Shopping Cart

No products in the cart.

AR PlumbingCode 2006

$41.71

Arkansas Plumbing Code

Published By Publication Date Number of Pages
AR 2006 150
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2006 International Plumbing Code

PDF Catalog

PDF Pages PDF Title
2 2006 ARKANSAS PLUMBING CODE
3 COPYRIGHT©
4 FOREWORD
6 TABLE OF CONTENTS
8 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
SECTION 103 DEPARTMENT OF HEALTH, ARKANSAS STATE PLUMBING AND NATURAL GAS SECTION
9 SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 APPROVAL
10 SECTION 106 PERMIT
11 SECTION 107 INSPECTIONS AND TESTING
12 SECTION 108 VIOLATIONS
13 SECTION 109 MEANS OF APPEAL
SECTION 110 CODE BOOK FEES
14 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
22 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
SECTION 302 EXCLUSION OF MATERIALS DETRIMENTALTO THE SEWER SYSTEM
SECTION 303 MATERIALS
SECTION 304 RODENTPROOFING
23 TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION
SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
24 SECTION 306 TRENCHING, EXCAVATION AND BACKFILL
SECTION 307 STRUCTURAL SAFETY
SECTION 308 PIPING SUPPORT
25 TABLE 308.5 HANGER SPACING
SECTION 309 FLOOD HAZARD RESISTANCE
26 SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS
SECTION 311 TOILET FACILITIES FOR WORKERS
SECTION 312 TESTS AND INSPECTIONS
27 SECTION 313 EQUIPMENT EFFICIENCIES
[M]SECTION 314 CONDENSATE DISPOSAL
30 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION 401 GENERAL
SECTION 402 FIXTURE MATERIALS
SECTION 403 MINIMUM PLUMBING FACILITIES
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.2 and 403.3)
31 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa(See Sections 403.2 and 403.3)
32 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
33 SECTION 404 ACCESSIBLE PLUMBING FACILITIES
SECTION 405 INSTALLATION OF FIXTURES
34 FIGURE 405.3.1 FIXTURE CLEARANCE
SECTION 406 AUTOMATIC CLOTHES WASHERS
SECTION 407 BATHTUBS
SECTION 408 BIDETS
35 SECTION 409 DISHWASHING MACHINES
SECTION 410 DRINKING FOUNTAINS
SECTION 411 EMERGENCY SHOWERS AND EYE WASH STATIONS
SECTION 412 FLOOR AND TRENCH DRAINS
SECTION 413 FOOD WASTE GRINDER UNITS
SECTION 414 GARBAGE CAN WASHERS
SECTION 415 LAUNDRY TRAYS
SECTION 416 LAVATORIES
36 SECTION 417 SHOWERS
37 SECTION 418 SINKS
SECTION 419 URINALS
SECTION 420 WATER CLOSETS
SECTION 421 WHIRLPOOL BATHTUBS
38 SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT
SECTION 423 SPECIALTY PLUMBING FIXTURES
SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS
39 SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 427 FLOOR SINKS
40 CHAPTER 5 WATER HEATERS
SECTION 501 GENERAL
SECTION 502 INSTALLATION
SECTION 503 CONNECTIONS
41 SECTION 504 SAFETY DEVICES
SECTION 505 INSULATION
42 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION
SECTION 601 GENERAL
SECTION 602 WATER REQUIRED
SECTION 603 WATER SERVICE
43 SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIAREQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBINGFIXTURES AND FIXTURE FITTINGS
44 TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
TABLE 604.10.1 MANIFOLD SIZING
SECTION 605 MATERIALS, JOINTS AND CONNECTIONS
45 TABLE 605.3 WATER SERVICE PIPE
46 TABLE 605.4 WATER DISTRIBUTION PIPE
TABLE 605.5 PIPE FITTINGS
47 TABLE 605.8 MANUFACTURED PIPE NIPPLES
49 SECTION 606 INSTALLATION OF THE BUILDINGWATER DISTRIBUTION SYSTEM
50 TABLE 606.5.4SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
TABLE 606.5.7SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION 607 HOT WATER SUPPLY SYSTEM
51 SECTION 608 PROTECTION OF POTABLE WATER SUPPLY
TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION
54 TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS
55 SECTION 609 HEALTH CARE PLUMBING
SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM
SECTION 611 DRINKING WATER TREATMENT UNITS
SECTION 612 SOLAR SYSTEMS
SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES
SECTION 614 TESTING AND REPAIR
57 CHAPTER 7 SANITARY DRAINAGE
SECTION 701 GENERAL
SECTION 702 MATERIALS
TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
58 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
59 TABLE 702.4 PIPE FITTINGS
SECTION 703 BUILDING SEWER
SECTION 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
SECTION 705 JOINTS
62 TABLE 705.20 CAULKING FERRULE SPECIFICATIONS
TABLE 705.21 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
63 TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
SECTION 708 CLEANOUTS
64 SECTION 709 FIXTURE UNITS
TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
SECTION 710 DRAINAGE SYSTEM SIZING
SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
65 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
66 TABLE 710.1(1)BUILDING DRAINS AND SEWERS
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa
67 SECTION 712 SUMPS AND EJECTORS
68 TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
SECTION 713 HEALTH CARE PLUMBING
69 TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS (Number of Connections of Various SizesPermitted to Various-sized Sterilizer Vent Stacks)
TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS (Number of Connections of Various Sizes Permitted To Various-sized Vent Stacks)
SECTION 714 DELETED
SECTION 715 BACKWATER VALVES
71 CHAPTER 8 INDIRECT/SPECIAL WASTE
SECTION 801 GENERAL
SECTION 802 INDIRECT WASTES
72 SECTION 803 SPECIAL WASTES
SECTION 804 MATERIALS, JOINTS AND CONNECTIONS
73 CHAPTER 9 VENTS
SECTION 901GENERAL
SECTION 902 MATERIALS
SECTION 903 VENT STACKS AND STACK VENTS
SECTION 904 VENT TERMINALS
74 SECTION 905 VENT CONNECTIONS AND GRADES
SECTION 906 FIXTURE VENTS
TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
SECTION 907 INDIVIDUAL VENT
SECTION 908 COMMON VENT
TABLE 908.3 COMMON VENT SIZES
SECTION 909 WET VENTING
75 TABLE 909.3 WET VENT SIZE
SECTION 910 WASTE STACK VENT
TABLE 910.4 WASTE STACK VENT SIZE
SECTION 911 CIRCUIT VENTING
76 SECTION 912 COMBINATION DRAIN AND VENT SYSTEM
SECTION 913 ISLAND FIXTURE VENTING
SECTION 914 RELIEF VENTS—STACKS OF MORE THAN10 BRANCH INTERVALS
SECTION 915 VENTS FOR STACK OFFSETS
77 SECTION 916 VENT PIPE SIZING
TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
78 TABLE 916.1—continued SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
TABLE 916.5.1SIZE AND LENGTH OF SUMP VENTS
79 SECTION 917 AIR ADMITTANCE VALVES
SECTION 918 DELETED
81 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION 1001 GENERAL
SECTION 1002 TRAP REQUIREMENTS
SECTION 1003 INTERCEPTORS AND SEPARATORS
82 TABLE 1003.3.4.1 CAPACITY OF GREASE TRAPS
83 SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS
85 CHAPTER 11 STORM DRAINAGE
SECTION 1101 GENERAL
SECTION 1102 MATERIAL
TABLE 1102.4 BUILDING STORM SEWER PIPE
TABLE 1102.5 SUBSOIL DRAIN PIPE
86 TABLE 1102.7 PIPE FITTINGS
SECTION 1103 TRAPS
SECTION 1104 CONDUCTORS AND CONNECTIONS
SECTION 1105 ROOF DRAINS
SECTION 1106 SIZE OF CONDUCTORS, LEADERSAND STORM DRAINS
87 FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
88 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
89 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
90 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
91 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWA
92 TABLE 1106.2 SIZE OF VERTICAL CONDUCTORS AND LEADERS
TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING
93 SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS
TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS
94 SECTION 1108 COMBINED SANITARY AND STORM SYSTEM
SECTION 1109 VALUES FOR CONTINUOUS FLOW
SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
SECTION 1111 SUBSOIL DRAINS
SECTION 1112 BUILDING SUBDRAINS
SECTION 1113 SUMPS AND PUMPING SYSTEMS
95 CHAPTER 12 REFERENCED STANDARDS
ANSI
ARI
ASME
96 ASSE
97 ASTM
100 AWS
AWWA
CISPI
CSA
101 ICC
102 ISEA
NFPA
NSF
PDI
UL
103 APPENDIX A PLUMBING PERMIT FEE SCHEDULE
PERMIT ISSUANCE
UNIT FEE SCHEDULE
OTHER INSPECTIONS AND FEES
105 APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES
107 APPENDIX C GRAY WATER RECYCLING SYSTEMS
SECTION C101 GENERAL
SECTION C102 SYSTEMS FOR FLUSHING WATERCLOSETS AND URINALS
108 SECTION C103 DELETED
FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS
109 APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES
TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
110 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
111 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
112 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
113 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
115 APPENDIX E SIZING OF WATER PIPING SYSTEM
SECTION E101 GENERAL
SECTION E102 INFORMATION REQUIRED
SECTION E103 SELECTION OF PIPE SIZE
119 TABLE E.1
TABLE E.2
120 FIGURE E103.3(1)EXAMPLE-SIZING
121 TABLE E103.3(1)RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
122 TABLE E103.3(2)LOAD VALUES ASSIGNED TO FIXTURESa
123 TABLE E103.3(3)TABLE FOR ESTIMATING DEMAND
124 TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
125 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
126 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING)
127 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING)
128 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING)
129 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
130 FIGURE E103.3(6 ) FRICTION LOSS IN FAIRLY ROUGH PIPEa
131 FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPEa
132 SECTION E201 SELECTION OF PIPE SIZE
133 TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPINGBASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
134 TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPINGBASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u
135 APPENDIX F DELETED
137 APPENDIX G VACUUM DRAINAGE SYSTEM
SECTION G101 VACUUM DRAINAGE SYSTEM
139 APPENDIX H RULES AND REGULATIONS PERTAINING TO PLUMBING AND/ORNATURAL GAS INSPECTOR CERTIFICATION
SECTION I AUTHORITY
SECTION II PURPOSE
SECTION III DEFINITIONS
SECTION IV ELIGIBILITY FOR CERTIFICATION
SECTION V QUALIFICATIONS
SECTION V IEXAMINATIONS
SECTION VII TERMS OF CERTIFICATION AND RENEWALS
SECTION VIII REVOCATION OF LICENSE
140 SECTION IX HEARINGS
SECTION X SEVERABILITY
SECTION XI REPEAL
141 APPENDIX I RULES AND REGULATIONS PERTAINING TO AIR ADMITTANCE VALVES (AAV) FOR D.W.V. VENTING SYSTEMS
143 INDEX
AR PlumbingCode 2006
$41.71