BS EN IEC 62271-110:2023
$167.15
High-voltage switchgear and controlgear – Inductive load switching
Published By | Publication Date | Number of Pages |
BSI | 2023 | 36 |
IEC 62271-110:2023 is available as IEC 62271-110:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62271-110:2023 is applicable to AC switching devices designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching. It is applicable to switching devices (including circuit-breakers in accordance with IEC 62271-100) that are used to switch high?voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. This fifth edition cancels and replaces the fourth edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: references to IEC 62271-100 and IEC 62271-106 have been updated to the latest editions.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
6 | Blank Page |
7 | English CONTENTS |
9 | FOREWORD |
11 | 1 Scope 2 Normative references |
12 | 3 Terms and definitions |
13 | 4 Type tests 4.1 General 4.2 Miscellaneous provisions for inductive load switching tests |
14 | 4.3 High-voltage motor current switching tests 4.3.1 Applicability 4.3.2 General |
15 | 4.3.3 Characteristics of the supply circuits Figures Figure 1 ā Motor switching test circuit and summary of parameters |
16 | 4.3.4 Characteristics of the load circuit 4.3.5 Test voltage |
17 | 4.3.6 Test-duties 4.3.7 Test measurements 4.3.8 Behaviour and condition of switching device Tables Table 1 ā Test-duties at motor current switching tests |
18 | 4.3.9 Test report |
19 | 4.4 Shunt reactor current switching tests 4.4.1 Applicability Figure 2 ā Illustration of voltage transients at interruption of inductive current for first phase clearing in a three-phase non-effectively earthed circuit |
20 | 4.4.2 General 4.4.3 Test circuits Table 2 ā In-service load circuit configurations |
21 | Figure 3 ā Reactor switching test circuit ā Three-phase test circuit for in-service load circuit configurations 1 and 2 (Table 2) |
22 | Figure 4 ā Reactor switching test circuit ā Single-phase test circuit for in-service load circuit configurations 1, 2 and 4 (Table 2) |
23 | 4.4.4 Characteristics of the supply circuit 4.4.5 Characteristics of the connecting leads 4.4.6 Characteristics of the load circuits Figure 5 ā Reactor switching test circuit ā Three-phase test circuit for in-service load circuit configuration 3 (Table 2) |
24 | Table 3 ā Values of prospective transient recovery voltages ā Rated voltages 12 kV to 170 kV for effectively and non-effectively earthed systems ā Switching shunt reactors with isolated neutrals (Table 2: Inservice load circuit configuration 1) |
25 | Table 4 ā Values of prospective transient recovery voltages ā Rated voltages 100 kV to 1ā 200 kV for effectively earthed systems ā Switching shunt reactors withearthed neutrals (See Table 2: Inservice load circuit configuration 2) |
26 | Table 5 ā Values of prospective transient recovery voltages ā Rated voltages 12 kV to 52 kV for effectively and non-effectively earthed systems ā Switching shunt reactors with isolated neutrals (see Table 2: Inservice load circuit configuration 3) |
27 | Table 6 ā Values of prospective transient recovery voltages ā Rated voltages 12 kV to 52 kV for effectively and non-effectively earthed systems ā Switching shunt reactors with earthed neutrals (see Table 2: Inservice load circuit configuration 4) Table 7 ā Load circuit 1 test currents |
28 | 4.4.7 Earthing of the test circuit 4.4.8 Test voltage 4.4.9 Test-duties Table 8 ā Load circuit 2 test currents |
29 | Table 9 ā Test-duties for reactor current switching tests |
31 | Figure 6 ā Illustration of voltage transients at interruption of inductive current for a single-phase test |
32 | Annex A (normative) Calculation of t3 values |
34 | Bibliography |