Shopping Cart

No products in the cart.

BS EN 61970-452:2015

$215.11

Energy management system application program interface (EMS-API) – CIM model exchange specification

Published By Publication Date Number of Pages
BSI 2015 106
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61970 is a member of the IEC 61970‑450 to ‑499 series that, taken as a whole, defines at an abstract level the content and exchange mechanisms used for data transmitted between control centers and/or control center components.

The purpose of this document is to rigorously define the subset of classes, class attributes, and roles from the CIM necessary to execute state estimation and power flow applications. The North American Electric Reliability Council (NERC) Data Exchange Working Group (DEWG) Common Power System Modeling group (CPSM) produced the original data requirements, which are shown in Annex C. These requirements are based on prior industry practices for exchanging power system model data for use primarily in planning studies. However, the list of required data has been extended to facilitate a model exchange that includes parameters common to breaker-oriented applications. Where necessary this document establishes conventions, shown in Clause 5, with which an XML data file must comply in order to be considered valid for exchange of models.

This document is intended for two distinct audiences, data producers and data recipients, and may be read from two perspectives.

From the standpoint of model export software used by a data producer, the document describes a minimum subset of CIM classes, attributes, and associations which must be present in an XML formatted data file for model exchange. This standard does not dictate how the network is modelled, however. It only dictates what classes, attributes, and associations are to be used to describe the source model as it exists. All classes, attributes, and associations not explicitly labeled as recommended or conditionally required should be considered required with the following caveat. Consider, as an example, the situation in which an exporter produces an XML data file describing a small section of the exporter’s network that happens to contain no breakers. The resulting XML data file should, therefore, not contain an instance of the Breaker class. On the other hand, if the section of the exporter’s network does contain breakers, the resulting data file should contain instances of the Breaker class that include, at a minimum, the attributes and roles described herein for Breakers. Furthermore, it should be noted that an exporter may, at his or her discretion, produce an XML data file containing additional class data described by the CIM RDF Schema but not required by this document provided these data adhere to the conventions established in Clause 5.

From the standpoint of the model import used by a data recipient, the document describes a subset of the CIM that importing software must be able to interpret in order to import exported models. As mentioned above, data providers are free to exceed the minimum requirements described herein as long as their resulting data files are compliant with the CIM RDF Schema and the conventions established in Clause 5. The document, therefore, describes additional classes and class data that, although not required, exporters will, in all likelihood, choose to include in their data files. The additional classes and data are labeled as recommended or as not required to distinguish them from their required counterparts. Please note, however, that data importers could potentially receive data containing instances of any and all classes described by the CIM RDF Schema.

