AAMI 8638 2010 RA 2015

$93.55

ANSI/AAMI/ ISO 8638:2010/(R)2015 – Cardiovascular implants and extracorporeal systems-Extracorporeal blood circuit for hemodialyzers, hemodiafilters and hemofilters

Published By Publication Date Number of Pages
AAMI 2010 26
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Specifies requirements for the single-use extracorporeal blood circuit and (integral and nonintegral) transducer protectors which are intended for use in hemodialysis, hemodiafiltration and hemofiltration.

PDF Catalog

PDF Pages PDF Title
1 ANSI/AAMI/ISO 8638:2010/(R)2015, Cardiovascular implants and extracorporeal systems — Extracorporeal blood circuit for hemodialyzers, hemodiafilters and hemofilters
2 Objectives and uses of AAMI standards and recommended practices
3 Title page
4 AAMI Standard
Copyright information
5 Contents
6 Glossary of equivalent standards
8 Committee representation
9 Background of ANSI/AAMI adoption of ISO 8638:2010
10 Foreword
11 Introduction
13 1 Scope
2 Normative references
14 3 Terms and definitions
15 4 Requirements
4.1 Biological safety
4.2 Sterility
4.3 Nonpyrogenicity
4.4 Mechanical characteristics
4.4.1 Structural integrity
4.4.2 Connectors to hemodialyzer, hemodiafilter or hemofilter
4.4.3 Connectors to vascular access device
4.4.4 Connectors to ancillary components
16 4.4.5 Color coding
4.4.6 Access ports
4.4.6.1 Needle access ports
4.4.6.2 Needleless access ports
17 4.4.7 Blood pathway volume
4.4.8 Air-capture chamber fill level
4.4.9 Transducer protectors
4.4.9.1 Integral transducer protectors
4.4.9.2 Non-integral transducer protectors
4.4.10 Blood pathway flow dynamics
4.4.11 Pump segment performance
4.5 Expiry date
18 4.6 Tubing compliance
5 Test methods
5.1 General
5.2 Biological safety
5.3 Sterility
5.4 Nonpyrogenicity
19 5.5 Mechanical characteristics
5.5.1 Structural integrity
5.5.1.1 Positive pressure
5.5.1.2 Negative pressure
5.5.2 Connectors to hemodialyzer, hemodiafilter or hemofilter
5.5.3 Connector to vascular access device
5.5.4 Connectors to ancillary components
5.5.5 Color coding
20 5.5.6 Access ports
5.5.6.1 Needle access ports
21 5.5.6.2 Needleless access ports
5.5.7 Blood pathway volume
5.5.8 Air-capture chamber fill level
5.5.9 Transducer protectors
5.5.10 Blood pathway flow dynamics
22 5.5.11 Pump segment performance
23 5.6 Expiry date
5.7 Tubing compliance
6 Labeling
6.1 Labeling on the device
6.2 Labeling on the unit container
24 6.3 Labeling on the outer container
6.4 Accompanying documentation
26 Bibliography