IEEE 802.3at 2009
$58.50
IEEE Standard for Information technology– Local and metropolitan area networks– Specific requirements– Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 3: Data Terminal Equipment (DTE) Power via the Media Dependent Interface (MDI) Enhancements
Published By | Publication Date | Number of Pages |
IEEE | 2009 | 141 |
Amendment Standard – Inactive – Superseded. This amendment includes changes to IEEE Std 802.3-2008 to augment the capabilities of IEEE Std 802.3 with higher power levels and improved power management information.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 802.3at-2009 Front Cover |
3 | Title page |
6 | Introduction |
7 | Notice to users Laws and regulations Copyrights Updating of IEEE documents |
8 | Errata Downloads Interpretations Patents |
9 | Participants |
13 | CONTENTS |
19 | Important Notice |
20 | 1. Introduction 1.3 Normative references 1.4 Definitions |
21 | 25. Physical Medium Dependent (PMD) sublayer and baseband medium, type 100BASE-TX 25.4 Specific requirements and exceptions 25.4.4a Change to 9.1.7, “Worst case droop of transformer” 25.4.4a.1 Equivalent system time constant |
22 | 25.4.5a Addition to 10.1, “Receiver” |
23 | 25.5 Protocol implementation conformance statement (PICS) proforma for Clause 25, Physical Medium Dependent (PMD) sublayer and baseband medium, type 100BASE-TX 25.5.3 Major capabilities/options 25.5.3.1 DTE Power via MDI major capabilities/options 25.5.4 PICS proforma tables for the Physical Medium Dependent (PMD) sublayer and baseband medium, type 100BASE-TX 25.5.4.4 DTE Power via MDI compliance |
25 | 30. Management 30.2 Managed objects 30.2.2 Overview of managed objects 30.2.2.1 Text description of managed objects 30.2.3 Containment |
27 | 30.2.5 Capabilities |
31 | 30.9 Management for DTE Power via MDI Sourcing Equipment (PSE) |
32 | 30.9.2 PD managed object class 30.9.2.1 PD attributes 30.9.2.1.1 aPDID 30.12.2 LLDP Local System Group managed object class 30.12.2.1 LLDP Local System Group attributes 30.12.2.1.14 aLldpXdot3LocPowerType 30.12.2.1.15 aLldpXdot3LocPowerSource 30.12.2.1.16 aLldpXdot3LocPowerPriority |
33 | 30.12.2.1.17 aLldpXdot3LocPDRequestedPowerValue 30.12.2.1.18 aLldpXdot3LocPSEAllocatedPowerValue 30.12.2.1.19 aLldpXdot3LocResponseTime |
34 | 30.12.2.1.20 aLldpXdot3LocReady 30.12.2.1.21 aLldpXdot3LocReducedOperationPowerValue 30.12.3 LLDP Remote System Group managed object class 30.12.3.1 LLDP Remote System Group attributes 30.12.3.1.14 aLldpXdot3RemPowerType 30.12.3.1.15 aLldpXdot3RemPowerSource |
35 | 30.12.3.1.16 aLldpXdot3RemPowerPriority 30.12.3.1.17 aLldpXdot3RemPDRequestedPowerValue 30.12.3.1.18 aLldpXdot3RemPSEAllocatedPowerValue |
37 | 33. Data Terminal Equipment (DTE) Power via Media Dependent Interface (MDI) 33.1 Overview 33.1.1 Objectives |
38 | 33.1.2 Compatibility considerations 33.1.3 Relationship of DTE Power via MDI to the IEEE 802.3 Architecture |
39 | 33.1.4 Type 1 and Type 2 system parameters |
40 | 33.1.4.1 Type 2 cabling requirement 33.1.4.2 Type 1 and Type 2 channel requirement 33.2 Power sourcing equipment (PSE) 33.2.1 PSE location |
41 | 33.2.2 Midspan PSE types |
46 | 33.2.3 PI pin assignments |
47 | 33.2.4 PSE state diagrams 33.2.4.1 Overview 33.2.4.2 Conventions 33.2.4.3 Constants 33.2.4.4 Variables |
