{"id":252386,"date":"2024-10-19T16:39:43","date_gmt":"2024-10-19T16:39:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62271-12017\/"},"modified":"2024-10-25T11:58:54","modified_gmt":"2024-10-25T11:58:54","slug":"bs-en-62271-12017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62271-12017\/","title":{"rendered":"BS EN 62271-1:2017"},"content":{"rendered":"
This part of IEC 62271<\/span> <\/span> applies to AC switchgear and controlgear designed for indoor and\/or outdoor installation and for operation at service frequencies up to and including 60 Hz and having rated voltages above 1 000 V.<\/p>\n This document applies to all high-voltage switchgear and controlgear except as otherwise specified in the relevant IEC standards for the particular type of switchgear and controlgear.<\/p>\n For the use of this document, high-voltage is defined as the rated voltage above 1 000 V. However, the term medium voltage is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV.<\/p>\n<\/div>\n High-voltage switchgear and controlgear – Common specifications for alternating current switchgear and controlgear<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n National foreword <\/td>\n<\/tr>\n \n 11<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 17<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 20<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 21<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 23<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 24<\/td>\n 3.1 General terms and definitions <\/td>\n<\/tr>\n \n 27<\/td>\n 3.2 Assemblies of switchgear and controlgear
3.3 Parts of assemblies
3.4 Switching devices
3.5 Parts of switchgear and controlgear <\/td>\n<\/tr>\n\n 31<\/td>\n 3.6 Operational characteristics of switchgear and controlgear <\/td>\n<\/tr>\n \n 32<\/td>\n 3.6.5 Terms and definitions relative to pressure (or density)
3.6.6 Terms and definitions relating to gas and vacuum tightness <\/td>\n<\/tr>\n\n 34<\/td>\n 3.6.7 Terms and definitions relating to liquid tightness
3.7 Characteristic quantities <\/td>\n<\/tr>\n\n 35<\/td>\n 3.8 Index of definitions <\/td>\n<\/tr>\n \n 37<\/td>\n 4 Normal and special service conditions
4.1 Normal service conditions
4.1.1 General
4.1.2 Indoor switchgear and controlgear <\/td>\n<\/tr>\n\n 38<\/td>\n 4.1.3 Outdoor switchgear and controlgear
4.2 Special service conditions
4.2.1 General
4.2.2 Altitude <\/td>\n<\/tr>\n\n 39<\/td>\n 4.2.3 Exposure to pollution
4.2.4 Temperature and humidity
4.2.5 Exposure to abnormal vibrations, shock or tilting <\/td>\n<\/tr>\n\n 40<\/td>\n 4.2.6 Wind speed
4.2.7 Other parameters
5 Ratings
5.1 General
5.2 Rated voltage (Ur)
5.2.1 General
5.2.2 Range I for rated voltages of 245\u00a0kV and below <\/td>\n<\/tr>\n\n 41<\/td>\n 5.2.3 Range II for rated voltages above 245\u00a0kV
5.3 Rated insulation level (Ud, Up, Us) <\/td>\n<\/tr>\n\n 42<\/td>\n Tables
Table\u00a01 \u2013 Rated insulation levels for rated voltages of range I, series I <\/td>\n<\/tr>\n\n 43<\/td>\n Table 2 \u2013 Rated insulation levels for rated voltages of range I, series II (based on current practice in some countries, including US) <\/td>\n<\/tr>\n \n 44<\/td>\n Table\u00a03 \u2013 Rated insulation levels for rated voltages of range II <\/td>\n<\/tr>\n \n 45<\/td>\n 5.4 Rated frequency (fr)
5.5 Rated continuous current (Ir)
5.6 Rated short-time withstand current (Ik)
Table\u00a04 \u2013 Additional rated insulation levels for range II, basedon current practice in some countries, including US <\/td>\n<\/tr>\n\n 46<\/td>\n 5.7 Rated peak withstand current (Ip)
5.8 Rated duration of short-circuit (tk)
5.9 Rated supply voltage of auxiliary and control circuits (Ua)
5.9.1 General
5.9.2 Rated supply voltage (Ua)
Table\u00a05 \u2013 Peak factors for rated peak withstand current <\/td>\n<\/tr>\n\n 47<\/td>\n 5.10 Rated supply frequency of auxiliary and control circuits
5.11 Rated pressure of compressed gas supply for controlled pressure systems
Table\u00a06 \u2013 Direct current voltage
