Shopping Cart

No products in the cart.

BS EN IEC 62790:2020

$198.66

Junction boxes for photovoltaic modules. Safety requirements and tests

Published By Publication Date Number of Pages
BSI 2020 62
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 62790:2020 is available as IEC 62790:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62790:2020 describes safety requirements, constructional requirements and tests for junction boxes up to 1 500 V DC for use on photovoltaic modules in accordance with class II of IEC 61140:2016. This document applies also to enclosures mounted on PV-modules containing electronic circuits for converting, controlling, monitoring or similar operations. Additional requirements concerning the relevant operations are applied under consideration of the environmental conditions of the PV-modules. This document does not apply to the electronic circuits of these devices, for which other IEC standards apply. This second edition cancels and replaces the first edition published in 2014. This edition includes the following significant technical changes with respect to the previous edition: – Modifications in normative references and terms and definitions; – Improvement of declaration of categories for junction boxes in 4.1; – Clarification for ambient temperature in 4.1; – Addition of requirement to provide information concerning RTE/RTI or TI in 4.2; – Reference to IEC 62930 instead of EN 50618 in 4.6; – Addition of “Functional insulation” in Table 1; – Addition of “Distance through cemented joints” in Table 3; – Correction of procedure of process to categorize material groups (deletion of PTI) in 4.15.2.3; – Requirement for approval of RTE/RTI or TI for insulation parts in 4.16.1 and 4.16.2; – Change of requirements concerning electrochemical potential in 4.17.2; – Clarification for IP-test in 5.3.4.2; – Addition of test voltage for cemented joints in 5.3.6 and 5.3.16; – Addition of detailled description on how to prepare the test sample for the thermal cycle test in 5.3.9.1; – New test procedure for bypass diode thermal test (5.3.18) in accordance with MQT 18.1 of IEC 61215-2:2016; – New test procedure for reverse overload current test in 5.3.23; – New Figure 1 for thermal cycle test.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
9 English
CONTENTS
12 FOREWORD
14 1 Scope
2 Normative references
16 3 Terms and definitions
20 4 Constructional requirements and performance
4.1 General
21 4.2 Marking and identification
4.2.1 Identification
4.2.2 Marking
22 4.2.3 Technical documentation
4.3 Protection against electric shock
4.4 Terminations, connecting devices and connection methods
23 4.5 Connectors
4.6 Cables
4.7 Resistance to ageing
4.8 General design
24 4.9 Degree of protection (IP)
4.10 Dielectric strength
4.11 Range of ambient temperature
4.12 Cable anchorage
4.13 Mechanical strength
25 4.14 Insulation
4.14.1 Type of insulation
4.14.2 Basic insulation
4.14.3 Supplementary insulation
4.14.4 Double insulation
4.14.5 Reinforced insulation
Tables
Table 1 – Required type of insulation
26 4.15 Clearances and creepage distances
4.15.1 Clearances
4.15.2 Creepage distances
Table 2 – Rated impulse voltages and minimum clearances
27 Table 3 – Creepage distances for basic insulation
28 4.16 Insulation parts
4.16.1 Outer accessible parts
4.16.2 Inner parts keeping active parts in position
4.17 Current carrying parts and resistance against corrosion
29 4.18 Sealing
4.19 Bypass-diode
4.20 Knock-out inlets (outlets) intended to be removed by mechanical impact
5 Tests
5.1 General
30 5.2 Preparation of specimens
Table 4 – Number of specimens
31 Table 5 – Values of torque for screw-type clamping units
32 5.3 Performance of tests
5.3.1 General
5.3.2 Durability of marking
5.3.3 Fixing of lid on rewirable junction box
5.3.4 Protection against electric shock
33 5.3.5 Measurement of clearances and creepage distances
5.3.6 Dielectric strength
5.3.7 Resistance to corrosion
5.3.8 Mechanical strength at lower temperatures
34 5.3.9 Thermal cycle test (IEC 60068-2-14:2009, Test Nb)
35 5.3.10 Damp heat test
5.3.11 Weather resistance test
5.3.12 Flammability class
36 5.3.13 Ball pressure test
5.3.14 Glow wire test
5.3.15 Resistance against ageing
5.3.16 Wet leakage current test
37 5.3.17 Humidity freeze test
5.3.18 Bypass diode thermal test
38 5.3.19 Test of terminations and connection methods
39 5.3.20 Knock-out inlets (outlets) intended to be removed by mechanical impact
5.3.21 Test of cord anchorage
40 Table 6 – Pull forces for cord anchorage
41 5.3.22 Retention on the mounting surface
5.3.23 Reverse current test at junction box
Table 7 – Values for torsion test
42 5.4 Test schedule
Table 8 – Marking, information, documentation, test group A
43 Table 9 – Material test, test group B (single tests)
44 Table 10 – Constructional requirements, test group C (single tests)
Table 11 – Mechanical tests, test group D (single tests)
45 Table 12 – Test sequence I, test group E (tests to be performed consecutively in this order)
Table 13 – Test sequence II, test group F (tests to be performed consecutively in this order)
46 Table 14 – Test sequence III, test group G (tests to be performed consecutively in this order)
Table 15 – Test sequence IV, test group H (tests to be performed consecutively in this order)
Table 16 – Reverse current test, test group I
47 Figures
Figure 1 – Thermal cycling test – Temperature and applied current profile
Table 17 – Test sequence V, test group J (tests to be performed consecutively in this order)
48 Figure 2 – Humidity-freeze cycle
Figure 3 – Typical arrangement for the cable anchorage pull test
49 Figure 4 – Typical arrangement for torsion test
Figure 5 – Typical arrangement for flammability test in accordance with 5.3.12.2
50 Figure 6 – Measurement of voltage drop
Figure 7 – Bypass diode thermal test
51 Figure 8 – Proper attachment of 5 N weight to junction box
52 Annex A (informative) Symbol “Do not disconnect under load”
Figure A.1 – Symbol “DO NOT DISCONNECT UNDER LOAD”
Figure A.2 – Symbol “DO NOT DISCONNECT UNDER LOAD” (IEC 60417-6070:2011-06)
53 Annex B (normative) Qualification of conformal coatings for protection against pollution
B.1 General
B.2 Technical properties
B.3 Qualification of coatings
54 Table B.1 – Test parameters, test conditions and test procedures
55 Table B.2 – Test sequence and conformity check (tests to be performed consecutively in this order)
56 Annex C (normative) Measurement of clearances and creepage distances
Table C.1 – Dimensions of X
59 Figure C.1 – Examples of methods of measuring clearances and creepage distances
60 Bibliography
BS EN IEC 62790:2020
$198.66