51 | 33.2.4.5 Timers 33.2.4.6 Functions |
53 | 33.2.4.7 State diagrams |
55 | 33.2.5 PSE detection of PDs 33.2.5.1 PSE detection validation circuit |
57 | 33.2.5.2 Detection probe requirements 33.2.5.3 Detection criteria |
58 | 33.2.5.4 Rejection criteria 33.2.5.5 Open circuit criteria 33.2.6 PSE classification of PDs and mutual identification |
60 | 33.2.6.1 PSE 1-Event Physical Layer classification |
61 | 33.2.6.2 PSE 2-Event Physical Layer classification |
63 | 33.2.7 Power supply output |
64 | 33.2.7.1 Output voltage in the POWER_ON state 33.2.7.2 Voltage transients |
65 | 33.2.7.3 Power feeding ripple and noise 33.2.7.4 Continuous output current capability in the POWER_ON state 33.2.7.5 Output current in POWER_UP mode |
66 | 33.2.7.6 Overload current 33.2.7.7 Output current—at short circuit condition |
68 | 33.2.7.8 Turn off time 33.2.7.9 Turn off voltage 33.2.7.10 Continuous output power capability in POWER_ON state 33.2.7.11 Current unbalance |
69 | 33.2.7.12 Power turn on time 33.2.7.13 PSE stability 33.2.8 Power supply allocation 33.2.9 PSE power removal 33.2.9.1 PSE Maintain Power Signature (MPS) requirements 33.2.9.1.1 PSE AC MPS component requirements |
70 | 33.2.9.1.2 PSE DC MPS component requirements |
71 | 33.3 Powered devices (PDs) 33.3.1 PD PI |
72 | 33.3.2 PD type descriptions 33.3.3 PD state diagram 33.3.3.1 Conventions |
73 | 33.3.3.2 Constants 33.3.3.3 Variables |
74 | 33.3.3.4 Timers |
75 | 33.3.3.5 State diagrams |
76 | 33.3.4 PD valid and non-valid detection signatures |
78 | 33.3.5 PD classifications 33.3.5.1 PD 1-Event class signature |
79 | 33.3.5.2 PD 2-Event class signature 33.3.5.2.1 Mark Event behavior 33.3.6 PSE Type identification |
80 | 33.3.7 PD power |
81 | 33.3.7.1 Input voltage 33.3.7.2 Input average power 33.3.7.2.1 System stability test conditions during startup and steady state operation |
82 | 33.3.7.3 Input inrush current 33.3.7.4 Peak operating power |
83 | 33.3.7.5 Peak transient current |
84 | 33.3.7.6 PD behavior during transients at the PSE PI 33.3.7.7 Ripple and noise |
85 | 33.3.7.8 PD classification stability time 33.3.7.9 Backfeed voltage 33.3.8 PD Maintain Power Signature 33.4 Additional electrical specifications |
86 | 33.4.1 Isolation 33.4.1.1 Electrical isolation environments 33.4.1.1.1 Environment A requirements 33.4.1.1.2 Environment B requirements |
87 | 33.4.2 Fault tolerance 33.4.3 Impedance balance |
88 | 33.4.4 Common-mode output voltage |
90 | 33.4.5 Pair-to-pair output noise voltage |
91 | 33.4.6 Differential noise voltage 33.4.7 Return loss 33.4.8 100BASE-TX transformer droop |
92 | 33.4.9 Midspan PSE device additional requirements |
94 | 33.4.9.1 “Connector” or “telecom outlet” Midspan PSE device transmission requirements 33.4.9.1.1 Near End Crosstalk (NEXT) 33.4.9.1.2 Insertion loss 33.4.9.1.3 Return loss |
95 | 33.4.9.1.4 Work area or equipment cable Midspan PSE 33.4.9.2 Midspan signal path requirements 33.4.9.2.1 Alternative A Midspan PSE signal path transfer function |
96 | 33.5 Management function requirements 33.5.1 PSE registers 33.5.1.1 PSE Control register (Register 11) (R/W) |
97 | 33.5.1.1.1 Reserved bits (11.15:6) 33.5.1.1.2 Data Link Layer Classification capability (11.5) 33.5.1.1.3 Enable Physical Layer classification (11.4) |
