Refrigerated display scooping cabinets and pozzetto for gelato. Classification, requirements, performance and energy consumption testing

Published By Publication Date Number of Pages
BSI 2019 60
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies classification, requirements for the construction, performance and energy consumption testing of gelato scooping cabinets and pozzetto used to sale and/or display artisan and self made gelato. It specifies test conditions and methods for checking that the requirements have been satisfied, their marking and the list of their characteristics to be declared by the manufacturer.

PDF Catalog

PDF Pages PDF Title
2 National foreword
7 1 Scope
2 Normative references
3 Terms and definitions
8 4 Symbols and abbreviations
10 5 Requirements
5.1 Construction
5.1.1 General
5.1.1.1 Strength and rigidity
5.1.1.2 Pipes and connections
5.1.1.3 Condensate drainage
5.1.1.4 Joints and seams
5.1.2 Materials
11 5.1.3 Refrigerating system
5.1.3.1 Design and construction
5.1.3.2 Condensation
5.1.3.3 System protection
5.1.3.4 Refrigerant
5.1.4 Electrical components
5.1.5 Temperature display
5.1.5.1 General
12 5.1.5.2 Temperature-measuring instrument
5.1.5.3 Temperature sensor location
5.2 Operating characteristics
5.2.1 Absence of odour and taste
5.2.2 Classification according to temperature
14 5.2.3 Defrosting
15 5.2.4 Water vapour condensation
5.2.5 Energy consumption
5.2.6 Specific energy consumption
6 Test condition
6.1 General
6.2 Tests outside test room
17 6.3 Tests inside test room
6.3.1 General
6.3.2 Test room — General design, walls, floor and radiant heat
6.3.2.1 General
18 6.3.2.2 Test room (empty) — Thermal and air flow characteristics
6.3.2.3 Test room climate definition
26 6.3.3 Preparation and general test procedures for gelato scooping cabinet and pozzetto
6.3.3.1 Selection, installation and positioning within the test room of gelato scooping cabinet and pozzetto
29 6.3.3.2 Location of M-test gelato tubs
31 6.3.3.3 Running in
32 6.3.3.4 Stable conditions
6.3.3.5 Test period
6.3.3.6 Lighting
6.3.3.7 Accessories
6.3.3.8 Liquid refrigerant inlet condition
6.3.3.9 Power supply
6.3.3.10 Testing several gelato scooping cabinets and pozzetto in the same room
33 6.3.4 Temperature test
6.3.4.1 Test conditions
6.3.4.2 Covers and lids opening scheme
34 6.3.4.3 Temperature curves of M-test gelato tubs
35 6.3.4.4 Calculation of average mean temperature
36 6.3.4.5 Defrosting
6.3.5 Water vapour condensation test
6.3.5.1 Test conditions
37 6.3.5.2 Test results
6.3.5.3 Expression of results
38 6.3.6 Electrical energy consumption test
6.3.6.1 Test conditions
6.3.6.2 Gelato scooping cabinets and pozzetto fitted with incorporated condensing unit
6.3.6.3 Gelato scooping cabinets and pozzetto with remote condensing unit
6.3.7 Heat extraction rate measurement when condensing unit is remote from gelato scooping cabinet and pozzetto
6.3.7.1 Test conditions
39 6.3.7.2 Determination of heat extraction rate for gelato scooping cabinets and pozzetto intended for connection to compression-type refrigerating systems
41 6.3.7.3 Method
45 7 Test report
7.1 General
7.2 Tests outside test room
7.3 Tests inside test room
7.3.1 General test conditions
46 7.3.2 Gelato scooping cabinet and pozzetto preparation
47 7.3.3 Temperature test
48 7.3.4 Water vapour condensation test
7.3.5 Electrical energy consumption test
7.3.6 Heat extraction rate measurement when the condensing unit is remote from the gelato scooping cabinet and pozzetto
50 8 Marking
8.1 Marking plate
8.2 Information to be supplied by the manufacturer
52 Annex A (informative)Test for absence of odour and taste
A.1 Preparation and testing
A.1.1 Ambient temperature
A.1.2 Cleaning
A.1.3 Thermostat setting
A.1.4 Samples
A.1.5 Test period
53 A.2 Examination of samples
A.2.1 Conditions
A.2.2 Evaluation
54 Annex B (normative)Data requirements for performance and energy rating of gelato scooping cabinets and pozzetto
B.1 Scope
B.2 Terms and definitions
55 B.3 Data requirements for rating of gelato scooping cabinets and pozzetto with incorporated condensing unit
B.3.1 General
56 B.3.2 Evaluation of DEC
B.3.3 Evaluation of FEC
B.3.4 Evaluation of LEC
57 B.3.5 Evaluation of AEC
B.3.6 Evaluation of DFEC
B.3.7 Evaluation of PEC
B.3.8 Other electric energy consumption
B.3.9 Alternate components – Effect on DEC
B.4 Data requirements for rating of gelato scooping cabinets and pozzetto with remote condensing unit