSUM ENCASEMENTS
TABLE 2.4 TIMBER COLUMNS MINIMUM DIMENSION
TABLE 2.5.1.1 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION LESS THAN 6
231 TABLE 2.5.1.2 STEEL COLUMNS—CONCRETE ENCASEMENTS 6″ TO LESS THAN 8″ THICK
232 FIGURE 2.5.1.3 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
TABLE 2.5.1.3 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
233 TABLE 2.5.1.3—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
234 FIGURE 2.5.1.4 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
TABLE 2.5.1.4 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
235 TABLE 2.5.1.4—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
236 TABLE 2.5.1.4—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
237 TABLE 2.5.1.4—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
238 FIGURE 2.5.1.5 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
TABLE 2.5.1.5 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
239 TABLE 2.5.1.5—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
240 FIGURE 2.5.1.6 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″
TABLE 2.5.1.6 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″
241 TABLE 2.5.1.6—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″
242 TABLE 2.5.1.7 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 16″ TO LESS THAN 18″
TABLE 2.5.2.1 STEEL COLUMNS—BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
243 TABLE 2.5.2.2 STEEL COLUMNS—BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
TABLE 2.5.2.3 STEEL COLUMNS—BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″
244 TABLE 2.5.3.1 STEEL COLUMNS—PLASTER ENCASEMENTS MINIMUM DIMENSION 6″ TO LESS THAN 8″
TABLE 2.5.3.2 STEEL COLUMNS—PLASTER ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
TABLE 2.5.4.1 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 6″ TO LESS THAN 8″
245 TABLE 2.5.4.2 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
TABLE 2.5.4.3 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
TABLE 2.5.4.4 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
246 SECTION III FLOOR/CEILING ASSEMBLIES
FIGURE 3.1 FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
TABLE 3.1 FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
247 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
248 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
249 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
250 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
251 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
252 FIGURE 3.2 FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
TABLE 3.2 FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
253 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
254 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
255 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
256 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
257 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
258 FIGURE 3.3 FLOOR/CEILING ASSEMBLIES—WOOD JOIST
TABLE 3.3 FLOOR/CEILING ASSEMBLIES—WOOD JOIST
259 TABLE 3.3—continued FLOOR/CEILING ASSEMBLIES—WOOD JOIST
260 TABLE 3.3—continued FLOOR/CEILING ASSEMBLIES—WOOD JOIST
261 TABLE 3.3—continued FLOOR/CEILING ASSEMBLIES—WOOD JOIST
262 FIGURE 3.4 FLOOR/CEILING ASSEMBLIES—HOLLOW CLAY TILE WITH REINFORCED CONCRETE
TABLE 3.4 FLOOR/CEILING ASSEMBLIES—HOLLOW CLAY TILE WITH REINFORCED CONCRETE
263 TABLE 3.4—continued FLOOR/CEILING ASSEMBLIES—HOLLOW CLAY TILE WITH REINFORCED CONCRETE
264 TABLE 3.4—continued FLOOR/CEILING ASSEMBLIES-HOLLOW CLAY TILE WITH REINFORCED CONCRETE
265 SECTION IV BEAMS
TABLE 4.1.1 REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″
266 TABLE 4.1.1—continued REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″
267 TABLE 4.1.1—continued REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″
268 TABLE 4.1.2 REINFORCED CONCRETE BEAMS DEPTH 12″ TO LESS THAN 14″
269 TABLE 4.1.2—continued REINFORCED CONCRETE BEAMS DEPTH 12″ TO LESS THAN 14″
270 TABLE 4.1.3 REINFORCED CONCRETE BEAMS DEPTH 14″ TO LESS THAN 16″
271 TABLE 4.2.1 REINFORCED CONCRETE BEAMS—UNPROTECTED DEPTH 10″ TO LESS THAN 12″
TABLE 4.2.2 STEEL BEAMS—CONCRETE PROTECTION DEPTH 10″ TO LESS THAN 12″
272 SECTION V DOORS
FIGURE 5.1 RESISTANCE OF DOORS TO FIRE EXPOSURE
TABLE 5.1 RESISTANCE OF DOORS TO FIRE EXPOSURE
273 TABLE 5.1—continued RESISTANCE OF DOORS TO FIRE EXPOSURE
274 TABLE 5.1—continued RESISTANCE OF DOORS TO FIRE EXPOSURE
275 BIBLIOGRAPHY
282 INDEX
288 ICC EVALUATION SERVICE
289 S.K. GHOSH ASSOCIATES LLC
290 ICC PLAN REVIEW
291 HELPFUL TOOLS FOR YOUR EXISTING BUILDING CODE
]]>
IL ChicagoAdministrativeProvisions 2019 ?u=/product/publishers/il/il-chicagoadministrativeprovisions-2019/ Sun, 20 Oct 2024 04:19:50 +0000 Chicago Construction Codes Administrative Provisions, Title 14A - with April 2022 Supplement
Published By Publication Date Number of Pages
IL 2019
]]>
The Chicago Construction Codes Administrative Provisions (Title 14A) establish uniform administrative procedures for each code in the Chicago Construction Codes series. These provisions establish the limits of the applicability of each code and describe how the codes are to be applied and enforced. These provisions also establish the powers and responsibilities of city employees, design professionals, construction professionals, and building owners with respect to application of the Chicago Construction Codes. Effective July 1, 2019.