Table\u00a07 \u2013 Alternating current voltage <\/td>\n<\/tr>\n\n 48<\/td>\n 6 Design and construction
6.1 Requirements for liquids in switchgear and controlgear
6.2 Requirements for gases in switchgear and controlgear
6.3 Earthing of switchgear and controlgear
6.4 Auxiliary and control equipment and circuits
6.4.1 General <\/td>\n<\/tr>\n\n 49<\/td>\n 6.4.2 Protection against electric shock
6.4.3 Components installed in enclosures <\/td>\n<\/tr>\n\n 51<\/td>\n Table\u00a08 \u2013 Auxiliary contact classes <\/td>\n<\/tr>\n \n 52<\/td>\n 6.5 Dependent power operation
6.6 Stored energy operation
6.6.1 General
Figures
Figure 1 \u2013 Examples of classes of contacts <\/td>\n<\/tr>\n\n 53<\/td>\n 6.6.2 Energy storage in gas receivers or hydraulic accumulators
6.6.3 Energy storage in springs (or weights)
6.6.4 Manual charging
6.6.5 Motor charging
6.6.6 Energy storage in capacitors
6.7 Independent unlatched operation (independent manual or power operation) <\/td>\n<\/tr>\n\n 54<\/td>\n 6.8 Manually operated actuators
6.9 Operation of releases
6.9.1 General
6.9.2 Shunt closing release
6.9.3 Shunt opening release
6.9.4 Capacitor operation of shunt releases <\/td>\n<\/tr>\n\n 55<\/td>\n 6.9.5 Under-voltage release
6.10 Pressure\/level indication
6.10.1 Gas pressure
6.10.2 Liquid level
6.11 Nameplates
6.11.1 General
6.11.2 Application <\/td>\n<\/tr>\n\n 56<\/td>\n Table\u00a09 \u2013 Nameplate information <\/td>\n<\/tr>\n \n 57<\/td>\n 6.12 Locking devices
6.13 Position indication
6.14 Degrees of protection provided by enclosures
6.14.1 General
6.14.2 Protection of persons against access to hazardous parts and protection of the equipment against ingress of solid foreign objects (IP coding)
6.14.3 Protection against ingress of water (IP coding)
6.14.4 Protection against mechanical impact under normal service conditions (IK\u00a0coding) <\/td>\n<\/tr>\n\n 58<\/td>\n 6.15 Creepage distances for outdoor insulators
6.16 Gas and vacuum tightness
6.16.1 General
6.16.2 Controlled pressure systems for gas
6.16.3 Closed pressure systems for gas <\/td>\n<\/tr>\n\n 59<\/td>\n 6.16.4 Sealed pressure systems
6.17 Tightness for liquid systems
6.17.1 General
6.17.2 Leakage rates
6.18 Fire hazard (flammability)
6.19 Electromagnetic compatibility (EMC) <\/td>\n<\/tr>\n\n 60<\/td>\n 6.20 X-ray emission
6.21 Corrosion
6.22 Filling levels for insulation, switching and\/or operation
7 Type tests
7.1 General
7.1.1 Basics
7.1.2 Information for identification of test objects <\/td>\n<\/tr>\n\n 61<\/td>\n 7.1.3 Information to be included in type-test reports
7.2 Dielectric tests
7.2.1 General
7.2.2 Ambient air conditions during tests <\/td>\n<\/tr>\n\n 62<\/td>\n 7.2.3 Wet test procedure
7.2.4 Arrangement of the equipment <\/td>\n<\/tr>\n\n 63<\/td>\n 7.2.5 Criteria to pass the test
7.2.6 Application of the test voltage and test conditions <\/td>\n<\/tr>\n\n 64<\/td>\n Table\u00a010 \u2013 Test conditions in general case
Figure\u00a02 \u2013 Diagram of connections of a three-pole switching device <\/td>\n<\/tr>\n\n 65<\/td>\n Table\u00a011 \u2013 Power-frequency test conditions <\/td>\n<\/tr>\n \n 66<\/td>\n Table\u00a012 \u2013 Impulse test conditions
Table\u00a013 \u2013 Test conditions for the alternative method <\/td>\n<\/tr>\n\n 67<\/td>\n 7.2.7 Tests of switchgear and controlgear of Ur \u2264 245 kV
7.2.8 Tests of switchgear and controlgear of Ur > 245\u00a0kV <\/td>\n<\/tr>\n\n 68<\/td>\n 7.2.9 Artificial pollution tests for outdoor insulators
7.2.10 Partial discharge tests
7.2.11 Dielectric tests on auxiliary and control circuits
7.2.12 Voltage test as condition check <\/td>\n<\/tr>\n\n 69<\/td>\n 7.3 Radio interference voltage (RIV) test
7.4 Resistance measurement
7.4.1 Measurement of the resistance of auxiliary contacts class\u00a01 and class\u00a02
7.4.2 Measurement of the resistance of auxiliary contacts class\u00a03
7.4.3 Electrical continuity of earthed metallic parts test
