{"id":409141,"date":"2024-10-20T05:34:08","date_gmt":"2024-10-20T05:34:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-62271-2092019a12022\/"},"modified":"2024-10-26T10:12:01","modified_gmt":"2024-10-26T10:12:01","slug":"bs-en-iec-62271-2092019a12022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-62271-2092019a12022\/","title":{"rendered":"BS EN IEC 62271-209:2019+A1:2022"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
7<\/td>\nBlank Page <\/td>\n<\/tr>\n
8<\/td>\nAnnex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
10<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
12<\/td>\nFOREWORD <\/td>\n<\/tr>\n
14<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
15<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
16<\/td>\n4 Normal and special service conditions
4.1 General
4.2 Normal service conditions
4.3 Special service conditions
5 Ratings
5.1 General <\/td>\n<\/tr>\n
17<\/td>\n5.2 Rated voltage of the equipment of the cable connection (Urm)
5.3 Rated insulation level (Ud, Up, Us)
5.4 Rated frequency (fr)
5.5 Rated continuous current (Ir)
5.6 Rated short-time withstand current (Ik)
5.7 Rated peak withstand current (Ip)
5.8 Rated duration of short circuit (tk) <\/td>\n<\/tr>\n
18<\/td>\n6 Design and construction
6.1 Gas and vacuum tightness
6.101 Limits of supply
6.101.1 General
6.101.2 Over-voltage protection and earthing <\/td>\n<\/tr>\n
19<\/td>\n6.102 Filling pressure of insulating gas in the cable connection enclosure
6.103 Pressure withstand requirements
6.104 Mechanical forces on cable terminations
Figure 1 \u2013 Operating pressure of the SF6 gas insulation in the cable connection enclosure <\/td>\n<\/tr>\n
20<\/td>\n6.105 Switchgear connection interface and cable termination connection interface
7 Type tests
7.1 General
7.2 Electrical type tests of cable terminations
7.2.1 General
7.2.2 Electrical type test of cable terminations in a single-phase enclosure
7.2.3 Electrical type test of cable termination in a three-phase enclosure
Figures <\/td>\n<\/tr>\n
21<\/td>\n7.2.4 Additional electrical type tests on the insulator to be installed by switchgear manufacturer (plug in cable termination)
7.3 Pressure test on the insulator of a cable termination
Tables
Table 1 \u2013 Test voltages for additional electrical type tests according to 7.2.4 <\/td>\n<\/tr>\n
22<\/td>\n7.4 Leak rate type test on the insulator of a cable termination
8 Routine tests
8.1 General
8.2 Pressure test
8.3 Visual inspection
9 Standard dimensions
9.1 General
9.2 Fluid-filled cable terminations <\/td>\n<\/tr>\n
23<\/td>\n9.3 Dry-type cable terminations
9.4 Three-phase cable connection enclosure
10 Information to be given with enquiries, tenders and orders
11 Rules for transport, storage, erection, service and maintenance
11.1 General <\/td>\n<\/tr>\n
24<\/td>\n11.2 Tests after cable system installation
12 Safety practices and constraints during installation of cable connection to switchgear
13 Influence of the product on the environment <\/td>\n<\/tr>\n
25<\/td>\nFigure 2 \u2013 Fluid-filled cable connection assembly \u2013 Typical arrangement <\/td>\n<\/tr>\n
26<\/td>\nFigure 3 \u2013 Fluid-filled cable connection \u2013 Assembly dimensions <\/td>\n<\/tr>\n
27<\/td>\nFigure 4 \u2013 Dry-type cable connection assembly \u2013 Typical arrangement <\/td>\n<\/tr>\n
28<\/td>\nFigure 5 \u2013 Dry-type cable connection assembly \u2013 Assembly dimensions <\/td>\n<\/tr>\n
29<\/td>\nAnnex A (informative) Mechanical forces applied on the flange of the cable connection enclosure
A.1 General
A.2 Recommendation when connecting cable systems to switchgear <\/td>\n<\/tr>\n
30<\/td>\nTable A.1 \u2013 Moment and forces applied on the flange of the cable connection enclosure attached to the cable termination during normal operation <\/td>\n<\/tr>\n
31<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

High-voltage switchgear and controlgear – Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV – Fluid-filled and extruded insulation cables – Fluid-filled and dry-type cable terminations<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2022<\/td>\n32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":409150,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[516,2641],"product_tag":[],"class_list":{"0":"post-409141","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-130-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/409141","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/409150"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=409141"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=409141"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=409141"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}