{"id":254822,"date":"2024-10-19T16:50:26","date_gmt":"2024-10-19T16:50:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60269-62011\/"},"modified":"2024-10-25T12:16:26","modified_gmt":"2024-10-25T12:16:26","slug":"bs-en-60269-62011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60269-62011\/","title":{"rendered":"BS EN 60269-6:2011"},"content":{"rendered":"
IEC 60269-6:2010 gives supplementary requirement to those given in IEC 60269-1 for fuse-links for protecting photovoltaic (PV) strings and photovoltaic (PV) arrays in equipment for circuits of nominal voltages up to 1 500 V d.c. This publication is to be read in conjunction with \/2.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 General 1.1 Scope and object 1.2 Normative references <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 2 Terms and definitions 2.2 General terms <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3 Conditions for operation in service 3.4 Voltage 3.5 Current 3.6 Frequency, power factor and time constant <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3.10 Temperature inside an enclosure 4 Classification 5 Characteristics of fuses 5.1 Summary of characteristics 5.2 Rated voltage 5.5 Rated power dissipation of the fuse-link 5.6 Limits of time-current characteristics <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.7 Breaking range and breaking capacity 6 Markings 6.2 Markings on fuse-links 7 Standard conditions for construction 7.5 Breaking capacity Tables Table 101 \u2013 Conventional times and currents for “gPV\u201d fuse-links <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 8 Tests 8.1 General Table 102 \u2013 Survey of complete tests on fuse-links and number of fuse-links to be tested <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 8.3 Verification of temperature rise limits and power dissipation Table 103 \u2013 Survey of tests on fuse-links of the smallest rated current of a homogeneous series and number of fuse-links to be tested <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 8.4 Verification of operation 8.5 Verification of the breaking capacity <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 8.11 Mechanical and miscellaneous tests Table 104 \u2013 Values for breaking-capacity tests on \u201cgPV\u201d fuse-links <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figures Figure 101 \u2013 Current of test cycling <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex AA (normative) Examples of standardized fuse-links for the protection of solar photovoltaic energy systems <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure AA.1 \u2013 Fuse-links with cylindrical contact caps, type A <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Figure AA.2 \u2013 Fuse-links with cylindrical contact caps type A with striker \u2013 Additional dimensions for sizes 14 x 51, 20 x 127 and 22 x 127 only <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure AA.3 \u2013 North American cylindrical fuse-links with blade contacts \u2013 Sizes 61- 600 A <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure AA.4 \u2013 Fuse-links with blade contacts, type C, C referring IEC\u00a060269-2 \u201cFuse system A (NH fuse system)\u201d <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure AA.5 \u2013 Fuse-links with long blade contacts, type D <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex BB (informative) Guidance for the protection of photovoltaic strings and arrays with fuse-links designed for PV applications <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Low-voltage fuses – Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems<\/b><\/p>\n |