{"id":453555,"date":"2024-10-20T09:30:54","date_gmt":"2024-10-20T09:30:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-24-30427715-dc\/"},"modified":"2024-10-26T17:38:53","modified_gmt":"2024-10-26T17:38:53","slug":"bsi-24-30427715-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-24-30427715-dc\/","title":{"rendered":"BSI 24\/30427715 DC"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n30427715.PDF <\/td>\n<\/tr>\n
3<\/td>\n9_3049e_CDV.pdf <\/td>\n<\/tr>\n
8<\/td>\nFOREWORD <\/td>\n<\/tr>\n
10<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
12<\/td>\n1 Scope <\/td>\n<\/tr>\n
13<\/td>\n2 Normative references <\/td>\n<\/tr>\n
15<\/td>\n3 Terms, definitions and abbreviated terms
3.1 Defintions <\/td>\n<\/tr>\n
25<\/td>\n3.2 Abbreviated terms <\/td>\n<\/tr>\n
26<\/td>\n4 Configuration of the fuel cell power system
4.1 Fuel cell power system definition <\/td>\n<\/tr>\n
27<\/td>\n4.2 Subsystems of the fuel cell power system
4.3 PEM Fuel Cell <\/td>\n<\/tr>\n
28<\/td>\n5 Environmental requirements
5.1 General <\/td>\n<\/tr>\n
29<\/td>\n5.2 Specific use case
5.2.1 Rooftop installation
5.2.2 Tunnel
5.2.3 Performance limitation at low and high ambient temperature
5.2.4 Performance limitation at high altitude <\/td>\n<\/tr>\n
31<\/td>\n6 Interface requirements
6.1 General
6.2 Fluidic Interfaces
6.2.1 Fuel supply
6.2.2 Oxidant Supply <\/td>\n<\/tr>\n
32<\/td>\n6.2.3 Coolant
6.2.4 Air inlets
6.2.5 Exhaust <\/td>\n<\/tr>\n
33<\/td>\n6.3 Electrical interfaces
6.3.1 General
6.3.2 Main Power interface <\/td>\n<\/tr>\n
34<\/td>\n6.3.3 Auxiliary supply and communication interfaces <\/td>\n<\/tr>\n
35<\/td>\n7 Performance requirements
7.1 General
7.2 Fuel cell power system sizing
7.3 Load Profile <\/td>\n<\/tr>\n
36<\/td>\n7.4 Operational requirements
7.4.1 Normal mode requirements
7.4.2 Degraded mode requirements
7.5 Electric efficiency and hydrogen consumption calculations
7.6 Lifetime requirements <\/td>\n<\/tr>\n
37<\/td>\n7.7 End of life performance
7.8 Voltage stability <\/td>\n<\/tr>\n
38<\/td>\n8 Design Requirements
8.1 General
8.2 FMS Requirements
8.2.1 Design requirement
8.2.1.1 Piping
8.2.1.2 Hydrogen compatibility
8.2.1.3 Leak tightness
8.2.1.4 Ultimate strength pressure <\/td>\n<\/tr>\n
39<\/td>\n8.2.1.5 Hydrogen quality
8.2.1.6 Filtering device
8.2.2 Functional requirement
8.2.2.1 First start-up
8.2.2.2 Maintenance operation <\/td>\n<\/tr>\n
40<\/td>\n8.3 OMS requirements
8.3.1 Design requirement
8.3.1.1 General
8.3.1.2 Non-metallic piping
8.3.1.3 Over pressure
8.3.1.4 Oxidant quality \/ Filtering device
8.4 TMS Requirements
8.4.1 Design requirements
8.4.1.1 General <\/td>\n<\/tr>\n
41<\/td>\n8.4.1.2 Sizing
8.4.1.3 Material selection
8.4.1.4 Filtering device
8.4.1.5 Coolant selection
8.4.1.6 Coolant conductivity <\/td>\n<\/tr>\n
42<\/td>\n8.4.1.7 Over pressure \/ Ultimate strength
8.4.1.8 Surge tank
8.4.1.9 Heat exchanger
8.4.2 Functional requirements
8.4.2.1 Operating mode
8.4.2.2 Warm-up phase
8.5 ExMS requirements
8.5.1 Hydrogen release
8.5.2 Waste Water <\/td>\n<\/tr>\n
43<\/td>\n8.6 EPMS requirements
8.6.1 General
8.6.2 Cabling
8.6.3 Ripple current
8.6.4 Electric power input
8.6.5 Auxiliary motors <\/td>\n<\/tr>\n
44<\/td>\n8.6.6 Light maintenance operation
8.7 MCS requirements
8.7.1 Hardware
8.7.2 Software
8.8 Mechanical requirements
8.8.1 Mechanical integration <\/td>\n<\/tr>\n
45<\/td>\n8.8.2 Mechanical design
8.8.3 Bolted assemblies
8.8.4 Degree of protection
8.8.5 Shock & vibration <\/td>\n<\/tr>\n
46<\/td>\n8.9 Recyclability requirements
8.10 Documentation <\/td>\n<\/tr>\n
47<\/td>\n8.11 Other
8.11.1 Noise Emission requirements
8.11.2 EMC requirements <\/td>\n<\/tr>\n
49<\/td>\n9 Safety, reliability and protection requirements
9.1 Reliability
9.2 Safety
9.2.1 Safety analysis <\/td>\n<\/tr>\n
50<\/td>\n9.2.2 Hazard Identification
9.2.3 Prevention for maintenance operation and storage <\/td>\n<\/tr>\n
51<\/td>\n9.2.4 Hydrogen risk management
9.2.4.1 Grade of release of Hydrogen
