{"id":374274,"date":"2024-10-20T02:37:50","date_gmt":"2024-10-20T02:37:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-usermanual-62-1-2019\/"},"modified":"2024-10-26T04:35:33","modified_gmt":"2024-10-26T04:35:33","slug":"ashrae-usermanual-62-1-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-usermanual-62-1-2019\/","title":{"rendered":"ASHRAE UserManual 62.1 2019"},"content":{"rendered":"
This companion guide provides detailed information on the requirements of ANSI\/ASHRAE Standard 62.1-2019 and includes tables, illustrations, and examples to aid users in designing, installing, and operating systems for ventilation in buildings. Standard 62.1 User\u2019s Manual does not reproduce the requirements of the standard but rather paraphrases and elaborates upon them. Intended to be used in conjunction with the standard, this manual provides: \u2022 Information on the intent and application of Standard 62.1 \u2022 Sample calculations and examples \u2022 Best practices for applying the principles of good indoor air quality (IAQ) and effective ventilation when designing buildings and building systems \u2022 Useful reference material \u2022 Guidance for building operations and maintenance personnel \u2022 Instructions for the user in the application of tools used for compliance with ANSI\/ASHRAE Standard 62.1-2019 Also included is an exclusive link to the recently revised Web-based spreadsheets that aid in ventilation rate procedure calculations. This manual is intended for architects, engineers, manufacturers, plan examiners, field inspectors, general and specialty contractors, and operation and maintenance personnel. Standard 62.1 User\u2019s Manual is a crucial supplement for professionals concerned with ventilation and indoor air quality. Use it alongside your copy of ANSI\/ASHRAE Standard 62.1-2019.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Standard 62.1 User’s Manual <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Figures Tables <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Examples <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Preface General Information Audience Addenda Official Interpretations <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Standard 62.1 Organization <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Organization and Use of the User\u2019s Manual Data and Analysis Tools <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Acknowledgments <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 1 Purpose Overview (\u00a71.1) Regulatory Application (\u00a71.2) Existing Buildings (\u00a71.3) <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 2 Scope Spaces Covered (\u00a72.1) Scope of Requirements (\u00a72.2) Issues Covered (\u00a72.3) Laboratories, Healthcare, and Smoking Spaces (\u00a72.4) <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 3 Definitions, Abbreviations, and Acronyms Definitions Abbreviations and Acronyms <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 4 Outdoor Air Quality Overview Regional Air Quality (\u00a74.1) <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Local Air Quality (\u00a74.2) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Documentation (\u00a74.3) Regional Air Quality Compliance Local Air Quality Survey Information <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Summary <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5 Systems and Equipment Overview Ventilation Air Distribution (\u00a75.1) Designing for Air Balancing (\u00a75.1.1) <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Designing for Varying Loads and Operating Conditions (\u00a75.1.1.1) Plenum Systems (\u00a75.1.2) <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Documentation (\u00a75.1.3) Exhaust Duct Location (\u00a75.2) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Ventilation System Controls (\u00a75.3) Constant-Volume, Single-Zone Systems <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Variable-Air-Volume System <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Airstream Surfaces (\u00a75.4) Resistance to Mold Growth (\u00a75.4.1) Resistance to Erosion (\u00a75.4.2) <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Outdoor Air Intakes (\u00a75.5) Location (\u00a75.5.1) <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Rain Entrainment and Intrusion (\u00a75.5.2 and \u00a75.5.3) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Snow Entrainment (\u00a75.5.4) <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Bird Screens (\u00a75.5.5) Local Capture of Contaminants (\u00a75.6) Ozone Generating Devices (\u00a75.7) <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Combustion Air (\u00a75.8) Particulate Matter Removal (\u00a75.9) Maximum Indoor Air Dew Point in Mechanically Cooled Buildings (\u00a75.10) <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Building Exfiltration (\u00a75.11) Exception to the Exfiltration Requirement <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Drain Pans (\u00a75.12) Drain-Pan Slope (\u00a75.12.1) <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Drain Outlet (\u00a75.12.2) Drain Seal (\u00a75.12.3) Pan Size (\u00a75.12.4) <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Finned-Tube Coils and Heat Exchangers (\u00a75.13) Drain Pans (\u00a75.13.1) <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Finned-Tube-Coil Selection for Cleaning (\u00a75.13.2) <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Humidifiers and Water Spray Systems (\u00a75.14) Water Quality (\u00a75.14.1) Obstructions (\u00a75.14.2) <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Access for Inspection, Cleaning, and Maintenance (\u00a75.15) Equipment Clearance (\u00a75.15.1) Ventilation Equipment Access (\u00a75.15.2) <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Air Distribution System (\u00a75.15.3) Building Envelope and Interior Surfaces (\u00a75.16) <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Building Envelope (\u00a75.16.1) Weather Barrier Vapor Retarder Caulking and Sealing <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Soil Gases Condensation on Interior Surfaces (\u00a75.16.2) Buildings with Attached Parking Garages (\u00a75.17) <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Air Classification and Recirculation (\u00a75.18) Classification (\u00a75.18.1) Redesignation (\u00a75.18.2) <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Air Cleaning (\u00a75.18.2.1) Transfer (\u00a75.18.2.2) <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Recirculation Limitations (\u00a75.18.3) Documentation (\u00a75.18.4) <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | ETS Areas and ETS-Free Areas (\u00a75.19) <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Classification (\u00a75.19.1) Engineering Analysis