BSI PD IEC TS 62607-4-7:2018

$142.49

Nanomanufacturing. Key control characteristics – Nano-enabled electrical energy storage. Determination of magnetic impurities in anode nanomaterials, ICP-OES method

Published By Publication Date Number of Pages
BSI 2018 24
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC TS 62607 provides a method for the determination of magnetic impurities in anode nanomaterials for energy storage devices using an Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES), including test overview, reagents, apparatus, test procedures, test results and test report.

This document applies to the determination of the total content of magnetic impurities (iron, cobalt, chromium, and nickel) ≥ 0,02 mg/kg which can be attracted by magnet.

PDF Catalog

PDF Pages PDF Title
2 undefined
4 CONTENTS
6 FOREWORD
8 INTRODUCTION
9 1 Scope
2 Normative references
3 Terms and definitions
10 4 Overview of the measurement
5 Reagents
5.1 Nitric acid
5.2 Hydrochloric acid
5.3 Nitrohydrochloric acid
5.4 Ethanol
5.5 Argon gas
5.6 Standard solutions
5.6.1 Iron standard solution
5.6.2 Cobalt standard solution,
5.6.3 Chromium standard solution,
5.6.4 Nickel standard solution,
6 Apparatus
6.1 ICP-OES
11 6.2 Conical flask
6.3 Sample tank
6.4 Magnet
6.5 Electronic balance
6.6 Scroll equipment
6.7 Ultrasonic cleaning equipment
6.8 Heating device
7 Preparation of series of standard solutions
Tables
Table 1 –Recommended test wavelengths for the determination of magnetic impurities
12 8 Test procedure
8.1 Cleaning the magnet
8.2 Test sample
8.3 Attraction of magnetic impurities
8.4 Remove nonmagnetic impurities
Table 2 – Correspondence of the measured mass to the untapped bulk density of the sample
13 8.5 Extraction of magnetic impurities
8.6 Preparation of blank sample
8.7 Test
9 Data analysis and calculation of results
Table 3 – Instrument operating parameters
14 10 Test report
15 Annex A (informative)Diagram of the scroll device
Figures
Figure A.1 – Diagram of sample tank on the rolling device
16 Annex B (informative)Magnet removal method
Figure B.1 – Diagram of magnet removal
17 Annex C (informative)Case study
C.1 Preparation of series of standard solutions
C.2 Cleaning the magnet
C.3 Weighing sample
Figure C.1 – Procedure for cleaning the magnet
18 C.4 Attraction of magnetic impurities
C.5 Remove nonmagnetic impurities
Figure C.2 – Procedure for weighing sample
Figure C.3 – Procedure for attraction of magnetic impurities
19 C.6 Extraction of magnetic impurities
C.7 Test
Figure C.4 – Procedure for removing nonmagnetic impurities
Figure C.5 – Procedure for extraction of magnetic impurities
20 C.8 Identify the uncertainty sources
Table C.1 – Test results of magnetic impurities
21 Annex D (informative)Validation of the attraction procedure
D.1 Experimental samples
D.2 Experimental procedure
D.3 Experimental results and conclusion
Table D.1 – Test results of magnetic impurities
22 Bibliography