{"id":276113,"date":"2024-10-19T18:34:53","date_gmt":"2024-10-19T18:34:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62135-22015-tc\/"},"modified":"2024-10-25T15:00:49","modified_gmt":"2024-10-25T15:00:49","slug":"bs-en-62135-22015-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62135-22015-tc\/","title":{"rendered":"BS EN 62135-2:2015 – TC"},"content":{"rendered":"

IEC 62135-2:2015 is applicable to equipment for resistance welding and allied processes which are connected to mains supplies with rated voltages up to 1 000 V a.c. r.m.s. This standard does not define safety requirements. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – update of the applicable limits related to the updated reference to CISPR 11; – exclusion of the use of narrow band relaxations for RF emission limits; – update of the applicable limits for harmonics and flicker related to the updated reference to IEC 61000-3-11 and IEC 61000-3-12; – update of the requirements for voltage dips related to the updated reference to IEC 61000-4-11 and IEC 61000-4-34; – inclusion of symbols to indicate the RF equipment class and restrictions for use; – inclusion of EM field immunity test for frequency from 1,4 GHz to 2,7 GHz; – inclusion of emission limits for class B resistance welding equipment magnetic fields between 150 kHz and 30 MHz.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
48<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
50<\/td>\nFOREWORD <\/td>\n<\/tr>\n
52<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
54<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
55<\/td>\n4 General test requirements
4.1 Test conditions
4.2 Measuring instruments
4.3 Artificial mains network
4.4 Voltage probe
4.5 Antennas
5 Test set-up for emission and immunity
5.1 General requirements <\/td>\n<\/tr>\n
56<\/td>\n5.2 Ancillary equipment
6 Emission tests
6.1 Classification of equipment
Figures
Figure 1 \u2013 Test position for H field measurement <\/td>\n<\/tr>\n
57<\/td>\n6.2 Test conditions <\/td>\n<\/tr>\n
58<\/td>\n6.3 Emission limits <\/td>\n<\/tr>\n
59<\/td>\n7 Immunity tests
7.1 Tests applicability <\/td>\n<\/tr>\n
60<\/td>\n7.2 Test conditions
7.3 Immunity performance criteria <\/td>\n<\/tr>\n
61<\/td>\n7.4 Immunity levels
Tables
Table 1 \u2013 Immunity levels \u2013 Enclosure
Table 2 \u2013 Immunity levels \u2013 AC input power port <\/td>\n<\/tr>\n
62<\/td>\n8 Documentation for the purchaser\/user
Table 3 \u2013 Immunity levels \u2013 Ports for measurement and control <\/td>\n<\/tr>\n
64<\/td>\nAnnex A (informative) Limits
A.1 General
A.2 Mains terminal disturbance voltage limits
A.3 Electromagnetic radiation disturbance limits
Table A.1 \u2013 Mains terminal disturbance voltage limits, idle state
Table A.2 \u2013 Mains terminal disturbance voltage limits, load conditions <\/td>\n<\/tr>\n
65<\/td>\nTable A.3 \u2013 Electromagnetic radiation disturbance limits, idle state
Table A.4 \u2013 Electromagnetic radiation disturbance limits, load conditions <\/td>\n<\/tr>\n
66<\/td>\nA.4 Harmonic current limits
Table A.5 \u2013 Magnetic field emission limits for Class B equipment
Table A.6 \u2013 Maximum permissible harmonic current for
\nequipment with input current I1cc \u2264 16 A <\/td>\n<\/tr>\n
67<\/td>\nTable A.7 \u2013 Current emission limits for equipment with 16 A < I1cc \u2264 75 A
\nother than balanced three-phase equipment
Table A.8 \u2013 Current emission limits for
\nbalanced three-phase equipment with input current 16 A < I1cc \u2264 75 A
Table A.9 \u2013 Current emission limits for balanced three-phase equipment
\nwith input current 16 A < I1cc \u2264 75 A under specified conditions <\/td>\n<\/tr>\n
68<\/td>\nA.5 Limits for voltage fluctuations and flicker
Table A.10 \u2013 Current emission limits for balanced three-phase equipment
\nwith I1cc \u2264 75 A under specified conditions (d, e, f) <\/td>\n<\/tr>\n
69<\/td>\nTable A.11 \u2013 Limits for resistance welding equipment I1cc \u2264 75 A <\/td>\n<\/tr>\n
70<\/td>\nAnnex B (informative) Symbols
Table B.1 \u2013 Symbols to describe EMC properties <\/td>\n<\/tr>\n
71<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Tracked Changes. Resistance welding equipment – Electromagnetic compatibility (EMC) requirements<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n74<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":276115,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-276113","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/276113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/276115"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=276113"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=276113"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=276113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}