PDF Catalog

PDF Pages PDF Title
4 Foreword
Endorsement notice
5 Annex ZA (normative) Normative references to international publications with their corresponding European publications
6 CONTENTS
10 FOREWORD
13 INTRODUCTION
14 1 Scope
15 2 Normative references
3 Overview of data requirements
3.1 Overview
3.2 General requirements
16 3.3 Transformer modeling
Figures
Figure 1 – Two winding transformer impedance
17 3.4 Modeling authorities
Figure 2 – Three winding transformer impedance
18 3.5 Use of measurement classes
3.5.1 General
Tables
Table 1 – Valid measurementTypes
19 3.5.2 ICCP data exchange
3.6 Voltage or active power regulation
3.7 Use of curves
3.7.1 General
3.7.2 Generating unit reactive power limits
20 3.8 Definition of schedules
4 CIM Equipment Profile
4.1 CIM Equipment Profile General
4.2 Concrete Classes
4.2.1 Accumulator
Table 2 – Profiles defined in this document
21 4.2.2 AccumulatorValue
4.2.3 ACLineSegment
23 4.2.4 ActivePowerLimit
4.2.5 Analog
24 4.2.6 AnalogValue
4.2.7 ApparentPowerLimit
4.2.8 BaseVoltage
25 4.2.9 Bay
4.2.10 Breaker
4.2.11 BusbarSection
26 4.2.12 ConformLoad
4.2.13 ConformLoadGroup
27 4.2.14 ConformLoadSchedule
4.2.15 ConnectivityNode
28 4.2.16 ControlArea
4.2.17 ControlAreaGeneratingUnit
29 4.2.18 CurrentLimit
4.2.19 CurveData
30 4.2.20 DayType
4.2.21 Disconnector
4.2.22 Discrete
31 4.2.23 DiscreteValue
4.2.24 EnergyConsumer
32 4.2.25 EquivalentBranch
33 4.2.26 EquivalentInjection
34 4.2.27 EquivalentNetwork
4.2.28 EquivalentShunt
4.2.29 FossilFuel
35 4.2.30 GeneratingUnit
37 4.2.31 GeographicalRegion
4.2.32 GrossToNetActivePowerCurve
38 4.2.33 HydroGeneratingUnit
4.2.34 HydroPump
39 4.2.35 IEC61970CIMVersion
4.2.36 Line
4.2.37 LoadArea
40 4.2.38 LoadBreakSwitch
4.2.39 LoadResponseCharacteristic
42 4.2.40 MeasurementValueSource
4.2.41 MutualCoupling
43 4.2.42 Name
44 4.2.43 NameType
4.2.44 NonConformLoad
45 4.2.45 NonConformLoadGroup
4.2.46 NonConformLoadSchedule
46 4.2.47 NuclearGeneratingUnit
4.2.48 OperationalLimitSet
47 4.2.49 OperationalLimitType
4.2.50 PhaseTapChangerAsymetrical
48 4.2.51 PhaseTapChangerLinear
49 4.2.52 PhaseTapChangerSymetrical
50 4.2.53 PhaseTapChangerTabular
4.2.54 PhaseTapChangerTabularPoint
52 4.2.55 PowerTransformer
4.2.56 PowerTransformerEnd
54 4.2.57 RatioTapChanger
55 4.2.58 RatioTapChangerTabular
4.2.59 RatioTapChangerTabularPoint
56 4.2.60 ReactiveCapabilityCurve
57 4.2.61 RegularTimePoint
58 4.2.62 RegulatingControl
59 4.2.63 RegulationSchedule
60 4.2.64 Season
4.2.65 SeriesCompensator
4.2.66 ShuntCompensator
61 4.2.67 StaticVarCompensator
62 4.2.68 StationSupply
63 4.2.69 SubGeographicalRegion
4.2.70 SubLoadArea
4.2.71 Substation
64 4.2.72 Switch
4.2.73 SwitchSchedule
65 4.2.74 SynchronousMachine
67 4.2.75 TapChangerControl
4.2.76 TapSchedule
68 4.2.77 Terminal
4.2.78 ThermalGeneratingUnit
69 4.2.79 TieFlow
4.2.80 VoltageLevel
70 4.2.81 VoltageLimit
4.2.82 WindGeneratingUnit
71 4.3 Abstract Classes
4.3.1 BasicIntervalSchedule
4.3.2 ConductingEquipment
72 4.3.3 Conductor
4.3.4 ConnectivityNodeContainer
4.3.5 Curve
73 4.3.6 EnergyArea
4.3.7 Equipment
74 4.3.8 EquipmentContainer
4.3.9 EquivalentEquipment
4.3.10 IdentifiedObject
75 4.3.11 LoadGroup
4.3.12 Measurement
76 4.3.13 MeasurementValue
77 4.3.14 OperationalLimit
4.3.15 PhaseTapChanger
4.3.16 PhaseTapChangerNonLinear
78 4.3.17 PowerSystemResource
4.3.18 RegularIntervalSchedule
79 4.3.19 RegulatingCondEq
4.3.20 RotatingMachine
80 4.3.21 SeasonDayTypeSchedule
4.3.22 TapChanger
81 4.3.23 TransformerEnd
82 4.4 Enumerations
4.4.1 ControlAreaTypeKind
4.4.2 CurveStyle
83 4.4.3 FuelType
4.4.4 GeneratorControlSource
4.4.5 OperationalLimitDirectionKind
84 4.4.6 RegulatingControlModeKind
4.4.7 SeasonName
4.4.8 SVCControlMode
4.4.9 SynchronousMachineOperatingMode
85 4.4.10 SynchronousMachineType
4.4.11 TapChangerKind
4.4.12 TransformerControlMode
4.4.13 UnitSymbol
86 4.4.14 WindingConnection
4.5 Datatypes
4.5.1 ActivePower
4.5.2 AngleDegrees
4.5.3 ApparentPower
87 4.5.4 Conductance
4.5.5 CurrentFlow
4.5.6 Length
4.5.7 Money
4.5.8 PerCent
88 4.5.9 Reactance
4.5.10 ReactivePower
4.5.11 Resistance
4.5.12 Seconds
4.5.13 Susceptance
4.5.14 Voltage
89 4.5.15 VoltagePerReactivePower
5 Amplifications and conventions
5.1 Overview
5.2 XML file validity
5.3 Normative string tables
Table 3 – Valid attribute values
90 5.4 Roles and multiplicity
91 Annex A (informative) Model exchange use cases
Figure A.1 – Security coordinators
92 Figure A.2 – CIM model exchange
93 Figure A.3 – Revised CIM model exchange
94 Figure A.4 – Hierarchical modeling
95 Annex B (informative) Modeling authorities
97 Annex C (informative) Common power system model (CPSM) minimum data requirements
103 Bibliography
BS EN 61970-452:2015
$215.11