PDF Catalog

PDF Pages PDF Title
1 2019 THE CHICAGO CONSTRUCTIONS CODES ADMINISTRATIVE PROVISIONS TITLE 14A
2 COPYRIGHT
3 COPYRIGHT FOR THE MARCH 2021 SUPPLEMENT
4 CITY OF CHICAGO OFFICE OF THE MAYOR MAYOR’S MESSAGE
5 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
6 ABOUT THE CHICAGO CONSTRUCTION CODES
10 ACKNOWLEDGMENTS
18 EFFECTIVE USE OF THE CHICAGO CONSTRUCTION CODES ADMINISTRATIVE PROVISIONS
20 TABLE OF CONTENTS
22 TABLE OF SUPPLEMENTED PROVISIONS APRIL 2022
24 CHAPTER 14A-1 SCOPE AND APPLICATION
14A-1-101 GENERAL
14A-1-102 APPLICATION
25 14A-1-103 DEPARTMENT OF BUILDINGS
14A-1-104 DUTIES AND POWERS
27 14A-1-105 TRANSITIONAL PROVISIONS
30 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-1 SCOPE AND APPLICATION
31 14A-1-104 DUTIES AND POWERS
14A-1-105 TRANSITIONAL PROVISIONS
33 CHAPTER 14A-2 DEFINITIONS
14A-2-201 GENERAL
14A-2-202 DEFINITIONS
37 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-2 DEFINITIONS
38 14A-2-201 GENERAL
14A-2-202 DEFINITIONS
40 CHAPTER 14A-3 ENFORCEMENT
14A-3-301 GENERAL
41 14A-3-302 FINE
14A-3-303 INJUNCTION
14A-3-304 SUSPENSION OF PERMIT PRIVILEGES
43 14A-3-305 SUSPENSION OR REVOCATION OF TRADE LICENSE
14A-3-306 STOP WORK ORDER
44 14A-3-307 CLOSURE ORDER
45 14A-3-308 BUSINESS LICENSE REVOCATION
14A-3-309 BOARD UP
14A-3-310 UTILITY TERMINATION
14A-3-311 EMERGENCY DEMOLITION
14A-3-312 DANGEROUS AND UNSAFE OR UNCOMPLETED AND ABANDONED BUILDINGS
46 14A-3-313 NUISANCE ABATEMENT
47 14A-3-314 INCARCERATION
14A-3-315 OTHER EMERGENCY MEASURES
48 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-3 ENFORCEMENT
49 14A-3-301 GENERAL
14A-3-304 SUSPENSION OF PERMIT PRIVILEGES
50 14A-3-305 SUSPENSION OR REVOCATION OF TRADE LICENSE
14A-3-306 STOP WORK ORDER
14A-3-307 CLOSURE ORDER
14A-3-311 DEMOLITION
51 14A-3-313 NUISANCE ABATEMENT
52 14A-3-314 INCARCERATION
53 CHAPTER 14A-4 PERMITS
14A-4-401 GENERAL
54 14A-4-402 WORK EXEMPT FROM PERMIT
56 14A-4-403 MONTHLY PERMITS
14A-4-404 ADDITIONAL REQUIREMENTS BASED ON SCOPE OF WORK
60 14A-4-405 TEMPORARY STRUCTURES AND USES
14A-4-406 EXCAVATION WORK ON PRIVATE PROPERTY
61 14A-4-407 DEMOLITION
63 14A-4-408 [RESERVED]
14A-4-409 PRE-APPLICATION SERVICES
64 14A-4-410 APPLICATIONS
14A-4-411 SUPPORTING DOCUMENTS
67 14A-4-412 FEES
68 14A-4-413 LIMITATIONS
71 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-4 PERMITS
72 14A-4-401 GENERAL
14A-4-402 WORK EXEMPT FROM PERMIT
74 14A-4-404 ADDITIONAL REQUIREMENTS BASED ON SCOPE OF WORK
14A-4-405 TEMPORARY STRUCTURES AND USES
14A-4-406 EXCAVATION WORK ON PRIVATE PROPERTY
75 14A-4-407 DEMOLITION
76 14A-4-409 PRE-APPLICATION SERVICES
14A-4-410 APPLICATIONS
14A-4-411 SUPPORTING DOCUMENTS
14A-4-412 FEES
77 14A-4-413 LIMITATIONS
80 CHAPTER 14A-5 INSPECTION AND OBSERVATION OF PERMITTED WORK
14A-5-501 GENERAL
14A-5-502 REGULAR INSPECTIONS
82 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-5 INSPECTION AND OBSERVATION OF PERMITTED WORK
83 14A-5-502 REGULAR INSPECTIONS
14A-5-503 DEMOLITION INSPECTIONS
85 CHAPTER 14A-6 INSPECTION OF EXISTING STRUCTURES AND SYSTEMS
14A-6-601 GENERAL
14A-6-602 INSPECTION BASED ON OCCUPANCY
86 14A-6-603 CONDITION ASSESSMENT
87 14A-6-604 BUILDING FEATURES
14A-6-605 CONVEYANCE DEVICES
88 14A-6-606 MECHANICAL EQUIPMENT
14A-6-607 SIGNS
89 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-6 INSPECTION OF EXISTING STRUCTURES AND SYSTEMS
90 14A-6-601 GENERAL
14A-6-603 CONDITION ASSESSMENT
14A-6-606 MECHANICAL EQUIPMENT
14A-6-608 PROBLEM BUILDINGS
92 CHAPTER 14A-7 OCCUPANCY
14A-7-701 GENERAL
14A-7-702 CERTIFICATES OF OCCUPANCY
14A-7-703 THEATERS AND PUBLIC AMUSEMENTS
93 14A-7-704 SERVICE UTILITIES
