{"id":242753,"date":"2024-10-19T15:55:07","date_gmt":"2024-10-19T15:55:07","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-631032020\/"},"modified":"2024-10-25T10:49:01","modified_gmt":"2024-10-25T10:49:01","slug":"bs-en-iec-631032020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-631032020\/","title":{"rendered":"BS EN IEC 63103:2020"},"content":{"rendered":"

IEC 63103:2020(E) specifies methods of measurement of electrical power consumption in non-active mode(s), as applicable for electrical lighting equipment. This includes electrical lighting equipment incorporating non-illumination components. This document specifies neither performance requirements nor limits on power consumption. This document applies to lighting equipment connected to a supply voltage up to 1 500 V DC or up to 1 000 V AC. This document is intended to be referenced by lighting equipment product standards for the measurement of non-active mode power consumption. Details for the non-active mode power consumption measurement and data presentation are specified in the product standards.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
7<\/td>\nCONTENTS <\/td>\n<\/tr>\n
9<\/td>\nFOREWORD <\/td>\n<\/tr>\n
11<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
13<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
16<\/td>\n4 General test conditions
4.1 General
4.2 Laboratory and environmental conditions
4.3 Supply voltage
4.3.1 Supply voltage and frequency
4.3.2 Supply voltage waveform
4.4 Power measurement accuracy and uncertainty <\/td>\n<\/tr>\n
17<\/td>\n4.5 Network aspects
4.5.1 General
4.5.2 Wired networks
4.5.3 Wireless networks: conducted connection for testing <\/td>\n<\/tr>\n
18<\/td>\n4.5.4 Wireless networks: radiated connection for testing
Figures
Figure 1 \u2013 Test setup for non-active mode power consumption measurementof conducted connected EUT <\/td>\n<\/tr>\n
19<\/td>\nFigure 2 \u2013 Test setup for non-active mode power consumption measurementof connected EUT with integral antennas (RF path symbolically shown)
Figure 3 \u2013 Calibration setup for non-active mode power measurementof connected EUT with integral antennas <\/td>\n<\/tr>\n
20<\/td>\n5 Measurements
5.1 General
5.2 Equipment under test (EUT)
5.2.1 General
5.2.2 Illumination-only lighting equipment
Figure 4 \u2013 Components present within illumination-only EUT <\/td>\n<\/tr>\n
22<\/td>\nTables
Table 1 \u2013 Configurations and examples of illumination-only equipmentand reference to the measurement setup <\/td>\n<\/tr>\n
23<\/td>\nTable 2 \u2013 Template for reporting non-active mode power
Table 3 \u2013 Example of using the template of Table 2for reporting measured standby power for an illumination-only luminairewith integrated presence sensor <\/td>\n<\/tr>\n
24<\/td>\n5.2.3 Multi-function lighting equipment
Figure 5 \u2013 Component representing an additional function (AF) of multi-function EUT
Figure 6 \u2013 Configuration of multi-function lighting equipment:example including one additional function <\/td>\n<\/tr>\n
25<\/td>\n5.3 Preparation of EUT
5.3.1 General
5.3.2 Measurement of input power
Table 4 \u2013 Example of using the template of Table 2for reporting measured standby power for a (multi-function) luminairewith an integrated presence sensor and an integrated camera <\/td>\n<\/tr>\n
27<\/td>\n5.3.3 EUT with no network provision
5.3.4 EUT with network provision (wired or wireless)
5.4 Measuring procedure
5.4.1 General <\/td>\n<\/tr>\n
28<\/td>\n5.4.2 Direct meter reading method
5.4.3 Average reading method <\/td>\n<\/tr>\n
29<\/td>\n5.4.4 Sampling method <\/td>\n<\/tr>\n
31<\/td>\nAnnex A (informative)Guidance for product standards <\/td>\n<\/tr>\n
32<\/td>\nAnnex B (normative)Measurement setup schemesfor illumination-only lighting equipment
Figure B.1 \u2013 Key to symbols used in figures of Annex B
Figure B.2 \u2013 Measurement setup for determining the input powersupplied to the power supply <\/td>\n<\/tr>\n
33<\/td>\nFigure B.3 \u2013 Measurement setup (with optional network provision)for determining the input power supplied to the control unit
Figure B.4 \u2013 Measurement setup (with optional network provision) for determining the input power supplied to the combined power supply and control unit
Figure B.5 \u2013 Measurement setup for determining the input power suppliedto the combined light source and power supply
Figure B.6 \u2013 Measurement setup (with optional network provision) for determining the input power supplied to the combined light source and control unit <\/td>\n<\/tr>\n
34<\/td>\nFigure B.7 \u2013 Measurement setup (with optional network provision) for determiningthe input power supplied to illumination-only lighting equipment <\/td>\n<\/tr>\n
35<\/td>\nAnnex C (normative)Measurement setup schemes for multi-function lighting equipment
Figure C.1 \u2013 Key to symbols used in figures of Annex C
Figure C.2 \u2013 Measurement setup (with optional network provision) for determining the input power to multi-function lighting equipment <\/td>\n<\/tr>\n
36<\/td>\nAnnex D (informative)Application examples
Figure D.1 \u2013 General measurement setup scheme for controlgear examples <\/td>\n<\/tr>\n
37<\/td>\nFigure D.2 \u2013 Networked standby mode measurement setup for the “basic” controlgear
Figure D.3 \u2013 Networked standby mode measurement setup for controlgearwith an integrated auxiliary\/bus power supply function <\/td>\n<\/tr>\n
38<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Lighting equipment. Non-active mode power measurement<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":242758,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[526,2641],"product_tag":[],"class_list":{"0":"post-242753","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-140-99","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/242753","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/242758"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=242753"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=242753"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=242753"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}