Shopping Cart

No products in the cart.

BS EN 15199-4:2021

$167.15

Petroleum products. Determination of boiling range distribution by gas chromatography method – Light fractions of crude oil

Published By Publication Date Number of Pages
BSI 2021 36
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

This document specifies a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionization detection. This document is applicable to stabilized crude oils and for the boiling range distribution and the recovery up to and including n-nonane. A stabilized crude oil is defined as having a Reid Vapour Pressure equivalent to or less than 82,7 kPa as determined by IP 481 [3].

Annex C specifies an algorithm for merging the boiling point distribution results obtained using this method with the results obtained with EN 15199-3 . This will result in a boiling range distribution and recovery up to C120.

NOTE 1

There is no specific precision statement for the combined results obtained after merging the results of EN 15199?3 and EN 15199?4 . For the precision of the boiling range distribution up to n-nonane, the precision statement of EN 15199?4 applies. For the precision of the boiling range distribution from n-nonane through C120, the precision of EN 15199?3 applies.

NOTE 2

For the purposes of this document, the terms ā€œ% ( m/ m)ā€ and ā€œ% ( V/ V)ā€ are used to represent respectively the mass fraction, ?, and the volume fraction, ?.

WARNING

The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to take appropriate measures to ensure safety and health of personnel prior to application of the document and fulfil statutory and regulatory requirements for this purpose.

PDF Catalog

PDF Pages PDF Title
2 undefined
6 1 Scope
2 Normative references
3 Terms and definitions
7 4 Principle
5 Reagents and materials
6 Apparatus
6.1 Analytical balance capable of weighing to the nearest 0,1 mg
6.2 Gas chromatograph
8 6.3 Detector
9 6.4 Pre-column configurations
6.4.1 Heated valve switching box (see Figure B.1)
6.4.2 Injection port (see Figure B.2 and B.3)
6.5 Analytical column
6.5.1 General
6.5.2 Resolution
10 6.6 Skewness
6.7 Data collection
11 7 Sampling and sample handling
8 Calculation of response factors
12 9 Procedure
9.1 Sample preparation
9.2 Determination of backflush time
9.2.1 Initial work
9.2.2 Analytical column
9.2.3 Accelerated analytical column
13 9.3 Sample analysis
9.3.1 Initial work
9.3.2 Calculation of individual components results
14 9.3.3 Boiling point distribution of fraction up to and including nonane
10 Reporting
11 Precision
11.1 General
11.2 Repeatability, r
11.3 Reproducibility, R
15 12 Test report
16 Annex A (informative)Analysis assistance
23 Annex B (informative)Apparatus configuration
25 Annex C (normative)Algorithm for merging boiling point distribution results of EN 151993 and EN 151994
C.1 General
C.2 Summary of the procedure
C.3 EN 151993 and EN 151994 data accuracy determination
26 C.4 Elements required to perform merge of EN 151994 and EN 151993 at the merge point
C.4.1 General
C.4.2 EN 151994 mass percent by BP value array, N Elements
27 C.4.3 EN 151993 mass percent by BP data array, N elements
28 C.5 Data merging procedure
29 C.6 Reporting merged results
32 C.7 Normalizing results for recoveries in excess of 100 % by mass after merging
34 Blank Page
BS EN 15199-4:2021
$167.15