BS 8499:2017
$198.66
Specification for domestic gas meter boxes and meter bracket
Published By | Publication Date | Number of Pages |
BSI | 2017 | 60 |
This British Standard specifies requirements for gas meter boxes for use with single gas meter installations conforming to BS 6400, which:
-
are supplied with gases of the 2nd and 3rd family, with a maximum capacity of 6 m3/h and a maximum operating pressure not exceeding 2 bar; and
-
incorporate any of the following meters: diaphragm, ultrasonic, credit or prepayment.
It does not apply to multiple meter installations which are installed in the same housing.
NOTE 1 The composition of fuel gases of the 2nd and 3rd family is specified in BS EN 437.
NOTE 2 All pressures quoted in this standard are gauge pressures.
It covers the following designs of meter box, including any associated box extensions:
-
built-in;
-
surface mounted;
-
semi-concealed;
-
universal.
It does not cover security shrouds intended to provide additional protection to meter installations.
This British Standard also specifies requirements for the design of the standard meter bracket.
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | Foreword |
7 | Introduction 1 Scope 2 Normative references |
9 | 3 Terms and definitions |
11 | 4 Dimensions and features |
13 | Figure 1 — Typical meter box adaptor with ECV and cap |
14 | Figure 2 — Built-in box dimensions and features |
16 | Figure 3 — Surface mounted box dimensions and features |
18 | Figure 4 — Recommended dimensions and features for new semi-concealed box designs |
20 | Figure 5 — Universal box dimensions and features |
21 | 5 Meter bracket (supplied separately) 6 Spigot Figure 6 — Spigot dimensions 7 Materials |
22 | 8 Finish 9 Marking |
23 | 10 Notices and labels |
24 | Figure 7 — Typical emergency notice |
25 | Figure 8 — Typical combined emergency notice Figure 9 — Spigot knockout warning label (built-in boxes) |
26 | Figure 10 — Medium pressure service warning label |
27 | Figure 11 — Typical manufacturer’s label |
28 | 11 Type testing and performance requirements Table 1 — Flexural properties of box samples Table 2 — Charpy impact strength of box samples Table 3 — Hinge strength |
30 | Annex A (normative) Meter box key Figure A.1 — Meter box key |
31 | Annex B (normative) Meter bracket |
33 | Figure B.1 — Meter bracket dimensions |
35 | Figure B.2 — Meter bracket shear bolt dimensions |
36 | Figure B.3 — Meter bracket security washer dimensions |
37 | Figure B.4 — Location points for measurement of thickness of zinc coatings on meter brackets |
38 | Annex C (normative) Polyester moulding compound production testing Table C.1 — Flexural properties of test plaques |
39 | Table C.2 — Charpy impact strength of test plaques Annex D (normative) Selection of meter box samples and test plaques for testing |
40 | Figure D.1 — Basic cutting plan |
41 | Annex E (informative) General instructions labels |
42 | Figure E.1 — Built-in box general instructions (typical) |
43 | Figure E.2 — Surface mounted box general instructions (typical) |
44 | Figure E.3 — Semi-concealed box general instructions (typical) |
45 | Figure E.4 — Universal box general instructions (typical) |
46 | Annex F (normative) Methods of test for hinge strength Figure F.1 — Built-in and surface mounted hinge strength test |
47 | Figure F.2 — Typical apparatus for semi-concealed and universal box hinge strength test |
48 | Annex G (normative) Method of test for door flatness (built-in and surface mounted boxes) Annex H (normative) Cutting plans for meter box test samples |
49 | Figure H.1 — Locations of built-in box body cutting plan |
52 | Figure H.2 — Location of built-in box door cutting plan |
53 | Figure H.3 — Location of surface mounted box cover cutting plan |
54 | Figure H.4 — Location of surface mounted box back panel cutting plan |
55 | Figure H.5 — Location of surface mounted box door cutting plan |
56 | Figure H.6 — Location of semi-concealed box body cutting plan |
57 | Figure H.7 — Location of semi-concealed box lid cutting plan |
58 | Figure H.8 — Location of semi-concealed box extension cutting plan |
59 | Bibliography |