{"id":440802,"date":"2024-10-20T08:17:34","date_gmt":"2024-10-20T08:17:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-19642-22023-tc\/"},"modified":"2024-10-26T15:29:08","modified_gmt":"2024-10-26T15:29:08","slug":"bs-iso-19642-22023-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-19642-22023-tc\/","title":{"rendered":"BS ISO 19642-2:2023 – TC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
116<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | 3 Terms and definitions 4 Specifications 4.1 General test conditions 4.1.1 General information on dimensional tests <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | 4.2 Safety concerns 4.3 Ovens 5 Test methods for single core cables 5.1 General 5.2 Dimensional tests 5.2.1 Cable outside diameter <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | 5.2.2 Insulation thickness 5.2.3 Conductor diameter 5.2.4 Cross-sectional area (CSA) <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | 5.2.5 In-process cable outside diameter <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | 5.3 Electrical tests 5.3.1 Conductor resistance <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | 5.3.2 Determination of temperature coefficients <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | 5.3.3 Withstand voltage <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | 5.3.4 Withstand voltage after environmental testing 5.3.5 Insulation faults <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | 5.3.6 Insulation volume resistivity 5.4 Mechanical tests 5.4.1 Strip force <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | 5.4.2 Abrasion <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | 5.4.3 Breaking force of the finished cable <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | 5.4.4 Cyclic bending <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | 5.4.5 Flexibility <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | 5.5 Environmental tests 5.5.1 Test specimen preparation and winding tests <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | 5.5.2 Long term heat ageing, 3 000 h at temperature class rating 5.5.3 Short term heat ageing, 240 h at temperature class rating +25 \u00b0C <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | 5.5.4 Thermal overload, 6 h at temperature class rating +50 \u00b0C 5.5.5 Pressure test at high temperature <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | 5.5.6 Shrinkage by heat 5.5.7 Low temperature winding 5.5.8 Cold impact <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | 5.5.9 Temperature and humidity cycling <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | 5.5.10 Resistance to hot water <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | 5.5.11 Resistance to liquid chemicals <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | 5.5.12 Durability of cable marking 5.5.13 Stress cracking resistance <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | 5.5.14 Resistance to ozone <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | 5.5.15 Resistance to flame propagation <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | 6 Test methods for sheathed and\/or multi-conductor cables 6.1 General <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | 6.2 Dimensional tests 6.2.1 Cable outside diameter 6.2.2 Ovality of sheath 6.2.3 Thickness of sheath 6.2.4 In-process cable outside diameter <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | 6.2.5 Lay length <\/td>\n<\/tr>\n | ||||||
160<\/td>\n | 6.3 Electrical tests 6.3.1 Electrical continuity 6.3.2 Withstand voltage at final inspection 6.3.3 Screening effectiveness <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | 6.3.4 Sheath fault on screened cables <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | 6.3.5 General information on electrical test setups of unscreened balanced cables <\/td>\n<\/tr>\n | ||||||
168<\/td>\n | 6.3.6 General information on low frequency electrical tests 6.3.7 Resistance unbalance <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | 6.3.8 Capacitance <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | 6.3.9 Inductance 6.3.10 General information on high radio frequency (RF) electrical tests <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | 6.3.11 Velocity of propagation <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | 6.3.12 Characteristic impedance in frequency domain (CIF) <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | 6.3.13 Characteristic impedance in time domain (CIT) <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | 6.3.14 Insertion loss, (IL) 6.3.15 Return loss, (RL) 6.3.16 Unbalance attenuations <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | 6.3.17 Near-end crosstalk, NEXT 6.3.18 Far-end crosstalk, FEXT 6.3.19 PS alien near-end crosstalk, PS-ANEXT \u2013 exogenous crosstalk 6.3.20 PS attenuation to alien far-end crosstalk ratio, PS-AACR-F – exogenous crosstalk <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | 6.4 Mechanical tests 6.4.1 Strip force of sheath 6.4.2 Cyclic bending 6.4.3 Flexibility <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | 6.4.4 Cyclic bending test for RF cables <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | 6.4.5 Dynamic bending tests for RF cables <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | 6.4.6 Test for assessment of minimum bending radius <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | 6.4.7 Strip force of screen <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | 6.4.8 Abrasion test of sheath 6.5 Environmental tests 6.5.1 Test specimen preparation and winding tests <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | 6.5.2 Long-term heat ageing, 3 000 h at temperature class rating <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | 6.5.3 Short term heat ageing, 240 h at temperature class rating +25 \u00b0C 6.5.4 Thermal overload, 6 h at temperature class rating +50 \u00b0C 6.5.5 Pressure test at high temperature 6.5.6 Shrinkage by heat of sheath <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | 6.5.7 Low temperature winding 6.5.8 Cold impact 6.5.9 Temperature and humidity cycling <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | 6.5.10 Resistance to liquid chemicals 6.5.11 Durability of sheath marking <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | 6.5.12 Resistance to ozone 6.5.13 Artificial weathering 6.5.14 Resistance to flame propagation <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | Annex A (informative) Examples of materials and sources suppliers <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | Annex B (informative) Flexibility test apparatus <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | Annex C (normative) Flame test apparatus <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | Annex D (informative) Concentricity, A-Factor, Fx,A <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Road vehicles. Automotive cables – Test methods<\/b><\/p>\n |