{"id":341424,"date":"2024-10-19T23:56:21","date_gmt":"2024-10-19T23:56:21","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-tr-19263-12017\/"},"modified":"2024-10-25T23:08:32","modified_gmt":"2024-10-25T23:08:32","slug":"bsi-pd-iso-tr-19263-12017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-tr-19263-12017\/","title":{"rendered":"BSI PD ISO\/TR 19263-1:2017"},"content":{"rendered":"
This document specifies how to perform quality analysis of imaging systems (e.g. flatbed scanners, planetary scanners, or digital still cameras) used for digitization of reflective two-dimensional originals.<\/p>\n
Original materials include but are not limited to books, textual documents, drawings, prints, photographs, and paintings. Certain types of two-dimensional materials with complex surface geometry and or highly reflective surface elements require special illumination techniques that can fall outside the scope of this document.<\/p>\n
ISO\/TS 19264\u20112<\/span> <\/span> will address transmissive materials.<\/p>\n<\/div>\n Photography. Archiving systems – Best practices for digital image capture of cultural heritage material<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 7<\/td>\n Foreword <\/td>\n<\/tr>\n \n 8<\/td>\n Introduction <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Analysis of image quality
2.1 General
2.2 Image quality characteristics <\/td>\n<\/tr>\n\n 10<\/td>\n 2.3 ISO\u00a019264 Test chart technical features
2.4 Grid and gray\/white features
2.4.1 General <\/td>\n<\/tr>\n\n 11<\/td>\n 2.4.2 Running scale features (cm and inches)
2.4.3 Grayscale and running gray\/white\/black bar features
2.4.4 Colour patch features <\/td>\n<\/tr>\n\n 12<\/td>\n 2.4.5 MTF measurement features
2.4.6 Additional ISO\u00a019264 target features\/reference data
2.5 Additional targets <\/td>\n<\/tr>\n\n 13<\/td>\n 2.6 Linear grayscale
2.6.1 DCSG colour chart
2.6.2 Limitations of Chart Based Imaging System Analysis <\/td>\n<\/tr>\n\n 14<\/td>\n 3 Image quality levels
4 Basic principles of image capture and processing
4.1 Overview <\/td>\n<\/tr>\n\n 15<\/td>\n 4.2 Scene referred and output referred image states
4.3 User controls and readouts
4.3.1 General
4.3.2 Colour Processing Controls <\/td>\n<\/tr>\n\n 16<\/td>\n 4.3.3 Exposure readouts
4.3.4 Raw processor readouts and controls
4.3.5 Other user controls
4.3.6 Unwanted data modification
4.4 Master images and derivatives
4.4.1 General
4.4.2 Raw image files <\/td>\n<\/tr>\n\n 17<\/td>\n 4.4.3 Artwork reproduction cycle <\/td>\n<\/tr>\n \n 18<\/td>\n 5 Imaging system setup and calibration
5.1 General
5.2 Position camera system
5.3 Establish uniformity-even illumination
5.3.1 General
5.3.2 Optional flat-fielding <\/td>\n<\/tr>\n\n 19<\/td>\n 5.4 Establish exposure
5.5 Establish tone reproduction curve (OECF)
5.6 Create an ICC colour profile <\/td>\n<\/tr>\n\n 20<\/td>\n 5.7 Analyse colour and tone
6 Application of image quality analysis
6.1 Selection of imaging systems: preflighting equipment or vendors <\/td>\n<\/tr>\n\n 21<\/td>\n 6.2 Using ISO\u00a019264 target: Initial system configuration
6.3 Using ISO\u00a019264 target: System performance evaluation (benchmarking)
6.4 Using ISO\u00a019264 target: Ongoing performance monitoring <\/td>\n<\/tr>\n\n 22<\/td>\n 7 Technical metadata for image quality analysis <\/td>\n<\/tr>\n \n 23<\/td>\n Annex\u00a0A (informative) Linear Grayscale L* to RGB conversion table <\/td>\n<\/tr>\n \n 24<\/td>\n Annex\u00a0B (informative) Subjective interpretive imaging (aesthetics) <\/td>\n<\/tr>\n \n 27<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2017<\/td>\n 30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":341430,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[40,2641],"product_tag":[],"class_list":{"0":"post-341424","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-01-040-37","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/341424","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/341430"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=341424"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=341424"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=341424"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}