7.4.4 Resistance measurement of contacts and connections in the main circuit as a condition check <\/td>\n<\/tr>\n\n 70<\/td>\n 7.5 Continuous current tests
7.5.1 Condition of the test object
7.5.2 Arrangement of the equipment <\/td>\n<\/tr>\n\n 71<\/td>\n 7.5.3 Test current and duration <\/td>\n<\/tr>\n \n 72<\/td>\n 7.5.4 Temperature measurement during test <\/td>\n<\/tr>\n \n 73<\/td>\n 7.5.5 Resistance of the main circuit
7.5.6 Criteria to pass test <\/td>\n<\/tr>\n\n 74<\/td>\n Table\u00a014 \u2013 Limits of temperature and temperature rise for various parts, materialsand dielectrics of high-voltage switchgear and controlgear <\/td>\n<\/tr>\n \n 77<\/td>\n 7.6 Short-time withstand current and peak withstand current tests
7.6.1 General
7.6.2 Arrangement of the equipment and of the test circuit <\/td>\n<\/tr>\n\n 78<\/td>\n 7.6.3 Test current and duration <\/td>\n<\/tr>\n \n 79<\/td>\n 7.6.4 Conditions of the test object after test
7.7 Verification of the protection
7.7.1 Verification of the IP coding
7.7.2 Verification of the IK coding <\/td>\n<\/tr>\n\n 80<\/td>\n 7.8 Tightness tests
7.8.1 General <\/td>\n<\/tr>\n\n 81<\/td>\n 7.8.2 Controlled pressure systems for gas
7.8.3 Closed pressure systems for gas
Table\u00a015 \u2013 Permissible leakage rates for gas systems <\/td>\n<\/tr>\n\n 82<\/td>\n 7.8.4 Sealed pressure systems
7.8.5 Liquid tightness tests
7.9 Electromagnetic compatibility tests (EMC)
7.9.1 Emission tests <\/td>\n<\/tr>\n\n 83<\/td>\n Figure\u00a03 \u2013 Diagram of a test circuit for the radio interference voltage test <\/td>\n<\/tr>\n \n 85<\/td>\n 7.9.2 Immunity tests on auxiliary and control circuits <\/td>\n<\/tr>\n \n 86<\/td>\n Table\u00a016 \u2013 Application of voltages at the fast transient\/burst test
Table\u00a017 \u2013 Application of voltage at the damped oscillatory wave test <\/td>\n<\/tr>\n\n 87<\/td>\n 7.9.3 Additional EMC tests on auxiliary and control circuits
Table\u00a018 \u2013 Assessment criteria for transient disturbance immunity <\/td>\n<\/tr>\n\n 88<\/td>\n 7.10 Additional tests on auxiliary and control circuits
7.10.1 General
7.10.2 Functional tests
7.10.3 Verification of the operational characteristics of auxiliary contacts <\/td>\n<\/tr>\n\n 89<\/td>\n 7.10.4 Environmental tests <\/td>\n<\/tr>\n \n 90<\/td>\n 7.10.5 Dielectric test
7.11 X-radiation test for vacuum interrupters
7.11.1 General requirements <\/td>\n<\/tr>\n\n 92<\/td>\n 7.11.2 Test voltage and measurement procedure
7.11.3 Acceptance criteria
Figure\u00a04 \u2013 Test location of radiation survey instrument <\/td>\n<\/tr>\n\n 93<\/td>\n 8 Routine tests
8.1 General
8.2 Dielectric test on the main circuit <\/td>\n<\/tr>\n\n 94<\/td>\n 8.3 Tests on auxiliary and control circuits
8.3.1 Inspection of auxiliary and control circuits, and verification of conformity to the circuit diagrams and wiring diagrams
8.3.2 Functional tests
8.3.3 Verification of protection against electrical shock
8.3.4 Dielectric tests
8.4 Measurement of the resistance of the main circuit <\/td>\n<\/tr>\n\n 95<\/td>\n 8.5 Tightness test
8.5.1 General
8.5.2 Controlled pressure systems for gas
8.5.3 Closed pressure systems for gas
8.5.4 Sealed pressure systems
8.5.5 Liquid tightness tests
8.6 Design and visual checks <\/td>\n<\/tr>\n\n 96<\/td>\n 9 Guide to the selection of switchgear and controlgear (informative)
9.1 General
9.2 Selection of rated values
9.3 Cable-interface considerations
9.4 Continuous or temporary overload due to changed service conditions
9.5 Environmental aspects
9.5.1 Service conditions
9.5.2 Clearances affected by service conditions
9.5.3 High humidity <\/td>\n<\/tr>\n\n 97<\/td>\n 9.5.4 Solar radiation
10 Information to be given with enquiries, tenders and orders (informative)
10.1 General
10.2 Information with enquiries and orders <\/td>\n<\/tr>\n\n 98<\/td>\n 10.3 Information with tenders <\/td>\n<\/tr>\n \n 99<\/td>\n 11 Transport, storage, installation, operating instructions and maintenance
11.1 General
11.2 Conditions during transport, storage and installation
11.3 Installation
