Shopping Cart

No products in the cart.

BS EN 60728-7-3:2009 2010

$167.15

Cable networks for television signals, sound signals and interactive services – Hybrid fibre coax outside plant status monitoring. Power supply to transponder interface bus (PSTIB)

Published By Publication Date Number of Pages
BSI 2010 42
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60728-7-3:2009(E) specifies requirements for the Hybrid Fibre Coax (HFC) Outside Plant (OSP) Power Supplies (PS). This standard is part of a series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The purpose of the standards is to support the design and implementation of interoperable management systems for evolving HFC cable networks. The Power Supply to Transponder Interface Bus (PSTIB) specification describes the physical (PHY) interface and related messaging and protocols implemented at the Data Link Layer (DLL), layers 1 and 2 respectively in the 7-layer ISO-OSI reference model, that support communications between compliant transponders and the managed OSP power supplies and other related power equipment to which they interface. It constitutes a technical revision and includes the following significant technical changes with respect to the previous edition: All changes from standard ANSI/SCTE 25-3 v1.0 to standard ANSI/SCTE 25-3 v1.1 (2005) have been taken into account in this second edition. Clause 7 is based on standard ANSI/SCTE 110 (2005). Addition of informative Annex A concerning hybrid management sub-layer.

PDF Catalog

PDF Pages PDF Title
6 CONTENTS
9 INTRODUCTION
10 1 Scope
Tables
Table 1 – Transponder type classifications
11 2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
12 3.2 Abbreviations
4 Reference architecture forward and return channel specifications
13 5 Power supply to transponder interface bus specification overview
5.1 General
5.2 Interface compliance
5.3 Implementation compliance
Figures
Figure 1 – Reference architecture diagram
14 5.4 Revision control
6 Power supply to transponder interface bus – Physical layer specification
6.1 Interface requirements
Table 2 – RJ-45 Connector pin assignment
16 6.2 Interface diagram
Figure 2 – Sample PSTIB RS-485 interface
Table 3 – Sample PSTIB RS-485 interface – Reference signals
17 7 Alternative power supply to transponder interface bus – Physical layer specification
7.1 Introduction to alternative
7.2 Interface requirements
Table 4 – RJ-45 Connector pin assignment
19 7.3 Interface diagram
Figure 3 – Sample PSTIB RS-485 interface
Table 5 – Sample PSTIB RS-485 interface – Reference signals
20 8 Power supply to transponder interface bus – Data link layer specification
8.1 DLL packet structure
Figure 4 – DLL packet structure
Table 6 – Generic DLL packet structure
21 8.2 DLE sequence
Table 7 – Reserved destination address ranges
22 8.3 Interface timing
23 Figure 5 – PSTIB data and timing diagram
Table 8 – PSTIB timing specifications
24 8.4 DLL datagrams
Figure 6 – DLL datagram structure
Table 9 – Generic DLL datagram structure
26 Table 10 – DLL datagrams
Table 11 – Command: Get_Configuration datagram
27 Table 12 – Response: Get_Configuration datagram
Table 13 – Response: Get_Configuration datagram a variable binding (general)
28 Table 14 – Response: Get_Configuration datagram a, b variable binding (power supply)
31 Table 15 – Response: Get_Configuration datagram a variable binding (generator)
32 Table 16 – Command: Get_Power_Supply_Data datagram
Table 17 – Response: Get_Power_Supply_Data datagram
Table 18 – Response: Get_Power_Supply_Data datagram variable binding
35 Figure 7 – Battery string naming conventions
Table 19 – Command: Power_Supply_Control datagram
Table 20 – Command: Get_Generator_Data datagram
36 Table 21 – Response: Get_Generator_Data datagram
Table 22 – Response: Get_Generator_Data Datagram variable binding
37 Table 23 – Command: Generator_Control datagram
Table 24 – Response: Invalid_Request datagram
38 Table 25 – Response: Request_Processed datagram
39 Annex A (informative) HMS specification documents
Table A.1 – HMS document family
40 Bibliography
BS EN 60728-7-3:2009 2010