{"id":60826,"date":"2024-10-17T11:30:27","date_gmt":"2024-10-17T11:30:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d3686-2001\/"},"modified":"2024-10-24T17:50:43","modified_gmt":"2024-10-24T17:50:43","slug":"astm-d3686-2001","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d3686-2001\/","title":{"rendered":"ASTM-D3686 2001"},"content":{"rendered":"<\/p>\n

1.1 This practice covers a method for the sampling of atmospheres for determining the presence of certain organic vapors by means of adsorption on activated charcoal using a charcoal tube and a small portable sampling pump worn by a worker. A list of some of the organic chemical vapors that can be sampled by this practice is provided in Annex 1. This list is presented as a guide and should not be considered as absolute or complete.<\/p>\n

1.2 This practice does not cover any method of sampling that requires special impregnation of activated charcoal or other adsorption media.<\/p>\n

1.3 The values stated in SI units are to be regarded as the standard.<\/p>\n

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i> A specific safety precaution is given in .<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Summary of Practice
Significance and Use <\/td>\n<\/tr>\n
2<\/td>\nInterferences
Apparatus
FIG. 1 <\/td>\n<\/tr>\n
3<\/td>\nReagents
Sampling with Activated Charcoal Samplers <\/td>\n<\/tr>\n
4<\/td>\nHandling and Shipping of Samples Collected on Charcoal Sampling Tubes
Keywords
A1. INFORMATION OF SOME ORGANIC COMPOUND VAPORS THAT CAN BE COLLECTED ON COCONUT-SHELL CHARCOAL (100\/50 mg tubes) <\/p>\n

TABLE A1.1 <\/td>\n<\/tr>\n

7<\/td>\nA2. METHOD FOR CALIBRATION OF SMALL VOLUME AIR PUMPS
A2.1
A2.2
A2.3
A2.4
A2.5 <\/td>\n<\/tr>\n
8<\/td>\nREFERENCES
FIG. A2.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D3686-95(2001)e1 Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2001<\/td>\n8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":60827,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[203,2637],"product_tag":[],"class_list":{"0":"post-60826","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-040-20","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/60826","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/60827"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=60826"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=60826"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=60826"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}