Shopping Cart

No products in the cart.

BS EN ISO 105-B02:2014

$189.07

Textiles. Tests for colour fastness – Colour fastness to artificial light: Xenon arc fading lamp test

Published By Publication Date Number of Pages
BSI 2014 46
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of ISO 105 specifies a method intended for determining the effect on the colour of textiles of all kinds and in all forms to the action of an artificial light source representative of natural daylight (D65). The method is also applicable to white (bleached or optically brightened) textiles.

This method allows the use of two different sets of blue wool references. The results from the two different sets of references may not be identical.

PDF Catalog

PDF Pages PDF Title
4 Foreword
6 Foreword
7 Section sec_1
Section sec_2
Section sec_3
1 Scope
2 Normative references
3 Principle
8 Section sec_4
Section sec_4.1
Section sec_4.2
Section sec_4.3
Section sec_4.4
Section sec_4.5
Section sec_4.6
Section sec_4.7
Section sec_4.8
Section sec_4.9
4 Terms and definitions
9 Section sec_5
Section sec_5.1
Section sec_5.1.1
Section sec_5.1.2
Table tab_1
Section sec_5.1.3
Section sec_5.1.4
5 Materials and apparatus
5.1 Reference materials
10 Section sec_5.2
Section sec_5.2.1
Section sec_5.2.1.1
Section sec_5.2.1.2
Section sec_5.2.1.3
Section sec_5.2.1.4
Section sec_5.2.1.4.1
Section sec_5.2.1.4.2
Section sec_5.2.1.5
Section sec_5.2.1.5.1
Section sec_5.2.1.5.2
Section sec_5.2.1.5.3
Section sec_5.2.1.6
5.2 Laboratory exposure devices
11 Section sec_5.2.1.7
Section sec_5.2.1.8
Section sec_5.2.2
Section sec_5.2.3
Section sec_5.2.4
Section sec_5.2.5
Section sec_5.2.6
Section sec_5.2.7
Section sec_5.2.8
Section sec_5.2.9
Section sec_6
Section sec_6.1
Section sec_6.2
Section sec_6.3
6 Preparation of test specimens
12 Section sec_6.4
Section sec_6.5
Section sec_6.6
Section sec_7
7 Exposure conditions
13 Table tab_2
Section sec_8
Section sec_8.1
Section sec_8.1.1
Section sec_8.1.2
Section sec_8.1.3
Section sec_8.2
Section sec_8.2.1
8 Procedure
8.1 Apparatus set-up
8.2 Adjustment of the effective humidity (see Clause 7 and Annex E)
14 Figure fig_1
Section sec_8.2.2
Section sec_8.2.3
Section sec_8.2.4
Section sec_8.2.5
Section sec_8.2.6
Section sec_8.2.7
15 Section sec_8.3
Section sec_8.3.1
Section sec_8.3.2
Section sec_8.3.2.1
Section sec_8.3.2.2
Section sec_8.3.2.3
Section sec_8.3.2.4
Section sec_8.3.2.5
Section sec_8.3.2.6
8.3 Exposure methods
16 Section sec_8.3.2.7
Section sec_8.3.2.8
Section sec_8.3.2.9
Table tab_a
Figure fig_2
Section sec_8.3.3
Section sec_8.3.3.1
17 Section sec_8.3.3.2
Section sec_8.3.3.3
Section sec_8.3.3.4
Section sec_8.3.3.5
Section sec_8.3.3.6
Section sec_8.3.3.7
18 Table tab_b
Figure fig_3
Section sec_8.3.4
Section sec_8.3.4.1
Section sec_8.3.4.2
Section sec_8.3.4.3
19 Section sec_8.3.4.4
Section sec_8.3.4.5
Table tab_c
Figure fig_4
Section sec_8.3.5
Section sec_8.3.5.1
20 Section sec_8.3.5.2
Section sec_8.3.5.3
Section sec_8.3.5.4
Section sec_8.3.5.5
Section sec_8.3.6
Section sec_8.3.6.1
Section sec_8.3.6.2
21 Table tab_d
Figure fig_5
Section sec_8.3.6.3
Section sec_8.3.6.4
22 Table tab_e
Figure fig_6
Section sec_9
Section sec_9.1
Section sec_9.2
9 Assessment of colour fastness
23 Section sec_9.3
Section sec_9.4
Section sec_9.5
Section sec_9.6
Section sec_9.7
Section sec_9.8
Section sec_9.9
Section sec_10
10 Test report
26 Annex sec_A
Annex sec_A.1
Annex sec_A.2
Annex A
(normative)

Requirements for xenon arc exposure devices

27 Annex sec_A.3
28 Annex sec_A.4
29 Annex sec_B
Annex sec_B.1
Annex B
(normative)

Procedures for measuring the irradiance uniformity in the specimen exposure area (for apparatus manufacturers only)

30 Figure fig_B.1
Annex sec_B.2
Figure fig_B.2
Annex sec_B.3
31 Annex sec_C
Table tab_C.1
Annex C
(informative)

Light exposure equivalents for blue wool lightfastness references L2 to L9

32 Annex sec_D
Annex sec_D.1
Annex sec_D.2
Annex sec_D.3
Annex sec_D.4
Annex D
(informative)

General information on colour fastness to light

33 Annex sec_D.5
Annex sec_D.6
34 Annex sec_E
Annex sec_E.1
Annex sec_E.2
Annex sec_E.2.1
Annex sec_E.2.2
Annex sec_E.2.3
Annex E
(informative)

Guidelines for conducting testing

35 Annex sec_E.3
Annex sec_E.3.1
Annex sec_E.3.2
Annex sec_E.3.3
Annex sec_E.3.4
Annex sec_E.4
Annex sec_E.4.1
Annex sec_E.4.2
Annex sec_E.4.3
36 Annex sec_E.4.4
Annex sec_E.4.5
Annex sec_E.4.6
Annex sec_E.4.7
Annex sec_E.4.8
37 Annex sec_E.4.9
Annex sec_E.5
Annex sec_E.5.1
Annex sec_E.5.2
Annex sec_E.5.3
38 Table tab_g
Figure fig_E.1
Annex sec_E.6
Annex sec_E.6.1
Annex sec_E.6.2
Annex sec_E.6.3
39 Annex sec_E.6.4
Annex sec_E.6.5
40 Annex sec_E.7
Annex sec_E.7.1
Annex sec_E.7.2
Annex sec_E.8
Annex sec_E.8.1
Annex sec_E.8.2
41 Annex sec_E.8.3
Annex sec_E.8.4
Annex sec_E.8.5
Annex sec_E.8.6
42 Reference ref_1
Bibliography
BS EN ISO 105-B02:2014
$189.07