IEEE C37.20.4 2013
$35.21
IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear
Published By | Publication Date | Number of Pages |
IEEE | 2013 | 45 |
Revision Standard – Active. Indoor ac medium-voltage switches for use in enclosures for application in power circuits at voltages above 1 kV through 38 kV are covered in this standard. Stationary or drawout, manual or power operation, and fused or unfused are included.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.20.4-2013 Front Cover |
3 | Title Page |
6 | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata |
7 | Patents |
8 | Participants |
10 | Introduction |
11 | Contents |
13 | Important Notice 1. Overview 1.1 Scope |
14 | 2. Normative references |
15 | 3. Definitions 4. Service conditions |
16 | 5. Ratings |
17 | 5.1 Rated maximum voltage (V) or (Ur) 5.2 Rated insulation level: (Ud) or (Up) |
18 | 5.3 Rated power frequency (fr) 5.4 Rated continuous (normal) current and temperature rise |
19 | 5.5 Rated short-time withstand current (Ik) |
20 | 5.6 Rated peak (formerly momentary) withstand current (Ip) 5.7 Rated duration of short circuit (tk) 5.8 Rated supply voltage of closing and opening devices and of auxiliary andcontrol circuits (Ua) 5.9 Rated supply frequency of closing and opening devices and of auxiliary circuits |
21 | 5.10 Rated pressure of compressed gas supply for insulation and/or operation 5.11 Rated filling levels for insulation and/or operation 5.12 Rated electrical operations 5.13 Rated mechanical operations 5.14 Rated load-switching current |
22 | 5.15 Rated fault-making current 5.16 Rated fault-making current for an integral switch and fuse 5.17 Rated cable-charging switching current (optional) 5.18 Rated unloaded transformer switching current (optional) 5.19 Rated direct-acting fuse-tripping current (optional) 6. Tests |
23 | 6.1 Grouping of tests |
24 | 6.2 Dielectric tests |
28 | 6.3 Radio influence voltage test 6.4 Measurement of the resistance of circuits 6.5 Temperature-rise tests |
30 | 6.6 Short-time withstand current and peak withstand current (formerly momentary)tests |
31 | 6.7 Verification of the degrees of protection provided by enclosures 6.8 Tightness tests 6.9 Electromagnetic compatibility tests 6.10 Additional tests on auxiliary and control circuits 6.11 X-Radiation procedure for vacuum interrupters |
32 | 6.12 Mechanical operations tests |
33 | 6.13 Fault-making test |
35 | 6.14 Load-switching current test 6.15 Cable-charging current switching test (optional) |
36 | 6.16 Unloaded-transformer switching test (optional) 6.17 Direct-acting fuse-tripping current test (optional) 6.18 Routine (production) |
37 | 6.19 Conformance test 6.20 Field dielectric tests |
38 | 7. Design and construction 7.1 Requirements for liquids in switchgear 7.2 Requirements gases in switchgear 7.3 Grounding of switch |
39 | 7.4 Auxiliary and control equipment 7.5 Dependent power operation 7.6 Stored energy operation 7.7 Independent manual operation 7.8 Operation of releases 7.9 Low- and high-pressure interlocking and monitoring devices 7.10 Nameplates |
40 | 7.11 Interlocking devices 7.12 Position indication |
41 | 7.13 Degrees of protection by enclosure 7.14 Creepage distance for outdoor insulators 7.15 Gas and vacuum tightness 7.16 Liquid tightness 7.17 Flammability 7.18 Electromagnetic compatibility 7.19 X-ray emissions 7.20 Primary connections |
42 | 7.21 Functional components 7.22 Securing the position 7.23 Auxiliary contacts for signaling, if provided |
43 | 8. Application guide 8.1 General 8.2 Voltage 8.3 Frequency 8.4 Continuous current 8.5 Short-circuit current 8.6 Cable-charging current 8.7 Unloaded transformer switching current capability |
44 | 8.8 Direct-acting fuse trip capabilities 8.9 Unusual service conditions 8.10 Maintenance |
45 | Annex A (informative) Bibliography |