94 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-7 ADMINISTRATIVE PROVISIONS
95 14A-7-702 CERTIFICATES OF OCCUPANCY
14A-7-703 THEATERS AND PUBLIC AMUSEMENTS
97 CHAPTER 14A-8 POSTING REQUIREMENTS
14A-8-801 GENERAL
14A-8-802 MAXIMUM CAPACITY SIGNS
14A-8-803 FLOOR LOADS
98 14A-8-804 ASSEMBLY OCCUPANCIES
99 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-8 POSTING REQUIREMENTS
100 14A-8-802 MAXIMUM CAPACITY SIGNS
102 CHAPTER 14A-9 [RESERVED]
104 CHAPTER 14A-10 APPROVALS AND APPEALS
14A-10-1001 GENERAL
14A-10-1002 FORMAL INTERPRETATIONS
14A-10-1003 ALTERNATIVE CODE APPROVAL
105 14A-10-1004 COMMITTEE ON STANDARDS AND TESTS
14A-10-1005 BUILDING BOARD OF APPEALS
108 CHAPTER 14A-11 REFERENCED STANDARDS
14A-11-1101 GENERAL
110 CHAPTER 14A-12 SCHEDULES
14A-12-1201 GENERAL
14A-12-1202 [RESERVED]
14A-12-1203 CHAPTER 3
TABLE 14A-12-1203.1 FEES, FINES, AND PENALTIES—CHAPTER 3
TABLE 14A-12-1203.2 SPECIALIZED FINES
111 14A-12-1204 CHAPTER 4
TABLE 14A-12-1204.1 GENERAL FEES—CHAPTER 4
TABLE 14A-12-1204.2 STAND ALONE PERMIT FEES
112 TABLE 14A-12-1204.2—continued STAND ALONE PERMIT FEES
113 TABLE 14A-12-1204.2—continued STAND ALONE PERMIT FEES
114 TABLE 14A-12-1204.2—continued STAND ALONE PERMIT FEES
115 TABLE 14A-12-1204.3(1) CONSTRUCTION FACTOR FOR NEW CONSTRUCTION
116 TABLE 14A-12-1204.3(2) CONSTRUCTION FACTOR FOR REHABILITATION
117 TABLE 14A-12-1204.3(3) SCOPE OF REVIEW FACTOR FOR NEW CONSTRUCTIONa
118 TABLE 14A-12-1204.3(3)—continued SCOPE OF REVIEW FACTOR FOR NEW CONSTRUCTIONa
119 TABLE 14A-12-1204.3(4) SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
120 TABLE 14A-12-1204.3(4)—continued SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
121 TABLE 14A-12-1204.3(4)—continued SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
122 TABLE 14A-12-1204.3(4)—continued SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
123 TABLE 14A-12-1204.3(4) —continuedSCOPE OF REVIEW FACTOR FOR REHABILITATIONa
124 TABLE 14A-12-1204.3(4) —continuedSCOPE OF REVIEW FACTOR FOR REHABILITATIONa
TABLE 14A-12-1204.3(5) SCOPE OF REVIEW FACTOR FOR EXTERIOR WALL REHABILITATIONa
TABLE 14A-12-1204.3(6) SCOPE OF REVIEW FACTOR FOR PHASED PERMITTINGa
125 TABLE 14A-12-1204.4 STOP WORK ORDER PENALTY
14A-12-1205 CHAPTER 5
TABLE 14A-12-1205.1 FEES—CHAPTER 5
126 14A-12-1206 CHAPTER 6
TABLE 14A-12-1206.1 FEES—CHAPTER 6
127 TABLE 14A-12-1206.1—continued FEES—CHAPTER 6
14A-12-1207 CHAPTER 7
TABLE 14A-12-1207.1 FEES—CHAPTER 7
14A-12-1208 CHAPTER 8
TABLE 14A-12-1208.1 FEES—CHAPTER 8
14A-12-1209 [RESERVED]
128 14A-12-1210 CHAPTER 10
TABLE 14A-12-1210.1 FEE—CHAPTER 10
130 APRIL 2022 SUPPLEMENT TO CHAPTER 14A-12 SCHEDULES
131 14A-12-1203 CHAPTER 3
TABLE 14A-12-1203.2 SPECIALIZED FINES
14A-12-1204 CHAPTER 4
132 TABLE 14A-12-1204.1 GENERAL FEES—CHAPTER 4
TABLE 14A-12-1204.2 STAND ALONE PERMIT FEES
133 TABLE 14A-12-1204.2—continued STAND ALONE PERMIT FEES
134 TABLE 14A-12-1204.2—continued STAND ALONE PERMIT FEES
135 TABLE 14A-12-1204.2—continued STAND ALONE PERMIT FEES
136 TABLE 1204.3(1) CONSTRUCTION FACTOR FOR ALL WORK TYPES
TABLE 14A-12-1204.3(2) [Reserved]
137 TABLE1204.3(3) SCOPE OF REVIEW FACTOR FOR NEW CONSTRUCTIONa
138 TABLE1204.3(3)—continued SCOPE OF REVIEW FACTOR FOR NEW CONSTRUCTIONa
139 TABLE 14A-12-1204.3(4) SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
140 TABLE 14A-12-1204.3(4)—continued SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
141 TABLE 14A-12-1204.3(4)—continued SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
142 TABLE 14A-12-1204.3(4)—continued SCOPE OF REVIEW FACTOR FOR REHABILITATIONa
143 TABLE 14A-12-1204.3(6) SCOPE OF REVIEW FACTOR FOR PHASED PERMITTINGa
144 14A-12-1206 CHAPTER 6
TABLE 14A-12-1206.1 FEES—CHAPTER 6
