{"id":139782,"date":"2024-10-19T08:06:36","date_gmt":"2024-10-19T08:06:36","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/mn-minnesotaconservationcodeforexistingbuildings-2015\/"},"modified":"2024-10-25T00:19:53","modified_gmt":"2024-10-25T00:19:53","slug":"mn-minnesotaconservationcodeforexistingbuildings-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/mn\/mn-minnesotaconservationcodeforexistingbuildings-2015\/","title":{"rendered":"MN MinnesotaConservationCodeforExistingBuildings 2015"},"content":{"rendered":"
This is a soft cover fully integrated custom Minnesota code based on the 2012 International Existing Building Code\u00ae . This code also includes Minnesota chapter 1300 Administration. Effective date: January 24, 2015<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 2015 MINNESOTA CONSERVATION CODE FOR EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | MINNESOTA DEPARTMENT OF LABOR & INDUSTRY <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | IMPORTANT DISCLAIMER <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | PREFACE <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | EFFECTIVE USE OF THE INTERNATIONAL EXISTING BUILDING CODE <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 2015 MINNESOTA BUILDING CODE ADMINISTRATION 1300.0010 ADMINISTRATION 1300.0020 TITLE 1300.0030 PURPOSE AND APPLICATION 1300.0040 SCOPE <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 1300.0050 CHAPTERS OF MINNESOTA STATE BUILDING CODE 1300.0060 OPTIONAL ADMINISTRATION 1300.0070 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 1300.0080 CODE ADOPTION AND AMENDMENTS 1300.0090 DEPARTMENT OF BUILDING SAFETY 1300.0110 DUTIES AND POWERS OF BUILDING OFFICIAL <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 1300.0120 PERMITS <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 1300.0130 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 1300.0140 VIOLATIONS 1300.0150 VIOLATIONS, PENALTY 1300.0160 FEES <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 1300.0170 STOP WORK ORDER 1300.0180 UNSAFE BUILDINGS OR STRUCTURES <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 1300.0190 TEMPORARY STRUCTURES AND USES 1300.0210 INSPECTIONS <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 1300.0215 PLUMBING 1300.0220 CERTIFICATE OF OCCUPANCY <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 1300.0225 MAINTENANCE 1300.0230 BOARD OF APPEALS <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 1300.0240 DISCLAIMER CLAUSE 1300.0250 SEVERABILITY <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 2015 MINNESOTA CONSERVATION CODE FOR EXISTING BUILDINGS 1311.0010 ADOPTION BY REFERENCE OF THE INTERNATIONAL EXISTING BUILDING CODE 1311.0020 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL CODES <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | CHAPTER 1 SCOPE AND ADMINISTRATION – DELETED <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | CHAPTER 3 COMPLIANCE METHODS SECTION 301 COMPLIANCE METHODS TABLE 301.1.4.1 PERFORMANCE CRITERIA FOR IBC\u2014LEVEL SEISMIC FORCES OCCUPANCY <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | TABLE 301.1.4.2 PERFORMANCE CRITERIA FOR REDUCED IBC\u2014LEVEL SEISMIC FORCES RISK CATEGORY <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | CHAPTER 4 PRESCRIPTIVE COMPLIANCE METHOD SECTION 401 GENERAL SECTION 402 ADDITIONS <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | SECTION 403 ALTERATIONS <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | SECTION 404 REPAIRS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | SECTION 405 FIRE ESCAPES TABLE 405.4 DIMENSIONS FOR EXISTING AND REPLACEMENT FIRE ESCAPE STAIRS SECTION 406 GLASS REPLACEMENT SECTION 407 CHANGE OF OCCUPANCY TABLE 407.1 LIFE SAFETY AND FIRE RISK <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | SECTION 408 HISTORIC BUILDINGS SECTION 409 MOVED STRUCTURES SECTION 410 ACCESSIBILITY FOR EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | CHAPTER 5 CLASSIFICATION OF WORK SECTION 501 GENERAL SECTION 502 REPAIRS SECTION 503 ALTERATION\u2014LEVEL 1 SECTION 504 ALTERATION\u2014LEVEL 2 SECTION 505 ALTERATION\u2014LEVEL 3 SECTION 506 CHANGE OF OCCUPANCY SECTION 507 ADDITIONS SECTION 508 HISTORIC BUILDINGS SECTION 509 RELOCATED BUILDINGS <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | CHAPTER 6 REPAIRS SECTION 601 GENERAL SECTION 602 