11.3.1 General
11.3.2 Unpacking and lifting <\/td>\n<\/tr>\n\n 100<\/td>\n 11.3.3 Assembly
11.3.4 Mounting
11.3.5 Connections
11.3.6 Information about gas and gas mixtures for controlled and closed pressure systems <\/td>\n<\/tr>\n\n 101<\/td>\n 11.3.7 Final installation inspection
11.3.8 Basic input data by the user
11.3.9 Basic input data by the manufacturer <\/td>\n<\/tr>\n\n 102<\/td>\n 11.4 Operating instructions
11.5 Maintenance
11.5.1 General
11.5.2 Information about fluids and gas to be included in maintenance manual
11.5.3 Recommendations for the manufacturer <\/td>\n<\/tr>\n\n 103<\/td>\n 11.5.4 Recommendations for the user <\/td>\n<\/tr>\n \n 104<\/td>\n 11.5.5 Failure report <\/td>\n<\/tr>\n \n 105<\/td>\n 12 Safety
12.1 General <\/td>\n<\/tr>\n\n 106<\/td>\n 12.2 Precautions by manufacturers
12.3 Precautions by users
13 Influence of the product on the environment <\/td>\n<\/tr>\n\n 108<\/td>\n Annexes
Annex A (normative) Identification of test objects
A.1 General
A.2 Data
A.3 Drawings <\/td>\n<\/tr>\n\n 110<\/td>\n Annex B (informative) Determination of the equivalent RMS value of a short-time current during a short-circuit of a given duration
Figure\u00a0B.1 \u2013 Determination of short-time current <\/td>\n<\/tr>\n\n 111<\/td>\n Annex C (normative) Method for the weatherproofing test for outdoor switchgear and controlgear <\/td>\n<\/tr>\n \n 112<\/td>\n Figure\u00a0C.1 \u2013 Arrangement for weatherproofing test <\/td>\n<\/tr>\n \n 113<\/td>\n Figure\u00a0C.2 \u2013 Nozzle for weatherproofing test <\/td>\n<\/tr>\n \n 114<\/td>\n Annex D (informative) References for auxiliary and control circuit components
Table\u00a0D.1 \u2013 List of reference documents for auxiliary and control circuit components (1 of 2) <\/td>\n<\/tr>\n\n 116<\/td>\n Annex E (normative) Tolerances on test quantities during tests <\/td>\n<\/tr>\n \n 117<\/td>\n Table\u00a0E.1 \u2013 Tolerances on test quantities for type test <\/td>\n<\/tr>\n \n 119<\/td>\n Annex F (informative) Information and technical requirements to be given with enquiries, tenders and orders
F.1 General
F.2 Normal and special service conditions (refer to Clause\u00a04) <\/td>\n<\/tr>\n\n 120<\/td>\n F.3 Ratings (refer to Clause 5)
F.4 Design and construction (refer to Clause 6) <\/td>\n<\/tr>\n\n 121<\/td>\n F.5 System information
F.6 Documentation for enquiries and tenders <\/td>\n<\/tr>\n\n 122<\/td>\n Annex G (informative) List of symbols <\/td>\n<\/tr>\n \n 123<\/td>\n Annex H (informative) Electromagnetic compatibility on site <\/td>\n<\/tr>\n \n 124<\/td>\n Annex I (informative) List of notes concerning certain countries <\/td>\n<\/tr>\n \n 125<\/td>\n Annex J (informative) Extension of validity of type tests
J.1 General
J.2 Dielectric tests
J.3 Short-time withstand current tests
J.4 Continuous current test <\/td>\n<\/tr>\n\n 126<\/td>\n J.5 Electromagnetic immunity test on auxiliary and control circuits
J.6 Environmental tests on auxiliary and control circuits <\/td>\n<\/tr>\n\n 127<\/td>\n Annex K (informative) Exposure to pollution
K.1 General
K.2 Pollution levels
K.3 Minimum requirements for switchgear <\/td>\n<\/tr>\n\n 128<\/td>\n Table\u00a0K.1 \u2013 Environmental examples by site pollution severity (SPS) class
Table\u00a0K.2 \u2013 Minimum nominal specific creepage distance by pollution level <\/td>\n<\/tr>\n\n 129<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2017<\/td>\n 134<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":252395,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[516,2641],"product_tag":[],"class_list":{"0":"post-252386","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-130-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/252386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/252395"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=252386"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=252386"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=252386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}