BS EN IEC 62522:2024
$167.15
Calibration of tuneable laser sources
Published By | Publication Date | Number of Pages |
BSI | 2024 | 44 |
IEC 62522:2024 is available as IEC 62522:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62552:2024 provides a stable and reproducible procedure to calibrate the wavelength and power output of a tuneable laser against reference instrumentation such as optical power meters and optical wavelength meters (including optical frequency meters) that have been previously traceably calibrated.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
6 | English CONTENTS |
8 | FOREWORD |
10 | INTRODUCTION |
11 | 1 Scope 2 Normative references 3 Terms, definitions, and abbreviated terms 3.1 Terms and definitions |
14 | 3.2 Abbreviated terms 4 Preparation for calibration 4.1 Organization 4.2 Traceability 4.3 Preparation |
15 | 4.4 Reference calibration conditions 5 Wavelength calibration 5.1 Overview Tables Table 1 – Source of uncertainty for wavelength calibration |
16 | 5.2 Wavelength calibration at reference conditions 5.2.1 Set-up 5.2.2 Calibration equipment 5.2.3 Procedure for wavelength calibration Figures Figure 1 – Measurement set-up for wavelength calibration |
17 | 5.2.4 Dependence on conditions Figure 2 – Measurement set-up for temperature dependence |
18 | Figure 3 – Measurement set-up for wavelength stability |
19 | 5.2.5 Uncertainty at reference conditions |
20 | 5.3 Wavelength calibration at operating conditions 5.3.1 General 5.3.2 Optical power dependence Figure 4 – Measurement set-up for optical power dependence |
21 | 5.3.3 Uncertainty at operating conditions |
22 | 6 Optical power calibration 6.1 Overview 6.2 Optical power calibration at reference conditions 6.2.1 Set-up Figure 5 – Measurement set-up for intrinsic optical power calibration Table 2 – Source of uncertainty for optical power calibration |
23 | 6.2.2 Calibration equipment 6.2.3 Procedure for power calibration at reference conditions |
24 | 6.2.4 Dependence on conditions Figure 6 – Measurement set-up for temperature dependence |
25 | Figure 7 – Measurement set-up for optical power stability |
26 | Figure 8 – Measurement set-up for connection repeatability/reproducibility |
27 | 6.2.5 Uncertainty at reference conditions 6.3 Optical power calibration at operating conditions 6.3.1 General |
28 | 6.3.2 Wavelength dependence Figure 9 – Measurement set-up for wavelength dependence |
29 | 6.3.3 Uncertainty at operating conditions 7 Documentation 7.1 Calibration data and uncertainty |
30 | 7.2 Calibration conditions |
31 | Annex A (normative) Mathematical basis for measurement uncertainty calculations A.1 General A.2 Type A evaluation of uncertainty |
32 | A.3 Type B evaluation of uncertainty |
33 | A.4 Determining the combined standard uncertainty A.5 Reporting |
34 | Annex B (informative) Other testing B.1 General B.2 Wavelength tuning resolution B.2.1 Set-up B.2.2 Testing equipment B.2.3 Testing procedure for determining wavelength resolution Figure B.1 – Measurement set-up for wavelength resolution |
35 | B.3 Optical power tuning resolution B.3.1 Set-up B.3.2 Testing equipment B.3.3 Testing procedure for optical power resolution Figure B.2 – Measurement set-up for optical power resolution setting test |
36 | B.4 Signal-to-source spontaneous emission ratio B.4.1 General B.4.2 Set-up B.4.3 Testing equipment B.4.4 Testing procedure for determining signal-to-source spontaneous emission ratio Figure B.3 – Measurement set-up for signal to total source spontaneous emission ratio |
37 | B.5 Side-mode suppression ratio B.5.1 General B.5.2 Set-up Figure B.4 – Measurement of the signal to spontaneous emission ratio Figure B.5 – Measurement set-up for the side-mode suppression ratio test |
38 | B.5.3 Testing equipment B.5.4 Testing procedure for determining the side-mode suppression ratio |
39 | Figure B.6 – Optical spectrum of tuneable laser source Figure B.7 – Measurement set-up for SMSR |
41 | Annex C (informative) Linear to dB scale conversion of uncertainties C.1 Definition of decibel C.2 Conversion of relative uncertainties |
43 | Bibliography |