Shopping Cart

No products in the cart.

ASTM-D149:2004 Edition

$44.96

D149-97a(2004) Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies

Published By Publication Date Number of Pages
ASTM 2004 13
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM D149-97a-Reapproved2004

Historical Standard: Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies

ASTM D149

Scope

1.1 This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions.,

1.2 Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method may be used at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating may be a problem.

1.3 This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document should specify the particular options to be used (see ).

1.4 It may be used at various temperatures, and in any suitable gaseous or liquid surrounding medium.

1.5 This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test.

1.6 This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method D 3151).

1.7 This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It may also be used to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). With the addition of instructions modifying Section , this test method may be used for proof testing.

1.8 This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section . Also see .

Keywords

breakdown; breakdown voltage; calibration; criteria of breakdown; dielectric breakdown voltage; dielectric failure; dielectric strength; electrodes; flashover; power frequency; process-control testing; proof testing; quality-control testing; rapid rise; research testing; sampling; slow rate-of-rise; step-by-step; surrounding medium; voltage withstand

ICS Code

ICS Number Code 83.060 (Rubber)

DOI: 10.1520/D0149-97AR04

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Summary of Test Method
Significance and Use
Apparatus
3 TABLE 1
5 Hazards
Sampling
Test Specimens
6 Calibration
Conditioning
Procedure
FIG. 1
7 FIG. 2
FIG. 3
8 Calculation
Report
Precision and Bias
TABLE 2
9 Keywords
X1. SIGNIFICANCE OF THE DIELECTRIC STRENGTH TEST
X1.1 Introduction
X1.2 Postulated Mechanisms of Dielectric Breakdown
X1.3 Nature of Electrical Insulating Materials
X1.4 Influence of Test and Specimen Conditions
10 X1.5 Evaluation
11 X2. STANDARDS REFERRING TO TEST METHOD D149
X2.1 Introduction
12 TABLE X2.1
ASTM-D149
$44.96