145 TABLE 14A-12-1206.1—continued FEES—CHAPTER 6
14A-12-1208 CHAPTER 8
TABLE 14A-12-1208.1 FEES—CHAPTER 8
14A-12-1210 CHAPTER 10
TABLE 14A-12-1210.1 FEE—CHAPTER 10
147 INDEX
153 GENERAL CODE, LLC
154 PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO)
155 ICC EVALUATION SERVICE
156 ICC DIGITAL CODES LIBRARY
157 ICC PLAN REVIEW
]]>
IL ChicagoExistingBuilding 2019 ?u=/product/publishers/il/il-chicagoexistingbuilding-2019/ Sun, 20 Oct 2024 04:19:50 +0000 Chicago Minimum Requirements for Existing Buildings, Title 14X - with April 2022 Supplement
Published By Publication Date Number of Pages
IL 2019 122
]]>
The Chicago Minimum Requirements for Existing Buildings, Title 14X regulate the condition and maintenance of existing buildings, existing structures, and outdoors areas, and establish the respective responsibilities of owners and occupants to comply with these requirements. This code also establishes minimum requirements for providing light, ventilation, space, security, electricity, plumbing, heating, cooling, sanitation, weather protection, and fire protection in occupied buildings, and requirements for the maintenance of vacant structures. These requirements apply both prospectively and retroactively. Unlike the International Codes® family, the Chicago Construction Codes do not (and are not intended to) include a separate code for one- and two-family residential buildings. Instead, one- to three-unit residential buildings up to four stories (single-family homes to three flats) are regulated in most titles of the Chicago Construction Codes as Occupancy Group R-5. There are numerous Chicago-specific exceptions applicable to Group R-5 occupancies. Additionally, in the Chicago Electrical Code, requirements for residential occupancies are collected in Article 560, and requirements applicable to the rehabilitation of residential buildings up to four stories are in Article 570. Effective date to be determined

PDF Catalog

PDF Pages PDF Title
1 2019 CHICAGO CONSTRUCTION CODES CHICAGO MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS TITLE 14X
2 COPYRIGHT
3 COPYRIGHT FOR THE APRIL 2022 SUPPLEMENT
4 CITY OF CHICAGO OFFICE OF THE MAYER MAYOR’S MESSAGE
5 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
6 ABOUT THE CHICAGO CONSTRUCTION CODES
10 ACKNOWLEDGMENTS
18 EFFECTIVE USE OF THE CHICAGO MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS
22 TABLE OF CONTENTS
24 TABLE OF SUPPLEMENTED PROVISIONS APRIL 2022
26 CHAPTER 14X-1 SCOPE AND APPLICATION
14X-1-101 GENERAL
14X-1-102 APPLICATION
14X-1-103 RESPONSIBILITY
27 14X-1-104 CONDITION REPORT
14X-1-105 PENALTIES AND REMEDIES
28 APRIL 2022 SUPPLEMENT TO CHAPER 14X-1 SCOPE AND APPLICATION
29 14X-1-103 RESPONSIBILITY
31 CHAPTER 14X-2 DEFINITIONS
14X-2-201 GENERAL
14X-2-202 DEFINITIONS
35 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-2 DEFINITIONS
36 14X-2-201 GENERAL
14X-2-202 DEFINITIONS
38 CHAPTER 14X-3 PROPERTY MAINTENANCE
14X-3-301 GENERAL
14X-3-302 OUTDOOR AREAS
14X-3-303 EXTERIOR STRUCTURE
40 14X-3-304 INTERIOR STRUCTURE
14X-3-305 COMPONENT SERVICEABILITY
41 14X-3-306 HANDRAILS AND GUARDRAILS
42 14X-3-307 RUBBISH AND GARBAGE
14X-3-308 PEST MANAGEMENT
44 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-3 PROPERTY MAINTENANCE
45 14X-3-302 OUTDOOR AREAS
A14X-3-303 EXTERIOR STRUCTURE
46 14X-3-304 INTERIOR STRUCTURE
14X-3-305 COMPONENT SERVICEABILITY
49 CHAPTER 14X-4 RESIDENTIAL OCCUPANCIES
14X-4-401 GENERAL
14X-4-402 ARRANGEMENT AND MINIMUM DIMENSIONS
TABLE 14X-4-402.3 MINIMUM UNIT AREA REQUIREMENTS
TABLE 14X-4-402.4 MINIMUM BEDROOM AREA REQUIREMENTS
14X-4-403 SECURITY DEVICES