Pressure Differential Measurement Airflow Measurement <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Pressure Exception for Dwelling Units and Adjacent Properties <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Pressure Exception for Hazardous Materials <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Physical Separation (\u00a75.19.3) <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | Transfer Air (\u00a75.19.4) Recirculation Prohibition (\u00a75.19.5) <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Exhaust Systems (\u00a75.19.6) Signage (\u00a75.19.7) <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | Reclassification (\u00a75.19.8) <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 6 Procedures General (\u00a76.1) <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Outdoor Air Treatment (\u00a76.1.4) Particulate Matter (\u00a76.1.4.1 and \u00a76.1.4.2) <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | Ozone (\u00a76.1.4.3) <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | Other Outdoor Contaminants (\u00a76.1.4.4) <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Ventilation Rate Procedure (\u00a76.2) Rationale for Ventilation Rate Procedure Two Component Approach and Additivity <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Determining Component Ventilation Rates <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Ventilation Efficiency <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | VRP Summary Zone Calculations (\u00a76.2.1) <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Determine Occupant and Building Rate Requirements (Rp and Ra) (\u00a76.2.1.1) Additional Requirements and Exceptions (\u00a76.2.1.1.2 through \u00a76.2.1.1.6) <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Estimate the Number of Occupants in the Zone (Pz) (\u00a76.2.1.1.7) <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Calculate the Net Occupiable Floor Area (Az) Calculate the Outdoor Air Required in the Breathing Zone (Vbz) Determine the Zone Air Distribution Effectiveness (Ez) (\u00a76.2.1.2) Calculate the Minimum Zone Outdoor Air Rate Required at the Supply Air Outlets (Voz) (\u00a76.2.1.3) <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | System Calculations Single-Zone Systems (\u00a76.2.2) 100% Outdoor Air Systems (\u00a76.2.3) Multiple-Zone Recirculating Systems (\u00a76.2.4) <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Determine Uncorrected Outdoor Airflow (Vou) (\u00a76.2.4.1) Determine System Ventilation Efficiency (Ev) (\u00a76.2.4.2) <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Calculate System Outdoor Air Intake (Vot) (\u00a76.2.4.4) <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Designing for Varying Operating Conditions (\u00a76.2.5) Variable Load Conditions (\u00a76.2.5.1) Short-Term Conditions (\u00a76.2.5.2) <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | Dynamic Reset (\u00a76.2.6) Demand Control Ventilation (DCV) (\u00a76.2.6.1) <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | Ventilation Efficiency (\u00a76.2.6.2) Outdoor Air Fraction (\u00a76.2.6.3) <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | Indoor Air Quality (IAQ) Procedure (\u00a76.3) <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | Compliance Requirements <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | Contaminant Sources (\u00a76.3.1) <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | Contaminant Concentration (\u00a76.3.2) Perceived Indoor Air Quality (\u00a76.3.3) <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | Design Approach (\u00a76.3.4) <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | Combined IAQ Procedure and Ventilation Rate Procedure (\u00a76.3.5) Documentation (\u00a76.3.6) <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | Natural Ventilation Procedure (\u00a76.4) <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | Prescriptive Compliance Path (\u00a76.4.1) <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | Engineered System Compliance Path (\u00a76.4.2) <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | Exhaust Ventilation (\u00a76.5) Prescriptive Compliance Path (\u00a76.5.1) Performance Compliance Path (\u00a76.5.2) <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | Design Documentation Procedures (\u00a76.6) <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | 7 Construction and System Start-Up General Construction Phase (\u00a77.1) Filters (\u00a77.1.2) Protection of Materials (\u00a77.1.3) <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | Protection of Occupied Areas (\u00a77.1.4) Air Duct System Construction (\u00a77.1.5) <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | System Start-Up (\u00a77.2) Application (\u00a77.2.1) New Air Handler Limited Alterations Air Balancing (\u00a77.2.2) <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | Testing of Drain Pans (\u00a77.2.3) <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | Cleanliness (\u00a77.2.4) Testing of Outdoor Air Dampers (\u00a77.2.5) System Documentation (\u00a77.2.6) <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | 8 Operations and Maintenance General (\u00a78.1) Application (\u00a78.1.1) <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | Building Alterations or Change of Use (\u00a78.1.2) <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | Operations and Maintenance Manual (\u00a78.2) <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | Ventilation System Operation (\u00a78.3) Ventilation System Maintenance (\u00a78.4) <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | Water Intrusion (Table 8-1, item a) <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | Appendix A Dynamic Ventilation Reset Control Overview Demand Control Ventilation (DCV) Fundamentals of CO2-Based DCV <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | Steady-State Assumption Control of Single-Zone Systems with Airflow Measurement Breathing Zone Parameters (Rp, Pz, Ra, Az) Zone Air Distribution Effectiveness (Ez) Activity Level Indoor Concentration Outdoor CO2 Concentration <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | Single-Zone DCV Control Sequence Control of Constant-Volume Systems without Airflow Measurement <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | Control of Multiple-Zone Systems CO2-based Dynamic Reset (CO2-based DR) Control Sequence <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | Outdoor Air Fraction\/Ventilation Efficiency-Based Dynamic Reset Zone Controls <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | Air-Handler Controls <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASHRAE Standard 62.1 User’s Manual–Based on ANSI\/ASHRAE Standard 62.1-2019, Ventilation for Acceptable Indoor Air Quality<\/b><\/p>\n |