BUILDING ELEMENTS AND MATERIALS SECTION 603 FIRE PROTECTION SECTION 604 MEANS OF EGRESS SECTION 605 ACCESSIBILITY SECTION 606 STRUCTURAL <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | SECTION 607 ELECTRICAL SECTION 608 MECHANICAL <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | SECTION 609 PLUMBING <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | CHAPTER 7 ALTERATIONS\u2014LEVEL 1 SECTION 701 GENERAL SECTION 702 BUILDING ELEMENTS AND MATERIALS SECTION 703 FIRE PROTECTION SECTION 704 MEANS OF EGRESS SECTION 705 ACCESSIBILITY SECTION 706 STRUCTURAL <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | SECTION 707 ENERGY CONSERVATION <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | CHAPTER 8 ALTERATIONS\u2014LEVEL 2 SECTION 801 GENERAL SECTION 802 SPECIAL USE AND OCCUPANCY SECTION 803 BUILDING ELEMENTS AND MATERIALS <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | SECTION 804 FIRE PROTECTION <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | SECTION 805 MEANS OF EGRESS <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | SECTION 806 ACCESSIBILITY SECTION 807 STRUCTURAL SECTION 808 ELECTRICAL <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | SECTION 809 MECHANICAL SECTION 810 PLUMBING SECTION 811 ENERGY CONSERVATION <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | CHAPTER 9 ALTERATIONS\u2014LEVEL 3 SECTION 901 GENERAL SECTION 902 SPECIAL USE AND OCCUPANCY SECTION 903 BUILDING ELEMENTS AND MATERIALS <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | SECTION 904 FIRE PROTECTION SECTION 905 MEANS OF EGRESS SECTION 906 ACCESSIBILITY SECTION 907 STRUCTURAL <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | SECTION 908 ENERGY CONSERVATION <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | CHAPTER 10 CHANGE OF OCCUPANCY SECTION 1001 GENERAL SECTION 1002 SPECIAL USE AND OCCUPANCY SECTION 1003 BUILDING ELEMENTS AND MATERIALS SECTION 1004 FIRE PROTECTION SECTION 1005 MEANS OF EGRESS SECTION 1006 ACCESSIBILITY SECTION 1007 STRUCTURAL <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | SECTION 1008 ELECTRICAL <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | SECTION 1009 MECHANICAL SECTION 1010 PLUMBING SECTION 1011 OTHER REQUIREMENTS SECTION 1012 CHANGE OF OCCUPANCY CLASSIFICATION <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | TABLE 1012.4 MEANS OF EGRESS HAZARD CATEGORIES TABLE 1012.5 HEIGHTS AND AREAS HAZARD CATEGORIES <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | TABLE 1012.6 EXPOSURE OF EXTERIOR WALLS HAZARD CATEGORIES <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | CHAPTER 11 ADDITIONS SECTION 1101 GENERAL SECTION 1102 HEIGHTS AND AREAS SECTION 1103 STRUCTURAL <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | SECTION 1104 SMOKE ALARMS IN OCCUPANCY GROUPS R AND I-1 SECTION 1105 ACCESSIBILITY SECTION 1106 ENERGY CONSERVATION <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | CHAPTER 12 HISTORIC BUILDINGS SECTION 1201 GENERAL SECTION 1202 REPAIRS SECTION 1203 FIRE SAFETY <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | SECTION 1204 ALTERATIONS SECTION 1205 CHANGE OF OCCUPANCY <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | SECTION 1206 STRUCTURAL <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | CHAPTER 13 RELOCATED OR MOVED BUILDINGS SECTION 1301 GENERAL SECTION 1302 REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | CHAPTER 14 PERFORMANCE COMPLIANCE METHODS SECTION 1401 GENERAL <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | EQUATION 14-1 EQUATION 14-2 EQUATION 14-3 <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | EQUATION 14-4 TABLE 1401.6.3 COMPARTMENTATION VALUES TABLE 1401.6.4 SEPARATION VALUES <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | TABLE 1401.6.5 CORRIDOR WALL VALUES TABLE 1401.6.6(1) VERTICAL OPENING PROTECTION VALUE TABLE 1401.6.6(2) CONSTRUCTION-TYPE FACTOR EQUATION 14-5 <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | TABLE 1401.6.8 AUTOMATIC FIRE DETECTION VALUES TABLE 1401.6.9 FIRE ALARM SYSTEM VALUES TABLE 1401.6.10 SMOKE CONTROL VALUES <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | TABLE 1401.6.11 MEANS OF EGRESS VALUESa TABLE 1401.6.12 DEAD-END VALUES <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | EQUATION 14-6 TABLE 1401.6.14 ELEVATOR CONTROL VALUES TABLE 1401.6.15 MEANS-OF-EGRESS EMERGENCY LIGHTING VALUES