9.2.4.2 Requirements related to the grade of release of hydrogen \u2013 type A
9.2.4.3 Requirements related to the grade of release of hydrogen \u2013 type B <\/td>\n<\/tr>\n
52<\/td>\n9.2.4.4 Requirements related to the grade of release of hydrogen \u2013 type C
9.2.4.5 Explosive atmosphere analysis
9.2.4.6 Leak Detection
9.2.4.7 Hydrogen accumulation risk <\/td>\n<\/tr>\n
53<\/td>\n9.2.5 Fire, smoke, flammability
9.2.6 Electrical shock
9.2.7 Software <\/td>\n<\/tr>\n
54<\/td>\n10 Marking and labelling
10.1 Safety signs
10.1.1 FCPS enclosure
10.1.2 Other places inside the FCPS enclosure
10.2 Nameplate
10.2.1 FCPS enclosure
10.2.2 Nameplates on sub-assemblies inside the box <\/td>\n<\/tr>\n
56<\/td>\n11 Installation and Maintenance
11.1 General
11.2 Installation
11.3 Maintenance
11.3.1 General
11.3.2 Maintenance accessibility
11.3.3 Technical documentation <\/td>\n<\/tr>\n
58<\/td>\n12 FCPS storage and transportation conditions
12.1 General
12.2 Transportation
12.3 Storage <\/td>\n<\/tr>\n
59<\/td>\n13 Testing
13.1 General
13.2 Parameter measurements
13.3 Parameter measurement tolerances
13.4 Reference test conditions
13.4.1 Laboratory conditions <\/td>\n<\/tr>\n
60<\/td>\n13.4.2 Installation and operating conditions of the system
13.4.3 Quality of hydrogen
13.4.4 Quality of power input
13.5 Type test
13.5.1 General
13.5.2 Tests on sub-assemblies
13.5.2.1 FCPM level test
13.5.2.1.1 Differential pressure test
13.5.2.2 Optional type tests at component level
13.5.3 Visual checks <\/td>\n<\/tr>\n
61<\/td>\n13.5.4 Weight
13.5.5 Communication network test
13.5.6 Dielectric voltage strength test
13.5.7 Insulation impedance (optional)
13.5.8 Sub-equipment functional tests (optional)
13.5.9 Operating test for stabilized operations <\/td>\n<\/tr>\n
62<\/td>\n13.5.10 Operating test for dynamic operations
13.5.11 Polarization curve Test
13.5.12 Output power characteristics test
13.5.13 Load Profile Test
13.5.14 Hydrogen leakage test
13.5.15 Ultimate Strength Pressure test
13.5.15.1 Hydrogen
13.5.15.2 Coolant <\/td>\n<\/tr>\n
63<\/td>\n13.5.16 Flammable concentration test
13.5.17 Thermal rising test
13.5.18 Endurance test (optional)
13.5.19 Safety Test in abnormal conditions
13.5.20 Hydrogen Emissions
13.5.21 Environmental tests
13.5.21.1 Shock and vibration test <\/td>\n<\/tr>\n
64<\/td>\n13.5.21.2 Power Generation Test at low and high temperature
13.5.21.3 Power Generation Test under low and high humidity conditions
13.5.21.4 Ultra Violet \/ Solar radiation test
13.5.21.5 Ingress of protection against water (IP test)
13.5.21.6 Altitude test
13.5.21.7 Thermal cycling (optional) <\/td>\n<\/tr>\n
65<\/td>\n13.5.21.8 Salt mist test (optional)
13.5.22 Acoustic noise emissions
13.5.23 EMC test
13.6 Routine test
13.6.1 Visual checks
13.6.2 Communication network test
13.6.3 Dielectric test
13.6.4 Insulation impedance test (optional)
13.6.5 normal operation test <\/td>\n<\/tr>\n
66<\/td>\n13.6.6 Hydrogen leakage test
13.6.7 Overpressure test <\/td>\n<\/tr>\n
67<\/td>\nAnnex A (informative): Datasheet Template Proposal <\/td>\n<\/tr>\n
70<\/td>\nAnnex B (Informative): Informative Bibliography
1 IEC optional standard list: <\/td>\n<\/tr>\n
71<\/td>\n2 Local laws, regulations and standards applicable
2.1 Europe
2.2 Japan <\/td>\n<\/tr>\n
72<\/td>\n2.3 China <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

BS EN IEC 63341-1 Railway applications \u2013 Rolling stock \u2013 Fuel cell systems for propulsion – Part 1: Fuel Cell System<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2024<\/td>\n72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":453565,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-453555","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/453555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/453565"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=453555"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=453555"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=453555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}