BSI 23/30473669 DC 2023
$13.70
BS ISO/IEC 30129 AMD 2. Information technology. Telecommunications bonding networks for buildings and other structures
Published By | Publication Date | Number of Pages |
BSI | 2023 | 50 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | HORIZONTAL_STD FUNCTION_EMC FUNCTION_ENV FUNCTION_QUA FUNCTION_SAFETY |
4 | CONTENTS |
9 | Scope Normative references |
10 | Terms, definitions and abbreviations 3.1 Terms and definitions |
12 | 3.2 Abbreviations |
13 | Conformance |
14 | Overview of bonding networks |
15 | Selection of the telecommunications bonding network approach 6.1 Assessment of the impact of the telecommunications bonding network on the interconnection of telecommunications equipment |
17 | 6.2 Telecommunications bonding networks 6.3 Telecommunications bonding network performance 6.3.1 General 6.3.1.1 Protective bonding networks |
18 | 6.3.1.2 Dedicated telecommunications bonding networks 6.3.2 Requirements 6.3.2.1 General requirements 6.3.2.2 Protective bonding networks |
19 | 6.3.2.3 Dedicated bonding networks 6.3.3 DC resistance measurements 6.3.3.1 General |
20 | 6.3.3.2 Dedicated bonding networks Common features 7.1 General 7.2 Protective bonding networks 7.2.1 Protective bonding network conductors (PBNCs) 7.2.2 Main earthing terminal (MET) 7.3 Telecommunications entrance facility (TEF) |
21 | 7.4 Telecommunications bonding network components 7.4.1 Telecommunications bonding network conductors 7.4.1.1 Materials 7.4.1.2 Installation 7.4.2 Telecommunications bonding network connections |
22 | 7.5 Cabinets, frames and racks 7.5.1 External connections to a bonding network 7.5.1.1 Requirements 7.5.1.2 Recommendations |
23 | 7.5.2 Rack bonding conductors 7.5.2.1 Rack bonding conductors for d.c. resistance control 7.5.2.2 Rack bonding conductors (RBC) for impedance control 7.5.2.2.1 Requirements 7.5.2.2.2 Recommendations 7.5.3 Internal connections 7.5.3.1 Requirements OLE_LINK1 OLE_LINK2 |
24 | 7.5.3.2 Structural bonding within cabinets, frames and racks |
25 | 7.6 Miscellaneous bonding connections 7.6.1 General 7.6.2 Bonding conductors for d.c. resistance control 7.6.3 Bonding conductors for impedance control 7.6.3.1 Requirements 7.6.3.2 Recommendations 7.7 Documentation |
26 | Dedicated telecommunications bonding network 8.1 General |
27 | 8.2 Components 8.2.1 Primary bonding busbar (PBB) 8.2.2 Secondary bonding busbar (SBB) |
28 | 8.2.3 Bonding conductors for d.c. resistance control 8.2.3.1 Telecommunications bonding conductor (TBC) 8.2.3.2 Telecommunications bonding backbone (TBB) 8.2.3.2.1 Requirements 8.2.3.2.2 Recommendations |
29 | 8.2.3.3 Backbone bonding conductor (BBC) 8.2.4 Bonding conductors for impedance control 8.2.4.1 Telecommunications bonding backbone (TBB) 8.2.4.1.1 Requirements 8.2.4.1.2 Recommendations 8.2.4.2 Backbone bonding conductor (BBC) 8.2.4.2.1 Requirements 8.2.4.2.2 Recommendations 8.3 Implementation 8.3.1 Primary bonding busbar (PBB) 8.3.1.1 General |
30 | 8.3.1.2 Bonding to the PBB 8.3.2 Secondary bonding busbar (SBB) 8.3.2.1 General 8.3.2.2 Bonding to the secondary bonding busbar |
31 | 8.3.3 Telecommunications bonding conductor (TBC) 8.3.4 Telecommunications bonding backbone (TBB) |
32 | 8.3.5 Backbone bonding conductor (BBC) 8.3.6 Bonds to continuous conductive pathway systems 8.3.7 Bonds to structural metal Local telecommunications bonding networks in conjunction with protective bonding networks 9.1 Bonding for local distribution 9.1.1 Star protective bonding networks |
34 | 9.1.2 Ring protective bonding networks |
35 | 9.2 Telecommunications bonding conductors 9.2.1 Bonding conductors for d.c. resistance control 9.2.1.1 Requirements 9.2.1.2 Recommendations 9.2.2 Bonding conductors for impedance control 9.2.2.1 Requirements 9.2.2.2 Recommendations |
36 | 9.3 Bonding for areas of telecommunications equipment concentration Local telecommunications bonding networks in conjunction with dedicated telecommunications bonding networks 10.1 Bonding for areas of telecommunications equipment concentration 10.1.1 Requirements 10.1.2 Recommendations 10.1.3 Cabinets, frames and racks 10.2 Telecommunications equipment bonding conductors (TEBC) 10.2.1 TEBC for d.c. resistance control |
37 | 10.2.2 TEBC for impedance control 10.2.2.1 Requirements 10.2.2.2 Recommendations 10.2.3 Implementation Mesh bonded networks 11.1 General |
38 | 11.2 Mesh bonding alternatives 11.2.1 Local mesh bonding (MESH-IBN) networks 11.2.1.1 General |
39 | 11.2.1.2 Requirements |
40 | 11.2.1.3 Recommendations 11.2.2 MESH-BN 11.2.2.1 General 11.2.2.2 Requirements |
41 | 11.3 Bonding conductors of a mesh bonding network 11.3.1 Requirements 11.3.2 Recommendations 11.4 Bonding conductors to the mesh bonding network |
42 | 11.5 Supplementary bonding grid (SBG) 11.6 System reference potential plane (SRPP) 11.6.1 General |
43 | 11.6.2 Access floors 11.6.2.1 Requirements 11.6.2.2 Recommendations |
44 | 11.6.3 Transient suppression plate (TSP) |
45 | Annex A (normative)Maintenance of telecommunications bonding network performance A.1 General A.2 Periodic activity A.2.1 Schedule A.2.2 Implementation A.2.2.1 Protective bonding network A.2.2.2 Dedicated bonding network A.2.2.3 Assessment of results A.3 Causes of performance deterioration A.3.1 Galvanic corrosion |
46 | A.3.2 Requirements |
47 | Annex B (normative)Bonding conductor cross-sectional area |
48 | Annex C (infomative)Alternative terminology |
49 | Bibliography |