TABLE 1401.6.16 MIXED OCCUPANCY VALUESa <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | TABLE 1401.6.17 SPRINKLER SYSTEM VALUES TABLE 1401.6.18 STANDPIPE SYSTEM VALUES <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | TABLE 1401.6.19 INCIDENTAL USE AREA VALUESa TABLE 1401.8 MANDATORY SAFETY SCORESa <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | TABLE 1401.7 SUMMARY SHEET-BUILDING CODE <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | TABLE 1401.9 EVALUATION FORMULASa <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | IBC CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION SECTION 3301 GENERAL SECTION 3302 CONSTRUCTION SAFEGUARDS SECTION 3303 DEMOLITION SECTION 3304 SITE WORK <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | SECTION 3305 SANITARY SECTION 3306 PROTECTION OF PEDESTRIANS TABLE 3306.1 PROTECTION OF PEDESTRIANS <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | SECTION 3307 PROTECTION OF ADJOINING PROPERTY SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY SECTION 3309 FIRE EXTINGUISHERS SECTION 3310 MEANS OF EGRESS SECTION 3311 STANDPIPES <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | SECTION 3312 AUTOMATIC SPRINKLER SYSTEM SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | CHAPTER 16 REFERENCED STANDARDS ASCE\/SEI ASHRAE ASME ASTM <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | DOC ICC NFPA <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | RESOURCE A GUIDELINES ON FIRE RATINGS OF ARCHAIC MATERIALS AND ASSEMBLIES INTRODUCTION PURPOSE <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | 1 FIRE-RELATED PERFORMANCE OF ARCHAIC MATERIALS AND ASSEMBLIES 1.1 FIRE PERFORMANCE MEASURES <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | 1.2 COMBUSTIBLE CONSTRUCTION TYPES 2 BUILDING EVALUATION 2.1 PRELIMINARY EVALUATION <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | FIGURE 1 PRELIMINARY EVALUATION FIELD NOTES <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | FIGURE 2 PRELIMINARY EVALUATION WORKSHEET <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | 2.2 FIRE RESISTANCE OF EXISTING BUILDING ELEMENTS 2.3 EFFECTS OF PENETRATIONS IN FIRE RESISTANT ASSEMBLIES 3 FINAL EVALUATION AND DESIGN SOLUTION <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | 3.1 THE EXPERIMENTAL APPROACH 3.2 THE THEORETICAL APPROACH HARMATHY’S TEN RULES <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | ILLUSTRATION OF HARMATHY\u2019S RULES EXAMPLE APPLICATION OF HARMATHY\u2019S RULES <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | 3.3 \u201cTHICKNESS DESIGN\u201d STRATEGY 3.4 EVALUATION OF DOORS <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | FIGURE 3 MODIFICATION DETAILS <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | 4 SUMMARY <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | APPENDIX INTRODUCTION RESOURCE A TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | PURPOSE AND PROCEDURE <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | SECTION I – WALLS FIGURE 1.1.1 MASONRY WALLS 0″ TO LESS THAN 4″ THICK TABLE 1.1.1 MASONRY WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | TABLE 1.1.1\u2014continued MASONRY WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | TABLE 1.1.1\u2014continued MASONRY WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | FIGURE 1.1.2 MASONRY WALLS 4″ TO LESS THAN 6″ THICK TABLE 1.1.2 MASONRY WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | TABLE 1.1.2\u2014continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | TABLE 1.1.2\u2014continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | TABLE 1.1.2\u2014continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | TABLE 1.1.2\u2014continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | TABLE 1.1.2\u2014continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | TABLE 1.1.2\u2014continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | FIGURE 1.1.3 MASONRY WALLS 6″ TO LESS THAN 8″ THICK TABLE 1.1.3 MASONRY WALLS 6″ TO LESS THAN 8″ THICK <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | TABLE 1.1.3\u2014continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | TABLE 1.1.3\u2014continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | TABLE 1.1.3\u2014continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | TABLE 1.1.3\u2014continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | FIGURE 