BS EN ISO 2746:2015

$102.76

Vitreous and porcelain enamels. High voltage test

Published By Publication Date Number of Pages
BSI 2015 18
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This International Standard describes two test methods of high voltage testing:

  • Test A is used to detect and locate defects in vitreous and porcelain enamels;

  • Test B is used to detect and locate defects and weak spots in vitreous and porcelain enamels.

The tests are performed using DC or pulsed DC high voltage.

The tests are applicable to dry surfaces of enamel coatings. In the case of moist surfaces, care should be taken to ensure that the locating of any defects is correctly performed.

Since test voltages depend on the coating thickness, the test method, especially with test A, may not be suitable for test specimens for which the coating thickness varies to a large extent.

PDF Catalog

PDF Pages PDF Title
6 Foreword
7 Introduction
9 1 Scope
2 Normative references
3 Terms and definitions
10 4 Principle
5 Apparatus
6 Specimens
11 7 Test voltage
7.1 Test A: Detection of defects (3.1) which extend down to the metal basis (e.g. open pores)
12 7.2 Test B: Detection of defects and weak spots (3.2)
8 Procedure
9 Test report
14 Bibliography
BS EN ISO 2746:2015