BSI PD IEC TS 62271-304:2019
$142.49
High-voltage switchgear and controlgear – Classification of indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV related to the use in special service conditions with respect to condensation and pollution
Published By | Publication Date | Number of Pages |
BSI | 2019 | 30 |
This part of IEC 62271, which is a Technical Specification, applies to indoor enclosed switchgear and controlgear complying with IEC 62271-200 and IEC 62271-201, intended to be used in special service conditions with respect to condensation and pollution deviating from the normal service conditions specified in IEC 62271-1.
The test detailed in this document has been designed primarily to classify the electrical insulation performance of equipment having high-voltage electrical insulation exposed to indoor service conditions, mainly in presence of condensation. The assessment of mechanical components, such as mechanisms, interlocks and enclosure is also considered.
In this document, the term “equipment” is used in accordance with the scope for an “enclosed assembly of switchgear and controlgear” (see IEC 60050-441:2000, 441-12- 02).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | English CONTENTS |
6 | FOREWORD |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
9 | 4 Definition of indoor service conditions under condensation and pollution |
10 | 5 Classification of enclosed switchgear and controlgear 6 Test procedure for classification |
11 | Figures Figure 1 – Flow chart for classification testing procedure |
12 | 7 Test facilities and associated requirements 7.1 Climatic test room 7.2 Measurement and control requirements 7.3 Energizing facilities 7.4 Information to be included in the test report |
13 | 8 Arrangement of the equipment for test 9 Ageing test 9.1 Level 1 ageing test |
14 | 9.2 Level 2 ageing test Figure 2 – Climatic conditions for ageing test for level 1 and electrical assessment |
15 | 10 Electrical assessment after ageing test 10.1 General |
16 | 10.2 Criteria to pass the tests Figure 3 – Power-frequency voltage test sequences with high humidity after ageing test |
17 | Annexes Annex A (informative) Climatic test room Figure A.1 – Climatic test room |
18 | Annex B (informative) Typical indoor environments B.1 General B.2 Pollution |
19 | Tables Table B.1 – Examples of typical environments (IEC TS 60815-1, IEC 60721-3-3) |
20 | Table B.2 – Concentrations of some of the most important pollutants in different types of environments (Annex B of ISO 9223:2012 [8], IEC 60721-3-3) |
21 | Table B.3 – Deposits of some of the most important pollutants in different types of environments (Annex B of ISO 9223:2012 [8], IEC TS 60815-1, IEC 60721-3-3, IEC 60721-2-5[7]) |
22 | Annex C (informative) Typical precautions to improve indoor operating conditions C.1 General C.2 Precautions for operating room Table C.1 – Typical precautions to improve indoor operating conditions |
23 | Annex D (informative) Mechanical assessment |
24 | Annex E (informative) Pollution testing conditions, parameters, and procedure E.1 General E.2 Proposal for new classes E.3 Testing procedure E.3.1 Testing conditions |
25 | E.3.2 Testing parameters E.3.3 Testing procedure |
26 | Figure E.1 – Test cycle |
28 | Bibliography |