1.1.4 MASONRY WALLS 8″ TO LESS THAN 10″ THICK TABLE 1.1.4 MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | TABLE 1.1.4\u2014continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | TABLE 1.1.4\u2014continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | TABLE 1.1.4\u2014continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | TABLE 1.1.4\u2014continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | TABLE 1.1.4\u2014continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | TABLE 1.1.4\u2014continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | TABLE 1.1.4\u2014continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | FIGURE 1.1.5 MASONRY WALLS 10″ TO LESS THAN 12″ THICK TABLE 1.1.5 MASONRY WALLS 10″ TO LESS THAN 12″ THICK <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | TABLE 1.1.5\u2014continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | TABLE 1.1.5\u2014continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | TABLE 1.1.5\u2014continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | FIGURE 1.1.6 MASONRY WALLS 12″ TO LESS THAN 14″ THICK TABLE 1.1.6 MASONRY WALLS 12″ TO LESS THAN 14″ THICK <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | TABLE 1.1.6\u2014continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | TABLE 1.1.6\u2014continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | TABLE 1.1.6\u2014continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | TABLE 1.1.6\u2014continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | TABLE 1.1.6\u2014continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | FIGURE 1.1.7 MASONRY WALLS 14″ OR MORE THICK TABLE 1.1.7 MASONRY WALLS 14″ OR MORE THICK <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | TABLE 1.1.7\u2014continued MASONRY WALLS 14″ OR MORE THICK <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | TABLE 1.1.7\u2014continued MASONRY WALLS 14″ OR MORE THICK <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | FIGURE 1.2.1 METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK TABLE 1.2.1 METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | TABLE 1.2.1\u2014continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | TABLE 1.2.1\u2014continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | TABLE 1.2.1\u2014continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | FIGURE 1.2.2 METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK TABLE 1.2.2 METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | TABLE 1.2.2\u2014continued METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | TABLE 1.2.3 METAL FRAME WALLS 6″ TO LESS THAN 8″ THICK <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | TABLE 1.2.4 METAL FRAME WALLS 8″ TO LESS THAN 10″ THICK <\/td>\n<\/tr>\n | ||||||
160<\/td>\n | TABLE 1.3.1 WOOD FRAME WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | FIGURE 1.3.2 WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK TABLE 1.3.2 WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | TABLE 1.3.2\u2014continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | TABLE 1.3.2\u2014continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | TABLE 1.3.2\u2014continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | TABLE 1.3.2\u2014continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | TABLE 1.3.2\u2014continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | TABLE 1.3.2\u2014continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
168<\/td>\n | TABLE 1.3.2\u2014continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | TABLE 1.3.3 WOOD FRAME WALLS 6″ TO LESS THAN 8″ THICK TABLE 1.4.1 MISCELLANEOUS MATERIALS WALLS 0″ TO LESS THAN 4″ THICK <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | TABLE 1.4.2 MISCELLANEOUS MATERIALS WALLS 4″ TO LESS THAN 6″ THICK <\/td>\n<\/tr>\n | ||||||
