FGI Guidelines 2001
$5.42
FGI Guidelines for Design and Construction of Hospital and Health Care Facilities
Published By | Publication Date | Number of Pages |
FGI | 2001 | 195 |
This is the 2001 edition of Guidelines for Design and Construction of Hospital and Health Care Facilities
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
3 | Copyright |
4 | CONTENTS |
7 | PREFACE |
11 | MAJOR ADDITIONS AND REVISIONS |
15 | ACKNOWLEDGMENTS |
18 | 1. Introduction 1.1 General |
19 | 1.2 Interpretations of Requirements 1.3 Renovation |
20 | 1.4 Design Standards for the Disabled |
21 | 1.5 Provisions for Disasters |
22 | 1.6 Codes and Standards |
27 | 2. Environment of Care 2.1 Energy and Other Resource Conservation |
28 | 3. Site 3.1 Location 3.2 Facility Site Design 3.3 Environmental Pollution Control |
30 | 4. Equipment 4.1 General 4.2 Classification |
31 | 4.3 Major Technical Equipment 4.4 Equipment Shown on Drawings 4.5 Electronic Equipment |
32 | 5. Construction 5.1 Planning and Design |
33 | 5.2 Phasing 5.3 Commissioning |
34 | 5.4 Nonconforming Conditions |
35 | 6. Record Drawings and Manuals 6.1 Drawings 6.2 Equipment Manuals 6.3 Design Data |
36 | 7. General Hospital 7.1 General Considerations 7.2 Nursing Unit (Medical and Surgical) |
41 | 7.3 Critical Care Units |
47 | 7.4 Nurseries |
48 | 7.5 Pediatric and Adolescent Unit |
49 | 7.6 Psychiatric Nursing Unit |
51 | 7.7 Surgical Suites |
56 | 7.8 Obstetrical Facilities |
59 | 7.9 Emergency Service |
63 | 7.10 Imaging Suite |
67 | 7.11 Nuclear Medicine |
70 | 7.12 Laboratory Suite |
71 | 7.13 Rehabilitation Therapy Department |
72 | 7.14 Renal Dialysis Unit (Acute and Chronic |
73 | 7.15 Respiratory Therapy Service |
74 | 7.16 Morgue 7.17 Pharmacy |
75 | 7.18 Dietary Facilities |
77 | 7.19 Administration and Public Areas 7.20 Medical Records 7.21 Central Services |
78 | 7.22 General Stores 7.23 Linen Services |
79 | 7.24 Facilities for Cleaning and Sanitizing Carts 7.25 Employee Facilities 7.26 Housekeeping Rooms 7.27 Engineering Service and Equipment Areas |
80 | 7.28 General Standards for Details and Finishes |
82 | 7.29 Design and Construction, including Fire-Resistant Standards |
83 | 7.30 Special Systems |
85 | 7.31 Mechanical Standards |
91 | 7.32 Electrical Standards |
94 | 7.33 Hyperbaric Suite |
101 | 8. Nursing Facilities 8.1 General Conditions |
102 | 8.2 Resident Unit |
105 | 8.3 Resident Support Areas 8.4 Activities |
106 | 8.5 Rehabilitation Therapy 8.6 Personal Services (Barber/Beauty) Areas 8.7 Subacute Care Facilities 8.8 Alzheimer’s and Other Dementia Units |
107 | 8.9 Dietary Facilities |
108 | 8.10 Administrative and Public Areas 8.11 Linen Services |
109 | 8.12 Housekeeping Rooms 8.13 Engineering Service and Equipment Areas 8.14 General Standards for Details and Finishes |
111 | 8.15 Finishes 8.16 Construction Features 8.17-8.29 Reserved 8.30 Special Systems |
112 | 8.31 Mechanical Standards |
115 | 8.32 Electrical Standards |
120 | 9. Outpatient Facilities 9.1 General |
121 | 9.2 Common Elements for Outpatient Facilities |
124 | 9.3 Primary Care Outpatient Centers |
125 | 9.4 Small Primary (Neighborhood) Outpatient Facility |
127 | 9.5 Outpatient Surgical Facility |
131 | 9.6 Freestanding Emergency Facility |
133 | 9.7 Freestanding Birthing Center |
135 | 9.8 Freestanding Outpatient Diagnostic and Treatment Facility 9.9 Endoscopy Suite |
136 | 9.10 Cough-Inducing and Aerosol- Generating Procedures 9.11-9.29 Reserved 9.30 Special Systems |
137 | 9.31 Mechanical Standards |
143 | 9.32 Electrical Standards |
145 | 10. Rehabilitation Facilities 10.1 General Considerations 10.2 Evaluation Unit |
146 | 10.3 Psychological Services Unit 10.4 Social Services Unit 10.5 Vocational Services Unit 10.6 Dining, Recreation, and Day Spaces 10.7 Dietary Department |
147 | 10.8 Personal Care Unit for Inpatients 10.9 Activities for Daily Living Unit 10.10 Administration and Public Areas |
148 | 10.11 Engineering Service and Equipment Areas 10.12 Linen Services 10.13 Housekeeping Room(s 10.14 Employee Facilities 10.15 Nursing Unit (for Inpatients |
150 | 10.16 Sterilizing Facilities 10.17 Physical Therapy Unit 10.18 Occupational Therapy Unit 10.19 Prosthetics and Orthotics Unit 10.20 Speech and Hearing Unit |
151 | 10.21 Dental Unit 10.22 Imaging Suite 10.23 Pharmacy Unit 10.24 Details and Finishes |
153 | 10.25 Design and Construction, including Fire-Resistant Standards 10.26-10.29 Reserved 10.30 Special Systems |
154 | 10.31 Mechanical Standards |
159 | 10.32 Electrical Standards |
161 | 11. Psychiatric Hospital 11.1 General Conditions 11.2 General Psychiatric Nursing Unit |
164 | 11.3 Child Psychiatric Unit 11.4 Geriatric, Alzheimer’s, and Other Dementia Unit 11.5 Forensic Psychiatric Unit 11.6 Radiology Suite 11.7 Nuclear Medicine |
165 | 11.8 Laboratory Suite 11.9 Rehabilitation Therapy Department |
166 | 11.10 Pharmacy 11.11 Dietary Facilities 11.12 Administration and Public Areas 11.13 Medical Records 11.14 Central Services |
167 | 11.15 General Storage 11.16 Linen Services 11.17 Facilities for Cleaning and Sanitizing Carts 11.18 Employee Facilities 11.19 Housekeeping Room 11.20 Engineering Service and Equipment Area 11.21 Waste Processing Services 11.22 General Standards for Details and Finishes 11.23 Design and Construction, including Fire-Resistant Standards 11.24-11.29 Reserved 11.30 Special Systems |
168 | 11.31 Mechanical Standards |
172 | 11.32 Electrical Standards |
175 | 12. Mobile, Transportable, and Relocatable Units 12.1 General |
177 | 12.2-12.30 Reserved 12.31 Mechanical Standards 12.32 Electrical Standards |
179 | 13. Hospice Care |
181 | 14. Assisted Living |
182 | 15. Adult Day Care Facilities |
183 | Glossary |
184 | Index |