{"id":255825,"date":"2024-10-19T16:54:47","date_gmt":"2024-10-19T16:54:47","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-6469-32018a12020\/"},"modified":"2024-10-25T12:23:06","modified_gmt":"2024-10-25T12:23:06","slug":"bs-iso-6469-32018a12020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-6469-32018a12020\/","title":{"rendered":"BS ISO 6469-3:2018+A1:2020"},"content":{"rendered":"
This document specifies electrical safety requirements for voltage class B electric circuits of electric propulsion systems and conductively connected auxiliary electric systems of electrically propelled road vehicles.<\/p>\n
It specifies electrical safety requirements for protection of persons against electric shock and thermal incidents.<\/p>\n
It does not provide comprehensive safety information for manufacturing, maintenance and repair personnel.<\/p>\n
\nNOTE 1 Electrical safety requirements for post-crash are described in ISO 6469\u20114.<\/p>\n<\/blockquote>\n
\nNOTE 2 Electrical safety requirements for conductive connections of electrically propelled road vehicles to an external electric power supply are described in ISO 17409.<\/p>\n<\/blockquote>\n
\nNOTE 3 Specific electrical safety requirements for magnetic field wireless power transfer between an external electric power supply and an electrically propelled vehicle are described in ISO PAS 19363.<\/p>\n<\/blockquote>\n
\nNOTE 4 Electrical safety requirements for motorcycles and mopeds are described in ISO 13063.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n National foreword <\/td>\n<\/tr>\n \n 7<\/td>\n Foreword <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n\n 14<\/td>\n 4 Voltage classes
5 General requirements
5.1 Environmental and operational requirements
5.2 Marking
5.2.1 Marking of voltage class B electric components <\/td>\n<\/tr>\n\n 15<\/td>\n 5.2.2 Marking of voltage class B wiring
6 Requirements for protection of persons against electric shock
6.1 General requirements
6.1.1 General requirements for connected sections of a circuit
6.1.2 General requirements for voltage class B1 <\/td>\n<\/tr>\n\n 16<\/td>\n 6.1.3 General requirements for voltage class B2
6.2 Basic protection
6.3 Fault protection and additional measures
6.3.1 Equipotential bonding
6.3.2 Isolation resistance <\/td>\n<\/tr>\n\n 18<\/td>\n 6.3.3 Provisions for capacitive coupling and capacitive discharge
6.3.4 De-energization
6.3.5 Alternative protection measures <\/td>\n<\/tr>\n\n 19<\/td>\n 6.4 General requirements for protective provisions
6.4.1 General
6.4.2 Requirements for insulation
6.4.3 Requirements for protective barriers and protective enclosures <\/td>\n<\/tr>\n\n 20<\/td>\n 6.4.4 Requirements for connectors
6.4.5 Insulation Coordination
6.5 Alternative approach for protection against electric shock
7 Protection against thermal incidents
7.1 Overload protection <\/td>\n<\/tr>\n\n 21<\/td>\n 7.2 Short-circuit protection
8 Requirements for vehicle power supply circuit
9 Owner’s manual
10 Test procedures
10.1 General
10.2 Continuity test for equipotential bonding <\/td>\n<\/tr>\n\n 22<\/td>\n 10.3 Isolation resistance measurements for voltage class B2 electric circuits
10.3.1 Preconditioning and conditioning
10.3.2 Isolation resistance measurements of the balance of electric circuits <\/td>\n<\/tr>\n\n 23<\/td>\n 10.3.3 Isolation resistance measurement of the voltage class B2 electric power sources <\/td>\n<\/tr>\n \n 25<\/td>\n 10.3.4 Isolation resistance measurement of entire electric circuits
10.4 Test for isolation resistance monitoring system
10.5 Touch current <\/td>\n<\/tr>\n\n 26<\/td>\n 10.6 Withstand voltage test
10.6.1 General
10.6.2 Preconditioning and conditioning <\/td>\n<\/tr>\n\n 27<\/td>\n 10.6.3 Test procedure
10.6.4 Test criteria
\uea0110.7 Withstand voltage test for electric power sources which are not de-energized
10.7.1 General <\/td>\n<\/tr>\n\n 28<\/td>\n 10.7.2 Preconditioning and conditioning
10.7.3 Test <\/td>\n<\/tr>\n\n 30<\/td>\n 10.7.4 Test criteria <\/td>\n<\/tr>\n \n 31<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Electrically propelled road vehicles. Safety specifications – Electrical safety<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2020<\/td>\n 32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":255827,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-255825","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/255825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/255827"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=255825"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=255825"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=255825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}