171<\/td>\n | FIGURE 1.5.1 FINISH RATINGS\u2014INORGANIC MATERIALS TABLE 1.5.1 FINISH RATINGS\u2014INORGANIC MATERIALS <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | TABLE 1.5.1\u2014continued FINISH RATINGS\u2014INORGANIC MATERIALS TABLE 1.5.2 FINISH RATINGS\u2014ORGANIC MATERIALS <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | SECTION II -COLUMNS TABLE 2.1.1 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 0″ TO LESS THAN 6″ <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | FIGURE 2.1.2 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″ TABLE 2.1.2 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | TABLE 2.1.2\u2014continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | TABLE 2.1.2\u2014continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | TABLE 2.1.3 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 12″ TO LESS THAN 14″ <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | TABLE 2.1.4 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 14″ TO LESS THAN 16″ <\/td>\n<\/tr>\n | ||||||
179<\/td>\n | FIGURE 2.1.5 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″ TABLE 2.1.5 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″ <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | TABLE 2.1.5\u2014continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″ <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | TABLE 2.1.6 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 18″ TO LESS THAN 20″ <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | FIGURE 2.1.7 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″ TABLE 2.1.7 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″ <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | TABLE 2.1.7\u2014continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″ TABLE 2.1.8 HEXAGONAL REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 12″ TO LESS THAN 14″ <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | TABLE 2.1.9 HEXAGONAL REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 14″ TO LESS THAN 16″ TABLE 2.1.10 HEXAGONAL REINFORCED CONCRETE COLUMNS DIAMETER\u201416″ TO LESS THAN 18″ TABLE 2.1.11 HEXAGONAL REINFORCED CONCRETE COLUMNS DIAMETER\u201420″ TO LESS THAN 22″ <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | TABLE 2.2 ROUND CAST IRON COLUMNS <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | FIGURE 2.3 STEEL COLUMNS-GYPSUM ENCASEMENTS TABLE 2.3 STEEL COLUMNS\u2014GYPSUM ENCASEMENTS <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | TABLE 2.3\u2014continued STEEL COLUMNS\u2014GYPSUM ENCASEMENTS TABLE 2.4 TIMBER COLUMNS MINIMUM DIMENSION TABLE 2.5.1.1 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION LESS THAN 6″ <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | TABLE 2.5.1.2 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS 6″ TO LESS THAN 8″ THICK <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | FIGURE 2.5.1.3 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″ TABLE 2.5.1.3 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″ <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | TABLE 2.5.1.3\u2014continued STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″ <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | FIGURE 2.5.1.4 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″ TABLE 2.5.1.4STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | TABLE 2.5.1.4\u2014continued STEEL COLUMNS\u2014CONCRETE ENCASEMENTSMINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | TABLE 2.5.1.4\u2014continued STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | TABLE 2.5.1.4\u2014continued STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | FIGURE 2.5.1.5 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″ TABLE 2.5.1.5 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″ <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | TABLE 2.5.1.5 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″ <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | FIGURE 2.5.1.6 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″ TABLE 2.5.1.6 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″ <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | TABLE 2.5.1.6\u2014continued STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″ <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | TABLE 2.5.1.7 STEEL COLUMNS\u2014CONCRETE ENCASEMENTS MINIMUM DIMENSION 16″ TO LESS THAN 18″ TABLE 2.5.2.1 STEEL COLUMNS\u2014BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | TABLE 2.5.2.2 STEEL COLUMNS\u2014BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″ TABLE 2.5.2.3 STEEL COLUMNS\u2014BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″ <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | TABLE 2.5.3.1 STEEL COLUMNS\u2014PLASTER ENCASEMENTS MINIMUM DIMENSION 6″ TO LESS THAN 8″ TABLE 2.5.3.2 STEEL COLUMNS\u2014PLASTER ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″ TABLE 2.5.4.1 STEEL COLUMNS\u2014MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 6″ TO LESS THAN 8″ <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | TABLE 2.5.4.2 STEEL COLUMNS\u2014MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″ TABLE 2.5.4.3 STEEL COLUMNS\u2014MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″ TABLE 2.5.4.4 STEEL COLUMNS\u2014MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″ <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | SECTION III FLOOR\/CEILING ASSEMBLIES FIGURE 3.1 FLOOR\/CEILING ASSEMBLIES\u2014REINFORCED CONCRETE TABLE 3.1 FLOOR\/CEILING ASSEMBLIES\u2014REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | TABLE 3.1\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | TABLE 3.1\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | TABLE 3.1\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | TABLE 3.1\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | TABLE 3.1\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | FIGURE 3.2 FLOOR\/CEILING ASSEMBLIES\u2014STEEL STRUCTURAL ELEMENTS TABLE 3.2 FLOOR\/CEILING ASSEMBLIES\u2014STEEL STRUCTURAL ELEMENTS <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | TABLE 3.2\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014STEEL STRUCTURAL ELEMENTS <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | TABLE 3.2\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014STEEL STRUCTURAL ELEMENTS <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | TABLE 3.2\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014STEEL STRUCTURAL ELEMENTS <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | TABLE 3.2\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014STEEL STRUCTURAL ELEMENTS <\/td>\n<\/tr>\n | ||||||
214<\/td>\n | TABLE 3.2\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014STEEL STRUCTURAL ELEMENTS <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | FIGURE 3.3 FLOOR\/CEILING ASSEMBLIES\u2014WOOD JOIST TABLE 3.3 FLOOR\/CEILING ASSEMBLIES\u2014WOOD JOIST <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | TABLE 3.3\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014WOOD JOIST <\/td>\n<\/tr>\n | ||||||
217<\/td>\n | TABLE 3.3\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014WOOD JOIST <\/td>\n<\/tr>\n | ||||||
218<\/td>\n | TABLE 3.3\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014WOOD JOIST <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | FIGURE 3.4 FLOOR\/CEILING ASSEMBLIES\u2014HOLLOW CLAY TILE WITH REINFORCED CONCRETE TABLE 3.4 FLOOR\/CEILING ASSEMBLIES\u2014HOLLOW CLAY TILE WITH REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | TABLE 3.4\u2014continued FLOOR\/CEILING ASSEMBLIES\u2014HOLLOW CLAY TILE WITH REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
221<\/td>\n | TABLE 3.4\u2014continued FLOOR\/CEILING ASSEMBLIES-HOLLOW CLAY TILE WITH REINFORCED CONCRETE <\/td>\n<\/tr>\n | ||||||
222<\/td>\n | SECTION IV BEAMS TABLE 4.1.1 REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
223<\/td>\n | TABLE 4.1.1\u2014continued REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
224<\/td>\n | TABLE 4.1.1\u2014continued REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
225<\/td>\n | TABLE 4.1.2 REINFORCED CONCRETE BEAMS DEPTH 12″ TO LESS THAN 14″ <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | TABLE 4.1.2\u2014continued REINFORCED CONCRETE BEAMS DEPTH 12″ TO LESS THAN 14″ <\/td>\n<\/tr>\n | ||||||
227<\/td>\n | TABLE 4.1.3 REINFORCED CONCRETE BEAMS DEPTH 14″ TO LESS THAN 16″ <\/td>\n<\/tr>\n | ||||||
228<\/td>\n | TABLE 4.2.1 REINFORCED CONCRETE BEAMS\u2014UNPROTECTED DEPTH 10″ TO LESS THAN 12″ TABLE 4.2.2 STEEL BEAMS\u2014CONCRETE PROTECTION DEPTH 10″ TO LESS THAN 12″ <\/td>\n<\/tr>\n | ||||||
229<\/td>\n | SECTION V DOORS FIGURE 5.1 RESISTANCE OF DOORS TO FIRE EXPOSURE TABLE 5.1 RESISTANCE OF DOORS TO FIRE EXPOSURE <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | TABLE 5.1\u2014continued RESISTANCE OF DOORS TO FIRE EXPOSURE <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | TABLE 5.1\u2014continued RESISTANCE OF DOORS TO FIRE EXPOSURE <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | BIBLIOGRAPHY <\/td>\n<\/tr>\n | ||||||
239<\/td>\n | INDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Minnesota Conservation Code for Existing Buildings<\/b><\/p>\n |