{"id":495509,"date":"2024-11-05T12:54:03","date_gmt":"2024-11-05T12:54:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/as-4072-11992\/"},"modified":"2024-11-05T12:54:03","modified_gmt":"2024-11-05T12:54:03","slug":"as-4072-11992","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/as\/as-4072-11992\/","title":{"rendered":"AS 4072.1:1992"},"content":{"rendered":"

Specifies requirements for the testing, interpretation of test results, installation and certification of penetration sealing systems and control joints sealing systems in fire-separating elements of construction. The Standard is based on the testing of standard configurations and provides minimum requirements for these fire-stopping systems. It is intended to complement the fire-protection requirements of the Building Code of Australia and is to be read in conjunction with AS 1530.4. Methods for fire tests on building materials, components and structures – Part 4: Fire-resistance tests of elements of building construction. Specific sections cover basic design requirements, the determination of fire-resistance, the permissible variations from the tested prototype and the appraisal of the test results. A commentary which explains the concepts of the testing regime is included together with a suggested test method for evaluating the movement capability of fire-stopping control joint seals. <\/p>\n

Scope<\/b><\/p>\n

This Standard sets out requirements for the testing, interpretation of test results, installation and certification of sealing systems-
(a) around penetrations through separating building elements which are required to have a fire-resistance level or, if applicable, a resistance to the incipient spread of fire; and
(b) at control joints between building elements which are required to have a fire-resistance level. <\/p>\n

NOTE: Explanatory notes and comment on the testing regime are included in Appendix A.<\/p>\n","protected":false},"excerpt":{"rendered":"

Components for the protection of openings in fire-resistant separating elements – Service penetrations and control joints<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
AS<\/b><\/a><\/td>\n1992-12-21<\/td>\n32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":495522,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,2633],"product_tag":[],"class_list":{"0":"post-495509","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-as","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/495509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/495522"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=495509"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=495509"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=495509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}