ASTM-E1606:2009 Edition
$35.75
E1606-09 Standard Practice for Electromagnetic (Eddy-Current) Examination of Copper Redraw Rod for Electrical Purposes
Published By | Publication Date | Number of Pages |
ASTM | 2009 | 4 |
ASTM E1606-09
Historical Standard: Standard Practice for Electromagnetic (Eddy-Current) Examination of Copper Redraw Rod for Electrical Purposes
ASTM E1606
Scope
1.1 This practice covers the procedures that shall be followed in electromagnetic (eddy-current) examination of copper redraw rods for detecting discontinuities or imperfections of a severity likely to cause failure or markedly impair surface quality of the rod. These procedures are applicable for continuous lengths of redraw rod in diameters from ¼ to 13/8 in. (6.4 to 35 mm) suitable for further fabrication into electrical conductors.
1.2 This practice covers redraw rod made from tough-pitch or oxygen-free coppers.
1.3 The procedures described in this practice are based on methods for making use of stationary encircling annular test coil systems.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
copper redraw rod; eddy-current examination; eddy-current testing; electromagnetic examination; electromagnetic testing ; standards; Calibration–nondestructive analysis instrumentation; Copper (electromagnetic testing); Copper redraw rod; Eddy current examination; Electromagnetic (eddy current) testing; Redraw rod
ICS Code
ICS Number Code 29.050 (Superconductivity and conducting materials)
DOI: 10.1520/E1606-09
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Practice Significance and Use |
2 | Basis of Application Apparatus Standards FIG. 1 |
3 | Adjustment and Standardization of Apparatus Sensitivity Procedure Keywords |
4 | X1. SUGGESTED EQUIPMENT TO PASS STANDARDS THROUGH A TEST COIL X1.1 FIG. X1.1 |