51 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-4 RESIDENTIAL OCCUPANCIES
52 14X-4-402 ARRANGEMENT AND MINIMUM DIMENSIONS
14X-4-403 SECURITY DEVICES
54 CHAPTER 14X-5 FIRE SAFETY REQUIREMENTS
14X-5-501 GENERAL
TABLE 14X-5-501.2 OCCUPANCY- AND USE-BASED REQUIREMENTSa
55 TABLE 14X-5-501.2—continued OCCUPANCY- AND USE-BASED REQUIREMENTSa
14X-5-502 FIRE AND SMOKE PROTECTION FEATURES
57 14X-5-503 [RESERVED]
14X-5-504 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
61 14X-5-505 MEANS OF EGRESS
65 14X-5-506 LIFE SAFETY COMPLIANCE PLAN
66 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-5 FIRE SAFETY REQUIREMENTS
67 14X-5-501 GENERAL
14X-5-502 FIRE AND SMOKE PROTECTION FEATURES
14X-5-504 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
68 14X-5-505 MEANS OF EGRESS
69 14X-5-506 LIFE SAFETY COMPLIANCE PLAN
71 CHAPTER 14X-6 LIGHT AND VENTILATION
14X-6-601 GENERAL
14X-6-602 LIGHT
14X-6-603 VENTILATION
73 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-6 LIGHT AND VENTILATION
74 14X-6-602 LIGHT
76 CHAPTER 14X-7 ELECTRICAL REQUIREMENTS
14X-7-701 GENERAL
14X-7-702 ELECTRICAL SYSTEM
14X-7-703 ELECTRICAL EQUIPMENT
77 14X-7-704 EMERGENCY ELECTRICAL SYSTEM
14X-7-705 ELECTRICAL HAZARDS
78 APRIL 2022 SUPPLEMENT TO CHAPTER 14X7 ELECTRICAL REQUIREMENTS
79 14X-7-703 ELECTRICAL EQUIPMENT
14X-7-705 ELECTRICAL HAZARDS
81 CHAPTER 14X-8 HEATING, COOLING AND MECHANICAL SYSTEMS
14X-8-801 GENERAL
14X-8-802 HEATING SYSTEMS
14X-8-803 COOLING EQUIPMENT
82 14X-8-804 MECHANICAL EQUIPMENT
14X-8-805 DUCT SYSTEMS
83 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-8 HEATING, COOLING AND MECHANICAL SYSTEMS
84 14X-8-806 FUEL GAS PIPING
86 CHAPTER 14X-9 PLUMBING SYSTEMS AND FIXTURES
14X-9-901 GENERAL
14X-9-902 REQUIRED FIXTURES
14X-9-903 TOILET ROOMS AND BATHROOMS
14X-9-904 OPERATIONS AND MAINTENANCE
87 14X-9-905 WATER SYSTEMS
14X-9-906 SANITARY DRAINAGE SYSTEMS
14X-9-907 STORM DRAINAGE
14X-9-908 SWIMMING POOLS, SPAS, AND HOT TUBS
88 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-9 PLUMBING SYSTEMS AND FIXTURES
89 14X-9-902 REQUIRED FIXTURES
14X-9-903 TOILET ROOMS AND BATHROOMS
14X-9-905 WATER SYSTEMS
14X-9-908 SWIMMING POOLS, SPAS, AND HOT TUBS
91 CHAPTER 14X-10 ELEVATORS AND OTHER CONVEYANCE DEVICES
14X-10-1001 GENERAL
14X-10-1002 ELEVATORS
93 CHAPTER 14X-11 [RESERVED]
95 CHAPTER 14X-12 VACANT BUILDINGS
14X-12-1201 GENERAL
14X-12-1202 PROPERTY MAINTENANCE
97 14X-12-1203 INSURANCE
14X-12-1204 OWNER REGISTRATION
98 14X-12-1205 MORTGAGEE OBLIGATIONS
100 14X-12-1206 [RESERVED]
101 14X-12-1207 WATCHMAN
103 APRIL 2022 SUPPLEMENT TO CHAPTER 14X-12 VACANT BUILDINGS
104 14X-12-1202 PROPERTY MAINTENANCE
14X-12-1204 OWNER REGISTRATION
14X-12-1205 MORTGAGEE OBLIGATIONS
106 CHAPTERS 14X-13 THROUGH 14X-19 [RESERVED]
108 CHAPTER 14X-20 REFERENCED STANDARDS
14X-20-2001 GENERAL
110 INDEX
118 TELEWORK WITH ICC DIGITAL CODES PREMIUM
119 ICC EVALUATION SERVICE
120 ICC MEMBERSHIP
121 ICC ASSESSMENT CENTER
122 S.K. GHOSH ASSOCIATES
]]>
Chicago Minimum Requirements for Existing Buildings, Title 14X – with March 2021 Supplement:2019 Edition ?u=/product/publishers/il/chicago-minimum-requirements-for-existing-buildings-title-14x-with-march-2021-supplement/ Sun, 20 Oct 2024 02:37:40 +0000 Chicago Minimum Requirements for Existing Buildings, Title 14X - with March 2021 Supplement
Published By Publication Date Number of Pages
IL 2019
]]>
PDF Catalog
PDF Pages PDF Title
1 2019 CHICAGO CONSTRUCTION CODES CHICAGO MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS TITLE 14X
2 COPYRIGHT
3 COPYRIGHT FOR THE MARCH 2021 SUPPLEMENT
4 CITY OF CHICAGO OFFICE OF THE MAYER MAYOR’S MESSAGE
5 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
