{"id":117945,"date":"2024-10-19T03:47:13","date_gmt":"2024-10-19T03:47:13","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-b229-2004-2\/"},"modified":"2024-10-24T22:36:49","modified_gmt":"2024-10-24T22:36:49","slug":"astm-b229-2004-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-b229-2004-2\/","title":{"rendered":"ASTM-B229 2004"},"content":{"rendered":"<\/p>\n
1.1 This specification covers concentric-lay-stranded conductors made from uncoated hard-drawn round copper wires in combination with hard-drawn round copper-clad steel wires, for general use as overhead electrical conductors.<\/p>\n
1.2 For the purpose of this specification, conductors are classified under the following type designations (see Fig 1):<\/p>\n
1.3 The SI values for density are regarded as the standard. For all other properties the inch-pound values are to be regarded as standard and the SI units may be approximate.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Ordering Information FIG. 1 <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | TABLE 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Material for Wires Joints Lay Construction Physical and Electrical Tests Density Mass and Resistance TABLE 2 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Variation in Area Finish Inspection Packaging and Shipping Marking Keywords TABLE 3 <\/td>\n<\/tr>\n | ||||||