IEEE STD C62.22 2009
$50.05
IEEE Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current Systems
Published By | Publication Date | Number of Pages |
IEEE | 2009 | 143 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C62.22-2009 Front Cover IEEE Std C62.22-2009 Front Cover |
3 | Title Page Title Page |
4 | Abstract/Keywords Abstract/Keywords |
6 | Introduction Introduction |
7 | Notice to users Notice to users Laws and regulations Laws and regulations Copyrights Copyrights Updating of IEEE documents Updating of IEEE documents Errata Errata Interpretations Interpretations Patents Patents |
8 | Participants Participants |
10 | Contents Contents |
13 | Important Notice Important Notice 1. Scope 1. Scope 2. Normative references 2. Normative references |
15 | 3. Definitions, acronyms, and abbreviations 3. Definitions, acronyms, and abbreviations 3.1 Definitions 3.1 Definitions |
19 | 3.2 Acronyms and abbreviations 3.2 Acronyms and abbreviations 4. General considerations 4. General considerations 4.1 Overvoltages 4.1 Overvoltages |
21 | 4.2 Metal-oxide arresters 4.2 Metal-oxide arresters |
27 | 4.3 Protective levels 4.3 Protective levels |
28 | 4.4 Insulation withstand 4.4 Insulation withstand 4.5 Separation effects 4.5 Separation effects 4.6 Insulation coordination 4.6 Insulation coordination |
29 | 5. Protection of transmission equipment and substations 5. Protection of transmission equipment and substations 5.1 Introduction 5.1 Introduction |
30 | 5.2 Transformer protection, step-by-step procedures 5.2 Transformer protection, step-by-step procedures |
52 | 5.3 Special considerations for protection of transformers 5.3 Special considerations for protection of transformers |
53 | 5.4 Protection of dry-type insulation 5.4 Protection of dry-type insulation 5.5 Special considerations for shunt capacitor bank applications 5.5 Special considerations for shunt capacitor bank applications |
55 | 5.6 Protection of underground transmission cables 5.6 Protection of underground transmission cables |
56 | 5.7 Protection of gas-insulated substations (GIS) 5.7 Protection of gas-insulated substations (GIS) |
57 | 5.8 Protection of high-power static devices and systems 5.8 Protection of high-power static devices and systems 5.9 Protection of series capacitor banks 5.9 Protection of series capacitor banks |
59 | 5.10 Protection of circuit breakers 5.10 Protection of circuit breakers |
62 | 6. Protection of distribution systems 6. Protection of distribution systems 6.1 Introduction 6.1 Introduction |
65 | 6.2 General procedure 6.2 General procedure |
66 | 6.3 Selection of arrester ratings 6.3 Selection of arrester ratings |
70 | 6.4 Distribution system overvoltages 6.4 Distribution system overvoltages |
75 | 6.5 Insulation coordination 6.5 Insulation coordination |
76 | 6.6 Arrester connections 6.6 Arrester connections |
79 | 6.7 Special applications 6.7 Special applications |
86 | 6.8 Isolation 6.8 Isolation 7. Protection of overhead lines 7. Protection of overhead lines |
87 | 7.1 General considerations 7.1 General considerations |
92 | 7.2 Transmission-line protection 7.2 Transmission-line protection |
94 | 7.3 Distribution-ine protection 7.3 Distribution-ine protection |
95 | 8. Protection of electrical machines, 1000 V and greater 8. Protection of electrical machines, 1000 V and greater |
97 | 8.1 Insulation withstand tests 8.1 Insulation withstand tests |
98 | 8.2 Methods of surge protection for motors started across the line (full voltage start) 8.2 Methods of surge protection for motors started across the line (full voltage start) |
99 | Annex A (informative) Lightning flashes, lightning stroke currents, traveling waves, and station shielding Annex A (informative) Lightning flashes, lightning stroke currents, traveling waves, and station shielding |
103 | Annex B (informative) COG for various conditions Annex B (informative) COG for various conditions |
107 | Annex C (informative) Calculations of surge arrester separation distances Annex C (informative) Calculations of surge arrester separation distances |
121 | Annex D (informative) Distribution system overvoltage line diagrams Annex D (informative) Distribution system overvoltage line diagrams |
123 | Annex E (informative) Dual transformer station Annex E (informative) Dual transformer station |
124 | Annex F (informative) Modeling of gapless metal-oxide surge arresters Annex F (informative) Modeling of gapless metal-oxide surge arresters |
127 | Annex G (informative) “Rules of thumb” for some common arrester energy discharge cases Annex G (informative) “Rules of thumb” for some common arrester energy discharge cases |
131 | Annex H (informative) Bibliography Annex H (informative) Bibliography |