6 ABOUT THE CHICAGO CONSTRUCTION CODES
10 ACKNOWLEDGMENTS
18 EFFECTIVE USE OF THE CHICAGO MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS
22 TABLE OF CONTENTS
24 TABLE OF SUPPLEMENTED PROVISIONS MARCH 2021
26 CHAPTER 14X-1 SCOPE AND APPLICATION
14X-1-101 GENERAL
14X-1-102 APPLICATION
14X-1-103 RESPONSIBILITY
27 14X-1-104 CONDITION REPORT
14X-1-105 PENALTIES AND REMEDIES
28 CHAPTER 14X-2 DEFINITIONS
14X-2-201 GENERAL
14X-2-202 DEFINITIONS
32 MARCH 2021 SUPPLEMENT TO CHAPTER 14X-2 DEFINITIONS
33 14X-2-201 GENERAL
14X-2-202 DEFINITIONS
35 CHAPTER 14X-3 PROPERTY MAINTENANCE
14X-3-301 GENERAL
14X-3-302 OUTDOOR AREAS
14X-3-303 EXTERIOR STRUCTURE
37 14X-3-304 INTERIOR STRUCTURE
14X-3-305 COMPONENT SERVICEABILITY
38 14X-3-306 HANDRAILS AND GUARDRAILS
39 14X-3-307 RUBBISH AND GARBAGE
14X-3-308 PEST MANAGEMENT
41 MARCH 2021 SUPPLEMENT TO CHAPTER 14X-3 PROPERTY MAINTENANCE
42 14X-3-302 OUTDOOR AREAS
A14X-3-303 EXTERIOR STRUCTURE
43 14X-3-304 INTERIOR STRUCTURE
14X-3-305 COMPONENT SERVICEABILITY
46 CHAPTER 14X-4 RESIDENTIAL OCCUPANCIES
14X-4-401 GENERAL
14X-4-402 ARRANGEMENT AND MINIMUM DIMENSIONS
TABLE 14X-4-402.3 MINIMUM UNIT AREA REQUIREMENTS
TABLE 14X-4-402.4 MINIMUM BEDROOM AREA REQUIREMENTS
14X-4-403 SECURITY DEVICES
48 MARCH 2021 SUPPLEMENT TO CHAPTER 14X-4 RESIDENTIAL OCCUPANCIES
49 14X-4-402 ARRANGEMENT AND MINIMUM DIMENSIONS
14X-4-403 SECURITY DEVICES
51 CHAPTER 14X-5 FIRE SAFETY REQUIREMENTS
14X-5-501 GENERAL
TABLE 14X-5-501.2 OCCUPANCY- AND USE-BASED REQUIREMENTSa
52 TABLE 14X-5-501.2—continued OCCUPANCY- AND USE-BASED REQUIREMENTSa
14X-5-502 FIRE AND SMOKE PROTECTION FEATURES
54 14X-5-503 [RESERVED]
14X-5-504 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
58 14X-5-505 MEANS OF EGRESS
62 14X-5-506 LIFE SAFETY COMPLIANCE PLAN
63 MARCH 2021 SUPPLEMENT TO CHAPTER 14X-5 FIRE SAFETY REQUIREMENTS
64 14X-5-501 GENERAL
14X-5-502 FIRE AND SMOKE PROTECTION FEATURES
14X-5-504 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
65 14X-5-505 MEANS OF EGRESS
66 14X-5-506 LIFE SAFETY COMPLIANCE PLAN
68 CHAPTER 14X-6 LIGHT AND VENTILATION
14X-6-601 GENERAL
14X-6-602 LIGHT
14X-6-603 VENTILATION
70 MARCH 2021 SUPPLEMENT TO CHAPTER 14X-6LIGHT AND VENTILATION
71 14X-6-602 LIGHT
73 CHAPTER 14X-7 ELECTRICAL REQUIREMENTS
14X-7-701 GENERAL
14X-7-702 ELECTRICAL SYSTEM
14X-7-703 ELECTRICAL EQUIPMENT
74 14X-7-704 EMERGENCY ELECTRICAL SYSTEM
14X-7-705 ELECTRICAL HAZARDS
75 MARCH 2021 SUPPLEMENT TO CHAPTER 14X7 ELECTRICAL REQUIREMENTS
76 14X-7-703 ELECTRICAL EQUIPMENT
14X-7-705 ELECTRICAL HAZARDS
78 CHAPTER 14X-8 HEATING, COOLING AND MECHANICAL SYSTEMS
14X-8-801 GENERAL
14X-8-802 HEATING SYSTEMS
14X-8-803 COOLING EQUIPMENT
79 14X-8-804 MECHANICAL EQUIPMENT
14X-8-805 DUCT SYSTEMS
80 CHAPTER 14X-9 PLUMBING SYSTEMS AND FIXTURES
14X-9-901 GENERAL
14X-9-902 REQUIRED FIXTURES
14X-9-903 TOILET ROOMS AND BATHROOMS
14X-9-904 OPERATIONS AND MAINTENANCE
81 14X-9-905 WATER SYSTEMS
14X-9-906 SANITARY DRAINAGE SYSTEMS
14X-9-907 STORM DRAINAGE
14X-9-908 SWIMMING POOLS, SPAS, AND HOT TUBS
82 MARCH 2021 SUPPLEMENT TO CHAPTER 14X-9 PLUMBING SYSTEMS AND FIXTURES
83 14X-9-902 REQUIRED FIXTURES
14X-9-903 TOILET ROOMS AND BATHROOMS
14X-9-905 WATER SYSTEMS
14X-9-908 SWIMMING POOLS, SPAS, AND HOT TUBS
85 CHAPTER 14X-10 ELEVATORS AND OTHER CONVEYANCE DEVICES
14X-10-1001 GENERAL
14X-10-1002 ELEVATORS
87 CHAPTER 14X-11 [RESERVED]
89 CHAPTER 14X-12 VACANT BUILDINGS
14X-12-1201 GENERAL
14X-12-1202 PROPERTY MAINTENANCE
91 14X-12-1203 INSURANCE
14X-12-1204 OWNER REGISTRATION
92 14X-12-1205 MORTGAGEE OBLIGATIONS
94 14X-12-1206 [RESERVED]
95 14X-12-1207 WATCHMAN
97 MARCH 2021 SUPPLEMENT TO CHAPTER 14X-12 VACANT BUILDINGS
