BS EN ISO 15181-1:2004
$102.76
Paints and varnishes. Determination of release rate of biocides from antifouling paints – General method for extraction of biocides
Published By | Publication Date | Number of Pages |
BSI | 2004 | 18 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | Paints and varnishes�— Determination of release rate of biocides from antifouling paints�— |
7 | Foreword |
8 | Introduction |
9 | Paints and varnishes�— Determination of release rate of biocides from antifouling paints�— 1��� Scope 2��� Normative references 3��� Principle |
10 | 4��� Required supplementary information 5��� Apparatus, equipment and reagents 5.1��� Test cylinder 5.2��� Rotating device 5.3��� Release rate measuring container |
11 | 5.4��� Holding tank 5.5��� Sample bottles 5.6��� Artificial seawater |
12 | 5.7��� Cleaning reagents 5.7.1��� Hydrochloric acid 5.7.2��� Hydrochloric acid 6��� Sampling 7��� Preparation of test cylinders 7.1��� Perform testing on three cylinders for each antifouling paint system. 7.2��� Clean the test cylinders ( 7.3��� Using masking tape, prepare an unmasked band on the exterior of the cylinder to the requir… 7.4��� Apply the antifouling paint system to the exterior circumferential surface of the test cyl… 7.5��� Carefully remove the masking tape without damaging the wet paint as soon as is practical. 7.6��� Dry and condition the cylinders at a temperature of 7.7��� Prepare one cylinder painted with the reference paint [see annex� 7.8��� Prepare one uncoated (no paint) cylinder as a reference blank as specified in 7.9��� If several paints are evaluated in the same series, at the same time and in the same holdi… |
13 | 8��� Procedure 8.1��� Clean all the apparatus by immersion in the concentrated hydrochloric acid ( 8.2��� Set up the holding tank ( 8.3��� Place the painted and reference cylinders (clause� 8.4��� At daily intervals, monitor the temperature and pH of the water, adjust using 8.5��� Every 7 days, monitor the salinity, and adjust as required (see 8.6��� On each test day (see 8.7��� After 1�day, 3�days, 7�days, 10�days, 14�days, 21�days, 24�days, 28�days, 31�days, 35�days… 8.8��� If testing beyond 45�days is specified, then perform the extraction method (see clause� 9��� Extraction method 9.1��� Prior to use, clean the release rate measuring containers ( 9.2��� Set up individual release rate measuring containers containing 9.3��� Remove each cylinder (including the references) from the holding tank and allow to drain f… 9.4��� After the defined period [see annex� 9.5��� Place an appropriate amount of water from the individual release rate measuring containers… |
14 | 10��� Test report |
15 | Required supplementary information |