BS EN 61988-2-1:2012
$167.15
Plasma display panels – Measuring methods. Optical and optoelectrical
Published By | Publication Date | Number of Pages |
BSI | 2012 | 38 |
IEC 61988-2-1:2012 determines the following measuring methods for characterizing the performance of plasma display modules (PDP modules): a) four per cent (4 %) window luminance; b) luminance uniformity; c) dark-room contrast ratio; d) bright-room contrast ratio 100/70; e) white chromaticity and chromatic uniformity; f) colour gamut in the centre box; g) module power and current consumption; h) module power consumption using video signal; i) module luminous efficacy, and j) panel luminous efficacy. This edition includes the following significant technical changes with respect to the previous edition: The first edition of IEC 61988-2-1 and IEC 61988-2-2 were combined and reconstructed in this document.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
9 | 4 Structure of measuring equipment 5 Standard measuring conditions 5.1 Environmental conditions 5.2 Set-up conditions 5.2.1 General |
10 | 5.2.2 Measuring layout 5.2.3 Field frequency Figures Figure 1 – Measuring layout (side view) |
11 | 5.2.4 Adjustment of PDP modules 5.2.5 Warm-up condition of PDP modules 5.3 Lighting conditions 5.3.1 Dark-room conditions 5.3.2 Bright-room conditions |
12 | Figure 2 – Example of bright-room conditions |
13 | 6 Measuring methods 6.1 Measuring methods of 4 % window luminance 6.1.1 Purpose 6.1.2 Measuring equipment 6.1.3 Measurement Figure 3 – Four per cent (4 %) window luminance measuring pattern |
14 | 6.2 Measuring method of luminance uniformity 6.2.1 Purpose 6.2.2 Measuring equipment 6.2.3 Measurement |
15 | 6.3 Measuring method of dark-room contrast ratio 6.3.1 Purpose 6.3.2 Measuring equipment Figure 4 – Measuring points Tables Table 1 – Example of luminance uniformity measurement |
16 | 6.3.3 Measurement |
17 | 6.4 Measuring method of bright-room contrast ratio 100/70 6.4.1 General 6.4.2 Purpose 6.4.3 Measuring equipment 6.4.4 Measurement Figure 5 – Minimum luminance measuring pattern |
18 | 6.5 Measuring method of white chromaticity and chromatic uniformity 6.5.1 Purpose 6.5.2 Measuring equipment 6.5.3 Measurement |
19 | 6.6 Measuring method of colour gamut 6.6.1 Purpose 6.6.2 Measuring equipment 6.6.3 Measurement Table 2 – Example of chromaticity measurement |
20 | 6.7 Measuring method of module power and current consumption 6.7.1 Purpose 6.7.2 Measuring equipment Figure 6 – Example of the colour gamut measurement |
21 | 6.7.3 Measurement Figure 7 – Example of power and current measuring diagram |
22 | Table 3 – Example of power and current measurements (for a module that includes an AC input) Table 4 – Example of power and current measurement (for a module with DC inputs only) |
23 | 6.8 Measuring method of module power consumption using video signal 6.8.1 General 6.8.2 Measuring equipment 6.8.3 Applied digital video signal 6.8.4 Image processing board |
24 | 6.8.5 Measurement Table 5 – Example of measurement results of module power consumption using video signal |
25 | 6.9 Measuring method of module luminous efficacy 6.9.1 Purpose 6.9.2 Measuring equipment 6.9.3 Measurement |
26 | 6.10 Measuring method of panel luminous efficacy 6.10.1 Purpose 6.10.2 Measuring equipment |
27 | 6.10.3 Panel conditions Figure 8 – System diagram of sustain power measurement |
28 | 6.10.4 Driving waveform |
29 | 6.10.5 Applied display patterns 6.10.6 Measurement Figure 9 – Driving system and waveform |
33 | Annex A (informative) Clause cross-references from the previous edition of IEC 61988-2-1:2002 and IEC 61988-2-2:2003 to IEC 61988-2-1:2011 |
34 | Table A.1 – Clause cross-references |
35 | Bibliography |