98 14X-12-1202 PROPERTY MAINTENANCE
14X-12-1205 MORTGAGEE OBLIGATIONS
100 CHAPTERS 14X-13 THROUGH 14X-19 [RESERVED]
102 CHAPTER 14X-20 REFERENCED STANDARDS
14X-20-2001 GENERAL
104 INDEX
112 ICC DIGITAL CODE LIBRARY
113 ICC MEMBERSHIP
114 ICC ASSESSMENT CENTER
115 S.K. GHOSH ASSOCIATES
]]>
IL ChicagoEnergyConservationCode 2019 ?u=/product/publishers/il/il-chicagoenergyconservationcode-2019/ Sun, 20 Oct 2024 02:37:39 +0000 Chicago Energy Conservation Code, Title 14N - with May 2020 Supplement
Published By Publication Date Number of Pages
IL 2019 180
]]>
The Chicago Energy Conservation Code, Title 14N regulates matters related to the design, construction, and rehabilitation of new and existing buildings for energy efficiency. This code has been drafted to be consistent with the 2019 Illinois amendments to the International Energy Conservation Code. This is a fully integrated codes based on the 2018 IECC. Effective June 1, 2019

PDF Catalog

PDF Pages PDF Title
1 2019 CHICAGO CONSTRUCTION CODES CHICAGO ENERGY CONSERVATION CODE TITLE 14N
2 COPYRIGHT
3 CITY OF CHICAGO OFFICE OF THE MAYOR MAYOR’S MESSAGE
4 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
5 ABOUT THE CHICAGO CONSTRUCTION CODES
9 ACKNOWLEDGMENTS
17 PREFACE TO THE MODEL CODE
21 EFFECTIVE USE OF THE CHICAGO ENERGY CONSERVATION CODE
25 TABLE OF CONTENTS
27 TABLE OF SUPPLEMENTED PROVISIONS
29 CECC—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
31 CHAPTER C1 SCOPE AND PURPOSE
SECTION C101 GENERAL
33 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
39 MAY 2020 SUPPLEMENT TO CHAPTER 2 [CE] DEFINITIONS
40 SECTION C202 GENERAL DEFINITIONS
42 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
44 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
45 EQUATION 4-1
EQUATION 4-2
TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
46 TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD
TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHOD
48 TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
EQUATION 4-4
49 EQUATION 4-5
51 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
52 SECTION C403 BUILDING MECHANICAL SYSTEMS
53 EQUATION 4-6
EQUATION 4-7
TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY
TABLE C403.3.4 BOILER TURNDOWN
54 TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
55 TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
56 TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
57 TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
58 TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
59 TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
60 TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
61 TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS
62 TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
63 TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT
66 TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
67 TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
71 TABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year)
TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
72 TABLE C403.8.1(1) FAN POWER LIMITATION
73 TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
74 TABLE C403.8.5.1 COOLING SYSTEMS
75 TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
76 TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
77 TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
79 TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
80 EQUATION 4-8
81 TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)
SECTION C404 SERVICE WATER HEATING (MANDATORY)
82 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