98 | 33.5.1.1.4 Pair Control (11.3:2) 33.5.1.1.5 PSE enable (11.1:0) 33.5.1.2 PSE Status register (Register 12) (R/W) |
99 | 33.5.1.2.1 PSE Type electrical parameters (12.15) 33.5.1.2.2 Data Link Layer Classification Enabled (12.14) |
100 | 33.5.1.2.3 Physical Layer Classification Supported (12.13) 33.5.1.2.4 Power Denied or Removed (12.12) 33.5.1.2.5 Valid Signature (12.11) 33.5.1.2.6 Invalid Signature (12.10) 33.5.1.2.7 Short Circuit (12.9) 33.5.1.2.8 Overload (12.8) 33.5.1.2.9 MPS Absent (12.7) |
101 | 33.5.1.2.10 PD Class (12.6:4) 33.5.1.2.11 PSE Status (12.3:1) 33.5.1.2.12 Pair Control Ability (12.0) 33.6 Data Link Layer classification 33.6.1 TLV frame definition 33.6.2 Data Link Layer classification timing requirements |
102 | 33.6.3 Power control state diagrams 33.6.3.1 Conventions 33.6.3.2 Constants |
103 | 33.6.3.3 Variables |
105 | 33.6.3.4 Functions |
106 | 33.6.3.5 State diagrams |
107 | 33.6.4 State change procedure across a link |
108 | 33.6.4.1 PSE state change procedure across a link 33.6.4.2 PD state change procedure across a link |
109 | 33.7 Environmental 33.7.1 General safety 33.7.2 Network safety 33.7.3 Installation and maintenance guidelines 33.7.4 Patch panel considerations 33.7.5 Telephony voltages |
110 | 33.7.6 Electromagnetic emissions 33.7.7 Temperature and humidity 33.7.8 Labeling |
111 | 33.8 Protocol implementation conformance statement (PICS) proforma for Clause 33, DTE Power via MDI 33.8.1 Introduction 33.8.2 Identification 33.8.2.1 Implementation identification 33.8.2.2 Protocol summary |
112 | 33.8.2.3 PD Major capabilities/options |
113 | 33.8.2.4 PSE Major capabilities/options |
114 | 33.8.3 PICS proforma tables for DTE Power via MDI 33.8.3.1 Common device features 33.8.3.2 Power sourcing equipment |
119 | 33.8.3.3 Powered devices |
122 | 33.8.3.4 Electrical specifications applicable to the PSE and PD |
123 | 33.8.3.5 Electrical specifications applicable to the PSE |
124 | 33.8.3.6 Electrical specifications applicable to the PD |
125 | 33.8.3.7 Management function requirements |
128 | 33.8.3.8 Data Link Layer classification requirements |
129 | 33.8.3.9 Environmental specifications applicable to PSEs and PDs 33.8.3.10 Environmental specifications applicable to the PSE |
131 | 79. IEEE 802.3 Organizationally Specific Link Layer Discovery Protocol (LLDP) type, length, and value (TLV) information elements 79.2 Requirements of the IEEE 802.3 Organizationally Specific TLV set 79.3 IEEE 802.3 Organizationally Specific TLVs 79.3.2 Power via MDI TLV |
132 | 79.3.2.4 Requested power type/source/priority 79.3.2.4.1 Power type 79.3.2.4.2 Power source |
133 | 79.3.2.4.3 Power priority 79.3.2.5 PD requested power value 79.3.2.6 PSE allocated power value |
134 | 79.4 IEEE 802.3 Organizationally Specific TLV selection management 79.4.2 IEEE 802.3 Organizationally Specific TLV/LLDP Local and Remote System group managed object class cross references |
136 | 79.5 Protocol implementation conformance statement (PICS) proforma for IEEE 802.3 Organizationally Specific Link Layer Discovery Protocol (LLDP) type, length, and values (TLV) information elements 79.5.6 Power via MDI TLV |
137 | Annex A (informative) Bibliography |
139 | Annex 33A (informative) PSE-PD stability 33A.1 Recommended PSE design guidelines and test setup |
141 | 33A.2 Recommended PD design guidelines |