83 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
84 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
85 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
87 EQUATION 4-9
89 FIGURE C405.2.3.2 SIDELIT ZONE
FIGURE C405.2.3.3(1) TOPLIT ZONE
FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
90 FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
EQUATION 4-10
91 EQUATION 4-11
92 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
93 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
94 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
95 TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
96 TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
97 TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
98 TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b
99 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
100 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C406 ADDITIONAL EFFICIENCY PACKAGES
101 SECTION C407 TOTAL BUILDING PERFORMANCE
103 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
104 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
105 TABLE C407.5.1(2) HVAC SYSTEMS MAP
106 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
107 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
108 SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
111 FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST
112 MAY 2020 SUPPLEMENT TO CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
113 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
114 TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
115 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
117 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
118 SECTION C503 ALTERATIONS
119 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
121 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
122 AMCA
ANSI
APSP
ASHRAE
123 ASTM
CSA
124 CTI
DASMA
DOE
IEEE
IES
125 ISO
NEMA
NFRC
SMACNA
UL
US-FTC
126 WDMA
127 INDEX
137 CECC—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
139 CHAPTER 1 [RE] SCOPE AND PURPOSE
SECTION R101 GENERAL
141 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
145 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
146 TABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
147 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
148 TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE R402.1.4 EQUIVALENT U-FACTORSa
149 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES
152 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
153 SECTION R403 SYSTEMS
155 TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
TABLE R403.6.4.3(1) CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS
TABLE R403.6.4 INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORSa
156 EQUATION 4-1
TABLE R403.6.4.4 MINIMUM REQUIRED LOCAL EXHAUST RATE FOR DWELLING UNITS IN GROUP R-5 OCCUPANCIES
157 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
158 SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
159 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
160 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
161 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
162 EQUATION 4-2
TABLE R406.4 MAXIMUM ENERGY RATING INDEX
163 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
SECTION R502 ADDITIONS
164 SECTION R503 ALTERATIONS
165 SECTION R504 REPAIRS
SECTION R505 CHANGE OF OCCUPANCY OR USE
167 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
AMCA
APSP
ASHRAE
168 ASTM
CSA
DASMA
HVI
ICC
169 IEEE
NFRC
RESNET
UL
US-FTC
170 WDMA
171 INDEX
177 ICC EVALUATION SERVICE
178 ICC MEMBERSHIP
179 ICC ASSESSMENT CENTER
180 ICC DIGITAL CODES LIBRARY
]]>